Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 24 for “"Flattening Filter Free"”.
-
Respiratory-gated liver stereotactic radiotherapy in flattening filter free photon mode
… by using a higher dose rate, provided by flattening filter free (FFF) photon mode. To validate that increasing dose rate through removal of the flattening filter does not decrease cell kill, radiobiological experiments were carried out with three cell lines. Both the clonogenic survival …
-
Improved Target Coverage of Spinal Metastases Through The Use of Flattening Filter Free Beams
… local control and tumor recurrence at follow-up. Flattening Filter Free (FFF) photon beams have been shown to have lower out-of-field dose and sharper dose gradients when compared with conventionally flattened (FF) photon beams of similar energy; this sharp dose fall-off could potentially prove …
-
Flattening Filter Free photon beams for treatment of early-stage lung cancer: an investigation of peripheral dose
… SABR treatments for 10X, 6X, and 10X-FFF beams. Flattening Filter Free (FFF) radiotherapy photon beams exhibit high dose rates as compared to standard flattened photon beams. The high dose rates available with FFF beams make them ideal for high dose treatments, such as Volumetric Modulated Arc …
-
Developing a QA procedure for gated VMAT SABR treatments using 10 MV beam in flattening-filter free mode
… Arc Therapy (VMAT) using a 10 MV beam in Flattening Filter Free (FFF) mode. This method takes advantage of the high dose gradient region of SABR treatments to detect any inaccuracies in the performance of the Varian Real-time Position Manage- ment (RPM) gating system. This study involves …
-
Monte Carlo modelling of peripheral dose and risk of secondary malignancy in flattening-filter-free and 10 MV photon beams for paediatric radiotherapy
… radiotherapy treatment modes: 6MV flattened, 6MV flattening-filter-free (FFF) and 10MV FFF. To establish the clinical significance of the dose difference between the three modes, the risk of SMN as calculated by four different risk models was assessed for whole lung irradiation (WLI). The mixed …
-
Evaluation of The Effectiveness of Anisotropic Analytical Algorithm In Flattened and Flattening-Filter-Free Beams For High Energy Lung Dose Delivery Using The Radiological Physics Center Lung Phantom
… lung phantom using both flattened and flattening-filter-free high energy beams. Radiation treatment plans were developed following the Radiation Therapy Oncology Group and theRadiologicalPhysicsCenterguidelines for lung treatment using Stereotactic Radiation Body Therapy. The tumor was …
-
Absorbed dose in the build-up region in modern megavoltage photon radiotherapy
… to 6.2x20 cm². Secondly, we focussed on flattening filter-free linear accelerators, which currently face swift implementation into clinical practice because of their increased dose rate and reduction in head scatter compared to conventional designs. Our study demonstrated that build-up …
-
Dosimetric effects of removing the flattening filter in radiotherapy treatment units
… the dosimetric effects of removing the flattening filter from conventional C-arm medical linear accelerators. In conventional linear accelerators used for radiotherapy, a flattening filter is positioned in the beam line to provide a uniform lateral dose profile at a specified depth in …
-
Implementation of TG-351 Reference Dosimetry for a 6 MV Photon Beam in an MR-Guided Radiotherapy System
… used to perform reference dosimetry for a 6 MV flattening filter-free (FFF) photon beam from a Viewray MRIdian MR-Linac radiation therapy system. Beam quality determination, magnetic field correction factors, and radial profile corrections for FFF beams are included in the calculation for …
-
Unflattened Radiotherapy beams; characterisation, optimisation and application
The goal of this thesis was to investigate flattening filter free (FFF) beams produced by medical linear accelerators for radiotherapy applications, from their initial setup through to their clinical implementation. This was split into four sections that comprise the main experimental chapters of …
-
Optimising treatment outcomes using Stereotactic Body Radiotherapy (SBRT) for prostate cancer
… prostate SABR planning using flattened and flattening filter free (FFF) beams. A systematic review examined RISPC risk following prostate radiotherapy. A final study estimated RISPC risks following prostate SABR in comparison to other contemporary radiation techniques. Results: Prostate SABR …
-
Developing quality assurance procedures for gated volumetric modulated arc therapy in stereotactic ablative radiation therapy
… on a TrueBeam™ linear accelerator using a 10FFF (flattening filter free) beam and Varian’s real-time position management (RPM) system for respiratory gating. Two kinds of breathing patterns were used: free breathing (FB) and an interrupted (~5 s pause) end of exhale coached breathing (CB) pattern. …
-
Development of A New Independent Monte Carlo Dose Calculation Quality Assurance Audit to ol For Clinical Trials
… of Elekta 6MV and 10MV and Varian TrueBeam Flattening Filter Free (FFF) 6MV and FFF 10MV therapeutic x-ray beams were developed. The Monte Carlo technique, using the Dose Planning Method (DPM) algorithm, was used in radiation dose calculations. During validation calculations were compared to …
-
Radiation pneumonitis assessed in a mouse model of partial-body irradiation with minimal bone marrow sparing
… irradiated in a single fraction, using a 6 MV Flattening-Filter-Free beam on a Varian TrueBeam LINAC. The following experimental groups were assessed: (1) 8 Gy partial-body irradiation (PBI), sparing the tibiae, ankles, and feet plus an 8 Gy simultaneous-infield-boost (SIB) to the lung to …
-
Investigation of the dosimetric characteristics of X-ray beams in the range of 2.5 to 6 MV for intracranial Stereotactic Radiotherapy and Radiosurgery applications
… TrueBeam σε λειτουργία χωρίς φίλτρο επιπέδωσης (flattening filter free). Δημιουργήθηκαν phase spaces για δέσμες 2.5 MV-FFF, 4 MV-FFF και 6 MV-FFF, οι οποίες χρησιμοποιήθηκαν τόσο σε προσομοιώσεις ομοιωμάτων όσο και σε προσομοιώσεις ασθενών. Στο πρώτο μέρος, τα δοσιμετρικά χαρακτηριστικά κάθε …
-
Μελέτη της βελτιστοποίησης εξελιγμένων τεχνικών ακτινοθεραπείας με χρήση νανοσωματιδίων
… increase. For this purpose, a flattened and a flattening filter free 6 ΜV photon beam arising from the TrueBeam® linear accelerator was modelled in GATE platform. AuNPs of different sizes were arranged in clusters and distributed in different depths in a modelled water phantom. The clusters …
-
Quality Assurance Procedures Implementation for Varian TrueBeam
… LINAC includes 6x, 6xFFF (i.e., 6x without flattening filter known as flattening filter free), 10x, 10xFFF, 15x photon beams and 6e, 9e, 12e MeV electron beams. This system is also equipped with a 6 degree of freedom (DOF) couch, RapidArc, kV on board imager, MV portal imager and Cone Beam …
-
Monte Carlo investigation of the dosimetric impact of the presence of asymmetric air gaps on the ionization chamber response in MR-Linac quality control procedure
… και 1 × 1 cm2 του κλινικού συστήματος 1.5Τ/7MV flattening-filter-free της εταιρείας Elekta, με το όνομα Unity. Τα phase space files παρείχε ο κατασκευαστής. Ασύμμετρα χάσματα αέρα 0, 0.1, 0.3, 0.5 χιλιοστών εισήχθησαν μεταξύ των τοιχωμάτων των θαλάμων και του ομοιώματος. Οι προσομοιώσεις …
Page 1 of 2