Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 54 for “"Flip angle"”.
-
Optimized Variable Flip Angle Methods for Single Pool MRI Relaxometry
… many gradient echo techniques, such as Variable Flip Angle (VFA), Driven Equilibrium Single Pulse Observation of T1/2 (DESPOT), Muti-Parametric Mapping(MPM), etc, have been developed to infer tissue MR properties in clinically feasible times. However, a consensus regarding the accu-racy of each …
-
Gradient echo-based quantitative MRI of human brain at 7T : Mapping of T1, MT saturation and local flip angle
… emphasis is also put on mapping of the local flip angle. Primarily, qMRI is performed by the inversion of analytical signal equations, as opposed to numerical approaches.The process of implementing and modifying the dual flip angle (DFA) technique in conjunction with an MT-weighted GRE for 7T …
-
Magnetic Field Analysis of Asymmetric, High-Pass Imaging Structures Based on Theoretical Current Distributions
… 23.5% at most for measured values of the NMR flip angle . In the best case, for the circular symmetric structure, the predicted magnetic flux density values agree to within 7.4% at most for measured values of the NMR flip angle.
-
Characterization and compensation of physiological fluctuations in functional magnetic resonance imaging
… effect in cardiac-gated fMRI data incorporating flip angle estimated from fMRI dataset itself. Using an unscented Kalman filter, spatial maps of flip angle and T1 relaxation are estimated simultaneously from the cardiac-gated time series. Accounting for spatial variation in flip angle, the new …
-
A Magnetic Flux Density Control System for the Birdcage Resonator
… are presented that show a discrepancy in NMR flip angle produced by the APS and B1 feedback methods of 1.53 degrees for a desired NMR flip angle of 90 degrees.
-
Temperature mapping of particles during aseptic processing via magnetic resonance imaging
… aseptic processing were studied. A variable flip angle gradient echo sequence was initially tested. With this sequence T1 maps were obtained from two images acquired in sequence with a total imaging time of approximately 25 seconds. With a T1 vs temperature calibration, temperature …
-
High resolution imaging of tissue properties with optimized precision using Ultra High Field MRI
… semisolid component that have MT. The concept of flip angle does not apply for semisolid magnetization as it follows a different physics from the Bloch equation. Instead the semisolid magnetization saturates in a rate that depends on the root-mean-squared B+1 (Brms 1 ). We proposed a novel pTx …
-
Quantitative Determination of Chemical Processes by Dynamic Nuclear Polarization Enhanced Nuclear Magnetic Resonance Spectroscopy
… hyperpolarization is available. Using small flip angle pulse excitation, the hyperpolarization can still be divided into multiple scans. Based on this principle, a scheme is presented that allows reconstruction of indirect spectral dimensions similarly to conventional 2D NMR. Additionally, …
-
Artifact reduction in cardiac MRI in patients with varying heart rate
… of the artifacts through dynamic adaptation of flip angle and inversion time is proposed. The artifact reduction method was tested on the simulation and was found to reduce some artifacts, while enhancing others. If proved to work in practice, this method could contribute to improving image …
-
An 8 Channel Transmit-Receive RF Volume Coil for Magnetic Resonance Imaging
… Magnetic field simulations were compared to flip angle maps, comparing transmit fields, and receive sensitivities were compared to measured signal intensities. Full electronics characterization is described, and optimization was achieved by following the described design process. Proof of …
-
Inherent insensitivity to RF inhomogeneity in FLASH imaging
… an interesting observation that the fast low-angle shot (FLASH) sequence, which is often used for anatomic imaging and morphometric studies, can be insensitive to RF inhomogeneity when the same coil is used for both transmission and reception and a proper nominal flip angle is employed. …
-
Three-dimensional T1 quantification techniques for assessment of cartilage quality using dGEMRIC
… of B1 inhomogeneities and slab profile flip angle variations in the 3D-LL data. From in vivo and phantom measurements the methods were shown to be reliable, with T1 results that agreed very well to gold standard two-dimensional inversion recovery (2D-IR). A 3D variable flip angle …
-
B1 Mapping for Magnetic Resonance Imaging
… physics, followed by an introduction to B1 and flip-angle mapping in MRI (Chapters 1-3). Chapter 4 presents a careful statistical analysis of a recent and popular B1 mapping method, the Bloch-Siegert shift (BSS) method, along with a comparison of the technique to other common B1 mapping methods. …
-
T1 mapping and image reconstruction: examination for quantitative MRI
… for calculating T1 values, such as the dual-flip-angle (DFA) method. The last part of the thesis serves as a tutorial that introduces several basic steps that reconstruct an image from acquired raw data.
-
Appetite signals in the brain: High fructose corn syrup sweetened cola effects hypothalamic activity as measured by functional magnetic resonance imaging
… slice; echo time: 5ms; repetition time 40ms; flip angle: 40°; FOV: 210 mm; in-plane resolution: 1.6mm X 1.6mm). MANOVA revealed a statistically significant three-way interaction between time, volume and treatment when the model was weighted with either fasting insulin (p<0.0001) or fasting …
-
Novel Deep Learning Methods for Enhanced MRI Acquisition and Reconstruction
… in self-learning MRI. Optimized variable flip angle schemes for 3D Fast Spin Echo imaging are identified that balance signal-to-noise ratio (SNR) and the point-spread function. In vivo evaluations at ultra-high field demonstrate that these optimized schemes substantially reduce image …
-
Zero Quantum Nuclear Magnetic Resonance experiments utilizing a toroid cell and coil
… factors 1) B1 homogeneity, 2) B₀ homogeneity, 3) flip angle dependence, and 4) sensitivity. Finally, the two probes will be contrasted using spectral analysis in the spin-spin mapping of a simple molecule (nâ butanol) and a complex molecular system (taxol).
-
Magnetic Resonance Fingerprinting at Ultra-high Magnetic Fields
… varying the sequence parameters, such as flip angles, throughout a scan. The data is acquired as a highly undersampled dynamic image series, from which tissue parameters can be inferred with pattern recognition.<br/><br/>Long acquisition times, image quality and resolution are central …
-
Experimental Performance Study of a Lab-Scale Hydrokite System
… system power trends with respect to hydrofoil angles, boom flip angles, pivot-point location on hydrofoil, tow speed, and hydrofoil submerged depth. Single dimension parameter tests were done to determine the changes in average cycle power for the system as a function of a given parameter. …
-
Comparison of Delayed Contrast-Enhanced Magnetic Resonance Imaging of Myocardial Viability at 1.5 and 3 Tesla
… were performed to optimize the sequence for flip angle and inversion time, as well as to evaluate the influence of other image parameters that affected contrast. These theoretical results were validated experimentally with phantoms. In vivo post-contrast T1 measurements at 1.5T and 3T from …
Page 1 of 3