Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 29 for “"Floor Beam"”

  1. SEMI-RIGID BEAM-TO-BEAM COMPOSITE JOINT FOR LONG SPAN COMPOSITE FLOOR BEAM

    … out a series of experimental investigation on beam-to-beam composite joints (BBCJs) to evaluate their structural properties such as the rotational stiffness and moment resistance, and the test results were compared with the analytical predictions based on the component method in Eurocode 4. …

    nus Repository record for SEMI-RIGID BEAM-TO-BEAM COMPOSITE JOINT FOR LONG SPAN COMPOSITE FLOOR BEAM (opens in a new tab)

  2. Monotonic Testing of Steel Anchor Straps for Alternative Installation Methods in Wood Frame Shear Walls

    … alignment to connect a post above a particular floor of a building to a post below that floor may instead be bent and wrapped around a floor beam. Four specimens using steel straps were constructed and tested in order to simulate building situations. The experimental specimens had wooden posts …

    sjsu Repository record for Monotonic Testing of Steel Anchor Straps for Alternative Installation Methods in Wood Frame Shear Walls (opens in a new tab)

  3. Experimental and analytical study of the shear transfer in composite shallow cellular floor beams

    … transfer mechanism in composite shallow cellular floor beams. The shear transfer mechanism is different with the headed shear studs used in composite construction. The shear resisting properties and behaviour of the shear transfer mechanism has not been studied previously. Experimental and …

    city-london Repository record for Experimental and analytical study of the shear transfer in composite shallow cellular floor beams (opens in a new tab)

  4. Realistic fatigue assessment on historic riveted retrofitted railway bridges in Chile

    … railway bridges, particularly at stringer-to-floor-beam connections, which studies have identified as the most susceptible to fatigue. However, limited historical traffic data and structural details mean most assessments rely on the bridge's current state and standard loading models, which do …

    ucl Repository record for Realistic fatigue assessment on historic riveted retrofitted railway bridges in Chile (opens in a new tab)

  5. Fire safety design of composite slim floor structures

    … design method for composite steel-concrete slim floor structures was developed, including the characterization of fully-developed compartment fire curves and the equivalent fire exposure, temperature analysis of the composite structures, and the structural response analysis of composite slim …

    aalto Repository record for Fire safety design of composite slim floor structures (opens in a new tab)

  6. Hybrid masonry connector plate and headed stud small-scale wall testing

    … the CMU walls as a gravity member, the steel beams in the frames can be reduced resulting in a lower construction cost. In Type III Hybrid Masonry the CMU walls act as the web of a composite shear wall with the steel columns as boundary elements for columns. Drs. Ian Robertson and Gaur …

    hawaii Repository record for Hybrid masonry connector plate and headed stud small-scale wall testing (opens in a new tab)

  7. Development of the Design of Eccentrically Braced Frames with Replaceable Shear Links

    … (EBFs), the yielding link is coupled with the floor beam. This often results in oversized link elements, which leads to over-designed structures and foundations. In addition, the beams are expected to sustain significant damage through repeated inelastic deformations under design level …

    toronto-retro Repository record for Development of the Design of Eccentrically Braced Frames with Replaceable Shear Links (opens in a new tab)

  8. Multiaxial fatigue behavior and strengthening of riveted double-angle connections in steel bridges using prestressed CFRP rods

    … suffer from fatigue problems. Stringer-to-floor-beam double-angle bridge connections are among the most fatigue-prone details due to the many cyclic distortion-induced stresses from axle loads. Increasing service loads and corrosion put these components at a higher risk of fatigue cracking. …

    epfl Repository record for Multiaxial fatigue behavior and strengthening of riveted double-angle connections in steel bridges using prestressed CFRP rods (opens in a new tab)

  9. Fatigue damage evaluation of cutout details in steel bridges

    … are mostly found at rib-to-deck joints, rib-to-floor beam connections, butt weld connections, etc. In rib-to-floor beam connections, though the fatigue cracks initiated at welded joints and cutouts are both extensively observed, the latter attracts less attention, and its fatigue evaluation …

    aalto Repository record for Fatigue damage evaluation of cutout details in steel bridges (opens in a new tab)

  10. Analysis and rehabilitation of the 1882 wrought iron bridge

    … loading conditions. Parts of the top chord, floor beam, and diagonals were overstressed under the dead and pedestrian loads, and the bottom diagonals were overstressed under the wind load. Four lifting methods were analyzed for the bridge's relocation. The method considered the most efficient …

    alabama Repository record for Analysis and rehabilitation of the 1882 wrought iron bridge (opens in a new tab)

  11. Effect of a slab on the behavior of exterior beam to column connections

    … slabs are usually cast monolithically with the floor beams. The currently used recommendations for the design of beam to column connections for seismic loading, however, completely ignore the presence of the slab. Even though, previous studies have shown slabs to have a significant effect on the …

    rice Repository record for Effect of a slab on the behavior of exterior beam to column connections (opens in a new tab)

  12. Load rating analysis, field testing of steel railroad bridges - dailey branch bridges at mileposts 1.4 and 5.8

    … account. The bridge members including girders, floor beams, and stringers are analyzed for maximum bending moments and shears using RISA (Structural Analysis) software, in conjunction with MS-EXCEL calculations for load rating. The field-testing performed in August 2014, on these two bridges at …

    wvu Repository record for Load rating analysis, field testing of steel railroad bridges - dailey branch bridges at mileposts 1.4 and 5.8 (opens in a new tab)

  13. Behaviour of a semi-continuous beam-column connection for composite slim floors

    The flooring system with its connections to the supporting column significantly influences the technical quality and performance of the steel-concrete composite design and the overall economic viability of the construction. Expectations of technical and economic flexibility and cost-effectiveness …

    aalto Repository record for Behaviour of a semi-continuous beam-column connection for composite slim floors (opens in a new tab)

  14. Column design for axial compression and end rotation.

    … columns using flexible cap and base plates and floor beams that are either simply supported or continuous. The method is intended to be used with shallow floor construction with concrete or steel/concrete composite slabs in which the floor slab occupies the depth of the floor beams and is fully …

    whiterose Repository record for Column design for axial compression and end rotation. (opens in a new tab)

  15. An Experimental and analytical study of chevron braced frames with vertical slotted connections

    … was introduced between the top of the braces and floor beam above to prevent vertical load transfer to the beam and limit brace forces to the compressive resistance of the members. An experimental program was devised to study VSC chevron braced frame behaviour under quasi-static cyclic loading …

    ubc Repository record for An Experimental and analytical study of chevron braced frames with vertical slotted connections (opens in a new tab)

  16. Seismic Performance of Eccentrically Braced Frames Designed According to Canadian Seismic Provisions

    … to the inelastic activity of a small part of the floor beam called link. Current capacity design approach of EBFs is to confine the inelastic behavior of the frame primarily to the link such that other members remain essentially in elastic range. Limited research works are available in the …

    concordia

  17. Avaliação do comportamento estrutural de vigas mistas de slim floor com aberturas na alma

    … mesa superior do perfil de aço. Os sistemas slim floor são formados por Vigas de aço e lajes de diferentes tipos, integradas dentro do piso, proporcionando uma redução na altura total do sistema de piso. Contudo, ao reduzir a altura do sistema de piso a utilização dos conectores tipo pino com …

    brazil-ufv Repository record for Avaliação do comportamento estrutural de vigas mistas de slim floor com aberturas na alma (opens in a new tab)

  18. Continuing airworthiness policy and application to flying crane aircraft

    This project is part of a collaborative MSc training programme between the Aviation Industries of China (AVIC) and Cranfield University, aiming at enhancing the competitiveness of AVIC in both international and domestic aviation market through applying continuing airworthiness policies in the whole …

    cranfield Repository record for Continuing airworthiness policy and application to flying crane aircraft (opens in a new tab)

  19. Rekonstrukce skladovacího objektu

    Předmětem této bakalářské práce je rekonstrukce administrativní budovy v Třinci. Práce je rozdělena na dvě části: návrh a posouzení dřevěné konstrukce krovu nad celým půdorysem budovy na rozpětí přibližně 16 × 21 m a ocelové nosné konstrukce nástavby administrativní budovy na půdoryse 8 × 16,5 m. …

    brno-tech Repository record for Rekonstrukce skladovacího objektu (opens in a new tab)

Page 1 of 2