Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 39 for “"Flow Disturbance"”.

  1. COMPACT SPACE-FOLDED MULTI-RESONATOR DUCT SILENCER WITH BROADBAND NOISE REDUCTION AND MINIMAL FLOW DISTURBANCE

    … this structure allows for unobstructed fluid-flow through its center, resulting in a static fluid pressure drop across the device of only 14.5 Pa. In addition, due to the silencer’s configurable nature, the geometry can be tuned to meet acoustic and geometric requirements during the design. …

    rowan Repository record for COMPACT SPACE-FOLDED MULTI-RESONATOR DUCT SILENCER WITH BROADBAND NOISE REDUCTION AND MINIMAL FLOW DISTURBANCE (opens in a new tab)

  2. An Arrayed Hot-Film Sensor for Detection of Laminar Boundary-Layer Flow Disturbance Spatial Characteristics

    … research for the detection of crossflow or Gortler vortices. This sensor has been developed to detect spatial variations in heat transfer and velocity perturbations which are characteristic of crossflow or Gortler vortices. The sensor is ultimately intended for flight research …

    odu Repository record for An Arrayed Hot-Film Sensor for Detection of Laminar Boundary-Layer Flow Disturbance Spatial Characteristics (opens in a new tab)

  3. An analysis of the flow disturbance due to gaseous secondary injection into a rocket nozzle

    The flow disturbances in a supersonic rocket nozzle due to secondary injection have been analyzed by using an effective body approximation. The analysis is based upon a consideration of the momentum flux of the primary and secondary flows and the under-expansion of the momentum flux of the …

    vt Repository record for An analysis of the flow disturbance due to gaseous secondary injection into a rocket nozzle (opens in a new tab)

  4. Partially Closed Valve Effects on Electromagnetic Flow Meter Accuracy

    … even result in a depleted resource. Generally, flow meters need a flow profile to be fully developed so to optimizemeasurement accuracy. In order to produce accurate measurements, most flow meters require a straight section of pipe immediately upstream of the meter. The straight pipe helps to …

    utahstate Repository record for Partially Closed Valve Effects on Electromagnetic Flow Meter Accuracy (opens in a new tab)

  5. Heat transfer in nano/micro multi-component and complex fluids with applications to heat transfer enhancement

    Thermal properties of complex suspension flows are investigated using numerical computations. The objective is to develop an efficient and accurate computational method to investigate heat transport in suspension flows. The method presented here is based on solving the lattice Boltzmann equation …

    gatech Repository record for Heat transfer in nano/micro multi-component and complex fluids with applications to heat transfer enhancement (opens in a new tab)

  6. Aspects of sensory cues and propulsion in marine zooplankton hydrodynamic disturbances

    The hydrodynamic disturbances generated by two types of free-swimming, marine zooplankton were quantified experimentally in the laboratory with a novel, infrared Particle Image Velocimetry (PIV) system. The study consisted of three main parts: (1) the flow fields of free-swimming and tethered …

    gatech Repository record for Aspects of sensory cues and propulsion in marine zooplankton hydrodynamic disturbances (opens in a new tab)

  7. Simulation of Counterintuitive Pressure Drop in a Parallel Flow Design for a Specimen Basket for Use in the Advanced Test Reactor

    … Chaotic mixing produced some pressure drop. Flow disturbance related to flow rate caused a pressure drop at high flow rates when the fluid separated into each channel. The anomalous pressure drop was caused by the design of the test cap section.

    utahstate Repository record for Simulation of Counterintuitive Pressure Drop in a Parallel Flow Design for a Specimen Basket for Use in the Advanced Test Reactor (opens in a new tab)

  8. Development of a pressure transducer to measure the time-varying pressures generated in a radial face seal

    … to measure the fluid film pressure with minimum flow disturbance.</p><p>The method consisted of cementing a stainless steel foil piece over the entire stationary surface. The stationary piece had holes drilled through it so that a diaphragm was formed by the foil over the holes. The procedure for …

    ut-knoxville Repository record for Development of a pressure transducer to measure the time-varying pressures generated in a radial face seal (opens in a new tab)

  9. Stream Bank Erosion Trends and Sediment Contributions in a Southwestern Missouri River

    … stability, and reduce sediment supply. However, flow disturbance zones at channel bends along bedrock bluffs can enhance bar formation locally which can force lateral channel shifting and increased bank erosion rates.

    mo-state Repository record for Stream Bank Erosion Trends and Sediment Contributions in a Southwestern Missouri River (opens in a new tab)

  10. Fouling of stainless steel surfaces by heated whole milk : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Food Technology

    … surfaces and to determine the effects of mass flow rate and flow disturbance on the fouling of these surfaces. A pilot-scale fouling rig was designed and built to mimic the heat treatment methods and conditions that are currently used in large-scale processing plants. Whole milk was first …

    massey Repository record for Fouling of stainless steel surfaces by heated whole milk : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Food Technology (opens in a new tab)

  11. Measurement of Liquid Film in Annular Flow Using X-Ray Densitometry

    Two-phase annular flow film thickness is a crucial parameter in nuclear thermal hydraulics, yet conventional measurement techniques such as impedance probes may compromise accuracy by directly contacting and potentially disturbing the flow. Non-intrusive measurement methods are needed to provide …

    vt Repository record for Measurement of Liquid Film in Annular Flow Using X-Ray Densitometry (opens in a new tab)

  12. A Study of the Beginning Boundary Layer Influence on the Flow Field about a Two-Dimensional Automotive Model

    … a subsonic wind tunnel and its influence on the flow field about a two-dimensional automotive model. Hot film anemometer measurements were taken in the test section of the wind tunnel operating under various inlet configurations. The use of a splitter plate and modifications to the contour of the …

    ut-knoxville Repository record for A Study of the Beginning Boundary Layer Influence on the Flow Field about a Two-Dimensional Automotive Model (opens in a new tab)

  13. Computational study of red cell distribution in simple networks

    … across the vessel lumen is disturbed when blood flows through a junction. As the blood flows downstream from the junction, the RBC distribution "corrects" itself to regain its original symmetric character. A dispersion-type process has been used to model this rearrangement process in …

    unh-thes Repository record for Computational study of red cell distribution in simple networks (opens in a new tab)

  14. Study on high subsonic turbulent flow incipient separation and hole/boundary layer interaction

    … subsonic and transonic turbulent boundary layer flow caused by a ramp compression corner and a large single hole. These two problems were studied separately by wind tunnel experiments.</p><p>For flow over a two-dimensional ramp compression corner case, an experimental investigation to determine …

    ut-knoxville Repository record for Study on high subsonic turbulent flow incipient separation and hole/boundary layer interaction (opens in a new tab)

  15. Experimental Study of Shock Wave Interference Heating on a Cylindrical Leading Edge

    … mechanics of shock wave interference induced flow impingement on a cylindrical leading edge and the attendant surface pressure and heat flux distributions. The study has provided the first detailed heat transfer rate and pressure distributions for two-dimensional shock wave interference on a …

    odu Repository record for Experimental Study of Shock Wave Interference Heating on a Cylindrical Leading Edge (opens in a new tab)

  16. Seal inlet disturbance boundary conditions for rotordynamic models and influence of some off-design conditions on labyrinth rotordynamic instability

    … model was employed to compute the seal-inlet flow disturbance quantities. Seal inlet disturbance boundary condition correlations were proposed from the computed seal-inlet quantities using the important parameters. It was found that the cosine component of the seal-inlet swirl velocity …

    tamu Repository record for Seal inlet disturbance boundary conditions for rotordynamic models and influence of some off-design conditions on labyrinth rotordynamic instability (opens in a new tab)

  17. Modelling and Advanced Multivariable Control Strategies For a Pilot Scale Extractive Distillation Column

    … for various open loop steps in the reflux flow rate, feed flow rate, feed composition and reboiler duty. The nonlinear behaviour of the system was simulated by the models. A simple model for vapour liquid equilibrium (VLE) calculations was developed and its validity was proven.</p> <p>The …

    mcmaster Repository record for Modelling and Advanced Multivariable Control Strategies For a Pilot Scale Extractive Distillation Column (opens in a new tab)

  18. Cardiovascular manifestations of Marfan syndrome: insights from advanced cardiovascular magnetic resonance

    … <p>Comprehensive 3D visualisation of blood flow in the entire thoracic aorta of subjects with MFS was achieved using a time-resolved phase-contrast magnetic resonance technique with 3-directional velocity encoding (4D flow), demonstrating a high prevalence of major flow disturbance (87 ± …

    oxford Repository record for Cardiovascular manifestations of Marfan syndrome: insights from advanced cardiovascular magnetic resonance (opens in a new tab)

  19. DESIGN AND CONTROL OF A ROBOTIC SYSTEM TO ASSIST WITH MRI-GUIDED INTERVENTIONS

    … under beating-heart conditions is the disturbances generated by the blood flow patterns inside the heart. To address this issue, an analytic model is generated to predict the flow disturbance generated from the interaction between the blood flow and the surgical tool in the aortic valve …

    houston Repository record for DESIGN AND CONTROL OF A ROBOTIC SYSTEM TO ASSIST WITH MRI-GUIDED INTERVENTIONS (opens in a new tab)

  20. The Effects of Meter Orientation Downstream of a Short Radius Elbow on Electromagnetic Flow Meters

    Electromagnetic flowmeters (known as magnetic flow meters) are a widely used type of flowmeter. The accuracy of magnetic flow meters are a function of several factors, not the least of which is the flow condition inside the pipe. It has been shown that disturbances in the velocity profile affects …

    utahstate Repository record for The Effects of Meter Orientation Downstream of a Short Radius Elbow on Electromagnetic Flow Meters (opens in a new tab)

Page 1 of 2