Results

Showing 1 to 20 of 108 for “"Flow cells"”.

  1. Analytical Chemiluminescence in Microporous Membrane Flow Cells

    Microporous membrane chemiluminescence (CL) flow cells are presented as an advantageous method for chemical reagent and analyte mixing in continuous flow. The method adds simplicity, significant reagent economy and minimal sample contamination to the conventional advantages of analytical CL …

    uiuc Repository record for Analytical Chemiluminescence in Microporous Membrane Flow Cells (opens in a new tab)

  2. Tubular All Vanadium and Vanadium/Air Redox Flow Cells

    [ES] Un aumento de la generación de energía a partir de fuentes renovables (solar, eólica) requiere una alta flexibilidad de las redes eléctricas. En este sentido, las baterías de flujo redox de vanadio (BFRV) han demostrado una excelente capacidad para proporcionar dicha flexibilidad, mediante el …

    upv Repository record for Tubular All Vanadium and Vanadium/Air Redox Flow Cells (opens in a new tab)

  3. Chemiluminescent Determinations of Clinical Analytes Using Microporous Membrane Flow Cells

    … presented the use of microporous membrane flow cells for the chemiluminescent determinations of some of these species using flow injection analysis as an advantageous alternative to more classical methods of detection. The compounds studied were glucose, glactose, cholesterol (in both the …

    uiuc Repository record for Chemiluminescent Determinations of Clinical Analytes Using Microporous Membrane Flow Cells (opens in a new tab)

  4. AQUEOUS REDOX FLOW CELLS FOR LARGE-SCALE ENERGY STORAGE AND CONVERSION

    Aqueous redox flow cells (ARFCs) have exhibited unique advantages in the energy storage field. The ARFCs have excellent customizability and scalability due to their decoupled energy storage and power generation. However, the energy density of ARFCs is limited by the electrochemical stability window …

    nus Repository record for AQUEOUS REDOX FLOW CELLS FOR LARGE-SCALE ENERGY STORAGE AND CONVERSION (opens in a new tab) Download file for AQUEOUS REDOX FLOW CELLS FOR LARGE-SCALE ENERGY STORAGE AND CONVERSION (opens in a new tab)

  5. Using microscale flow cells to study the electrochemical reduction of carbon dioxide

    … in an alkaline, air-breathing laminar flow fuel cell as a function of electrode length, electrode arrangement, and flow rates. Higher current densities were achieved when using shorter electrodes. Furthermore, alternative electrode arrangements (aspect ratios and multiple electrodes in …

    uiuc Repository record for Using microscale flow cells to study the electrochemical reduction of carbon dioxide (opens in a new tab)

  6. Observations of displacement processes of residual oil by aqueous surfactant solutions in extended visual flow cells

    … was observed using thin section glass flow cells up to 2 feet in length filled with a consolidated cryolite grain matrix in conjunction with a color video camera and monitor. The systems were designed to address the maintenance of the structural integrity of tertiary oil banks in long …

    texas Repository record for Observations of displacement processes of residual oil by aqueous surfactant solutions in extended visual flow cells (opens in a new tab)

  7. REDOX FLOW CELLS BASED ON THERMALLY REGENERATIVE ELECTROCHEMICAL CYCLE FOR LOW-GRADE HEAT CONVERSION AND STORAGE

    … for a more sustainable society, several redox flow cells based on thermally regenerative electrochemical cycle (TREC) with improved thermoelectric efficiencies and enhanced power densities were reported. To demonstrate the practical applications of TREC, a membrane-free TREC flow cell was …

    nus Repository record for REDOX FLOW CELLS BASED ON THERMALLY REGENERATIVE ELECTROCHEMICAL CYCLE FOR LOW-GRADE HEAT CONVERSION AND STORAGE (opens in a new tab) Download file for REDOX FLOW CELLS BASED ON THERMALLY REGENERATIVE ELECTROCHEMICAL CYCLE FOR LOW-GRADE HEAT CONVERSION AND STORAGE (opens in a new tab)

  8. Understanding Formation and Transport of Amorphous Iron Oxyhydroxides in Porous Media using Microfluidic Flow Cells- a Novel Method to Study Freshwater Iron Cycling

    … with Fe (II) rich underlying ground water. The flow cell was constructed from Polydimethylsiloxane, (PDMS) a transparent, biologically inert silicone polymer which can be modified to represent the surface properties of natural porous media by oxygen plasma exposure. Our results demonstrated that …

    uconn-diss Repository record for Understanding Formation and Transport of Amorphous Iron Oxyhydroxides in Porous Media using Microfluidic Flow Cells- a Novel Method to Study Freshwater Iron Cycling (opens in a new tab)

  9. Multinode Acoustic Systems for High Throughput Cellular Analysis

    For decades, flow cytometry is used as the gold standard for cellular analyses as it measures multiple properties of single cells. Traditional flow cytometry uses the hydrodynamic focusing technique where the sheath fluid focuses cells in the sample into a narrow stream. Although such precise …

    unm Repository record for Multinode Acoustic Systems for High Throughput Cellular Analysis (opens in a new tab)

  10. An Electrochemical Immunoassay System for Measuring Circulating Protein Biomarkers of Pediatric Soft Tissue Sarcoma

    … care. The combination of inexpensive 3D-printed flow cells and electrochemical biosensors has recently emerged as a viable platform for low-cost, reliable biomarker measurements. Here, we report an electrochemical immunoassay system based on simple graphite electrode arrays, 3D-printed flow …

    etsu Repository record for An Electrochemical Immunoassay System for Measuring Circulating Protein Biomarkers of Pediatric Soft Tissue Sarcoma (opens in a new tab) Download PDF for An Electrochemical Immunoassay System for Measuring Circulating Protein Biomarkers of Pediatric Soft Tissue Sarcoma (opens in a new tab)

  11. Construction and application of an On-line Flow Cell ICP-OES setup for real time dissolution detection

    … design novel high-surface area, low volume flow cells were designed for high-throughput detection of chemical and electrochemical dissolution products of energy storage materials found in zinc-air batteries, including current collectors and bifunctional catalysts. Novel flow cells were …

    lancaster Download PDF for Construction and application of an On-line Flow Cell ICP-OES setup for real time dissolution detection (opens in a new tab)

  12. Near-infrared spectral imaging as a detection technique for organic materials in porous media

    … quantitative analysis of contaminant transport flow cells and of high-performance thin-layer chromatography (HPTLC) plates by near-infrared imaging spectroscopy. A solid-state, near-infrared imaging spectrometer was constructed for these studies. The spectrometer utilized an imaging quality …

    arizona-thes Repository record for Near-infrared spectral imaging as a detection technique for organic materials in porous media (opens in a new tab)

  13. Quantifying the adhesion strength of microalgae on polydimethylsiloxane surfaces

    … were quantified with two different types of flow cells employed for our studies. These two types of flow cells are microfluidic chips and a laser-cut flow cell chamber, which provide a high and low wall shear stress, respectively. A video analysis software was designed to automate all aspects …

    uvic Repository record for Quantifying the adhesion strength of microalgae on polydimethylsiloxane surfaces (opens in a new tab)

  14. Evaporative Lithographic Patterning of Colloidal Films

    Finally, fluid flow and pattern formation during evaporative lithographic patterning of non-aqueous colloidal films differ significantly from their aqueous counterparts. Evaporative cooling creates surface tension gradients that induce recirculating flows and a majority of the particles are …

    uiuc Repository record for Evaporative Lithographic Patterning of Colloidal Films (opens in a new tab)

  15. A framework for scalable CO₂ reduction : process modeling and techno-economics to identify performance and cost tradeoffs

    … membrane electrode assemblies and non-aqueous flow cells. Results highlight the importance of high selectivity for both downstream applications and overall process economics, emphasizing the need to decouple selectivity from single-pass conversion via electrolyzer redesign. The techno-economics …

    texas Repository record for A framework for scalable CO₂ reduction : process modeling and techno-economics to identify performance and cost tradeoffs (opens in a new tab)

  16. Ανάπτυξη μεθόδων χαρακτηρισμού μορφολογίας βιοϋμενίων: εφαρμογή σε περίπλοκες γεωμετρίες ροής

    … and monitoring their growth in complex flow geometries, such as those found in water distribution systems. To achieve this, innovative flow cells were designed and constructed to allow the formation of flow fields according to experimental requirements (including flow through a straight …

    greece Repository record for Ανάπτυξη μεθόδων χαρακτηρισμού μορφολογίας βιοϋμενίων: εφαρμογή σε περίπλοκες γεωμετρίες ροής (opens in a new tab)

  17. Experimental characterization of the Barree and Conway (2004) single-phase non-Darcy flow model in various hydraulic fracturing sands

    … investigate the effect of non-Darcy flow through fracturing sand and irregular shaped materials on the parameters of the Barree and Conway (2004) non-Darcy single-phase flow model. It also investigates the existence of the minimum permeability concept. Several modifications were made …

    colo-mines Repository record for Experimental characterization of the Barree and Conway (2004) single-phase non-Darcy flow model in various hydraulic fracturing sands (opens in a new tab)

  18. Investigation of the effect of rapid and slow external pH increases on Enterococcus faecalis biofilm grown on dentine.

    … or slow increases in external pH. Method: A flow cell apparatus was used to grow single species E. faecalis biofilm on dentine discs. Following four weeks growth in Todd Hewitt Broth (THB), flow cells were exposed to either a rapid or slow increase to pH 11.5 or 12.5 using pH buffered growth …

    adelaide Repository record for Investigation of the effect of rapid and slow external pH increases on Enterococcus faecalis biofilm grown on dentine. (opens in a new tab)

Page 1 of 6