Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"Flow circuit"”.

  1. Liquid Nitrogen Propulsion Systems for Automotive Applications: Calculation of Mechanical Efficiency of a Dual, Double-acting Piston Propulsion System

    … their respective mechanical efficiencies. The flow circuit for the entire system was analyzed by using flow circuit analysis software to determine pressure losses throughout the system at the required mass flow rates. The results of the piston simulation indicate that the two pistons analyzed …

    unt Repository record for Liquid Nitrogen Propulsion Systems for Automotive Applications: Calculation of Mechanical Efficiency of a Dual, Double-acting Piston Propulsion System (opens in a new tab)

  2. Simulation of a solar water heating system

    … using a solarimeter and thermosyphon mass flow rates were measured using a thermistor inserted into the flow circuit. Close correlation was obtained between predicted and experimental results. Daily efficiencies varied according to the times and quantities of hot water draw offs. The …

    cape-town Repository record for Simulation of a solar water heating system (opens in a new tab)

  3. Determining Suitability of Additive Manufacturing of Carotid Artery Geometry for Flow Phantom Construction

    … thesis investigates methods of simulating blood flow for clinical applications. Physical flow phantoms of simplified vessel structures with varying levels of stenosis based on the geometry of the human carotid artery were investigated. The potential for additive manufacturing to be involved in …

    dundee Repository record for Determining Suitability of Additive Manufacturing of Carotid Artery Geometry for Flow Phantom Construction (opens in a new tab) Download PDF for Determining Suitability of Additive Manufacturing of Carotid Artery Geometry for Flow Phantom Construction (opens in a new tab)

  4. Experimental study of fluid structure interaction effects on metal plates under fully developed laminar flow

    … of FSI between fully developed laminar flow and test section plate in an enclosed flow channel. Computational Fluid Dynamics (CFD) software was used to model laminar flow in a shallow rectangular duct to determine proper dimensions of the experimental apparatus. The FSI problem was then …

    nps Repository record for Experimental study of fluid structure interaction effects on metal plates under fully developed laminar flow (opens in a new tab)

  5. An improved chip-level test generation algorithm

    … algorithms. The algorithm accepts data flow circuit descriptions written in a subset of VHDL. A fault model which defines faults for the VHDL statements is applied to determine fault cases. Test generation requirements of fault sensitization, value justification, and fault effect …

    vt Repository record for An improved chip-level test generation algorithm (opens in a new tab)

  6. Hyper-gates Framework for Straight-line Programs and Their Applications in Nonlinear Algebra

    … an algorithm to be mapped as a predictable data-flow circuit, enabling massive parallelization. Nonlinear systems are foundational to science and engineering, with their solutions studied with algebraic geometry and approximated by numerical algebraic geometry algorithms like homotopy …

    gatech Repository record for Hyper-gates Framework for Straight-line Programs and Their Applications in Nonlinear Algebra (opens in a new tab)

  7. A methodology for the prediction of non-volatile particulate matter from aircraft gas turbine engine

    … prediction environment consists of a Combustor Flow Circuit model, Statistical Distribution Model with the unmixedness curve, Chemical Reactor Networks (CRN), and Soot Evaluation Model. The integrated prediction environment developed with the proposed methodology demonstrates good predictability …

    gatech Repository record for A methodology for the prediction of non-volatile particulate matter from aircraft gas turbine engine (opens in a new tab)

  8. The design, fabrication, and testing of a portable arteriovenous fluid warming system

    … control system that monitors and modulates fuel flow to control the temperature of the exiting fluid. The fuel-powered fluid warmer is a significant improvement over existing technology found currently in the field. A fuel-based rewarming system would allow trauma victims to receive treatment …

    texas Repository record for The design, fabrication, and testing of a portable arteriovenous fluid warming system (opens in a new tab) Restricted access

  9. Adhesion of retrovirally transduced endothelial cells to expanded polytetrafluoroethylene vascular grafts

    … under <em>in vivo</em> and <em>in vitro</em> flow conditions. This study addresses the issue of retrovirally transduced EC adhesion to expanded polytetrafluoroethylene (ePTFE) vascular grafts. Human umbilical vein endothelial cells (HUVEC) were retrovirally transduced with the neoR gene (LN) …

    ut-knoxville Repository record for Adhesion of retrovirally transduced endothelial cells to expanded polytetrafluoroethylene vascular grafts (opens in a new tab)

  10. JOINT MICROFLUIDIC ASSESSMENT OF LOCAL SHEAR AND SHEAR HISTORICAL EFFECTS ON THROMBOSIS: APPLICATIONS TO HEART-ASSIST DEVICES AND HYPERINFLAMMATORY STATES

    … devices is elevated shear rates throughout the flow circuit. Blood components rely on deviations from physiological shear to sense bleedings events and trigger thrombosis. As a result, thrombotic complications are common in patients with circulatory support devices, and even more so when …

    cornell Repository record for JOINT MICROFLUIDIC ASSESSMENT OF LOCAL SHEAR AND SHEAR HISTORICAL EFFECTS ON THROMBOSIS: APPLICATIONS TO HEART-ASSIST DEVICES AND HYPERINFLAMMATORY STATES (opens in a new tab)

  11. Haemodynamic Assessment of Coronary Flow with CFD and Phase-Contrast MRI

    … of restenosis and in-stent thrombosis. Coronary flow patterns, determined by vessel geometry and stent design and deployment, are thought to be related to adverse clinical outcomes. This thesis represents a comprehensive assessment of the relationships between flow and major coronary artery …

    auckland-ms Repository record for Haemodynamic Assessment of Coronary Flow with CFD and Phase-Contrast MRI (opens in a new tab)

  12. Flow Induced Vibration in Corrugated Metal Flexhoses

    This study on flow-induced vibration provides valuable insights into the fundamental dynamics of fluid-structure interactions. The findings contribute to the development of predictive models and design guidelines for engineering systems susceptible to flow-induced vibration. By improving our …

    ucf Repository record for Flow Induced Vibration in Corrugated Metal Flexhoses (opens in a new tab)

  13. Expanding the Performance Envelope of the Total Artificial Heart: Physiological Characterization, Development of a Heart Failure Model, And Evaluation Tool for Mechanical Circulatory Support Devices

    … pressure were noted to be elevated, aortic flow was reduced, sensitivity to afterload was increased, and Starling-like behavior was blunted, consistent with human heart failure. The system was then configured to allow ready addition of ventricular assist devices, which upon placement in the …

    arizona-thes Repository record for Expanding the Performance Envelope of the Total Artificial Heart: Physiological Characterization, Development of a Heart Failure Model, And Evaluation Tool for Mechanical Circulatory Support Devices (opens in a new tab)

  14. Computational Fluid Dynamics Modelling of Coronary Artery Disease

    … assessment with indices such as fractional flow reserve (FFR) is now accepted as the invasive gold-standard for diagnosing the significance of CAD and for guiding treatment. Patients undergoing percutaneous coronary intervention (PCI) guided by FFR have better clinical outcomes than those …

    whiterose Download PDF for Computational Fluid Dynamics Modelling of Coronary Artery Disease (opens in a new tab)

  15. Transvalvular pressure drop estimation for aortic stenosis

    … valve leaflets results in obstruction of blood flow from the left ventricle into the aorta. No pharmacological therapies are successful at preventing aortic stenosis or arresting progression and therefore valve replacement is clinically indicated where symptoms arise due to severe obstruction, …

    kings Repository record for Transvalvular pressure drop estimation for aortic stenosis (opens in a new tab) Download PDF for Transvalvular pressure drop estimation for aortic stenosis (opens in a new tab)

  16. Pressure Wave Velocity Using High-Frame-Rate Ultrasound Imaging for Urodynamic Study

    … through visualization of high temporal urinary flow dynamics within the male urinary tract during voiding. Such work has shown that characteristic flow patterns for pathological states found within the diseased male urinary tract, such as urethral obstruction, can be used for non-invasive …

    waterloo Repository record for Pressure Wave Velocity Using High-Frame-Rate Ultrasound Imaging for Urodynamic Study (opens in a new tab)

  17. Dielectrophoresis at wireless bipolar electrode arrays: Applications to the marker-free selection and detection of circulating tumor cells

    … isolate CTCs in micropockets, while blood cells flow through the channels. The capture methodology used here eliminates massively screening of all cell populations one-by-one, the case in droplet separation, thus greatly increasing sorting efficiency. Further, high-fidelity single-cell capture …

    iastate Repository record for Dielectrophoresis at wireless bipolar electrode arrays: Applications to the marker-free selection and detection of circulating tumor cells (opens in a new tab)

  18. 3D Printing of Functional Anthropomorphic Phantoms Using Soft Materials for Applications in Cardiology

    … phantoms that can withstand physiological flow conditions or have functional components, such as valves. However, silicone is a resilient soft tissue-mimicking material used commonly to make anthropomorphic phantoms. In Chapter 6, silicone aorta and aortic valve phantoms were constructed …

    kings Repository record for 3D Printing of Functional Anthropomorphic Phantoms Using Soft Materials for Applications in Cardiology (opens in a new tab) Download PDF for 3D Printing of Functional Anthropomorphic Phantoms Using Soft Materials for Applications in Cardiology (opens in a new tab)