Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 63 for “"Flow detection."”.

  1. Random signal ultrasonic blood flow detection

    Thesis (M.S.)--Michigan State University of Agriculture and Applied Science. Dept. of Electrical Engineering and Systems Science, 1973

    msu Repository record for Random signal ultrasonic blood flow detection (opens in a new tab)

  2. The Hanna Neumann conjecture: A flow detection approach

    … on the pullback conjecture. In this light, the Flow Conjecture is stated, and its relationship as an apparently stronger conjecture than the Hanna Neumann Conjecture becomes evident. We then prove the Flow Conjecture for certain special cases by detecting a special kind of ""short"" flow. …

    uiuc Repository record for The Hanna Neumann conjecture: A flow detection approach (opens in a new tab)

  3. Ultrasonic blood flow detection: Doppler techniques for obstetrics

    … Doppler techniques have been developed for the detection of uterine blood flow. The work was undertaken to provide a noninvasive method for the study of foetal haemodynamics.

    edinburgh Repository record for Ultrasonic blood flow detection: Doppler techniques for obstetrics (opens in a new tab)

  4. Particle-Free High Spatial Resolution Velocimetry for Slip Flow Detection

    … Understanding and quantifying the slip flow phenomenon in these microscale and nanoscale channels is of paramount importance for precise control and optimization of fluidic processes. Our study presents a novel approach to directly measure the velocities in a microchannel using Laser …

    south-carolina Repository record for Particle-Free High Spatial Resolution Velocimetry for Slip Flow Detection (opens in a new tab)

  5. Active Learning with semi-supervised Gaussian Mixture Model on Network Flow Detection

    One of the biggest challenges in network flow detection is that the data distribution is extremely unbalanced, which leads to the inability of traditional unsupervised learning to find data features effectively, while semi-supervised/supervised learning methods require a large number of labeled …

    iastate Repository record for Active Learning with semi-supervised Gaussian Mixture Model on Network Flow Detection (opens in a new tab)

  6. Efficient large flow detection over arbitrary windows: an exact algorithm outside an ambiguity region

    Being able to exactly detect large network flows under an arbitrary time win- dow model is expected in many current and future applications like Denial- of-Service (DoS) flow detection, bandwidth guarantee, etc. However, to the best of our knowledge, there is no existing work that can achieve exact …

    uiuc Repository record for Efficient large flow detection over arbitrary windows: an exact algorithm outside an ambiguity region (opens in a new tab)

  7. Real-time Traffic Flow Detection and Prediction Algorithm: Data-Driven Analyses on Spatio-Temporal Traffic Dynamics

    <p>Traffic flows over time and space. This spatio-temporal dependency of traffic flow should be considered and used to enhance the performance of real-time traffic detection and prediction capabilities. This characteristic has been widely studied and various applications have been developed and …

    utk-theses Repository record for Real-time Traffic Flow Detection and Prediction Algorithm: Data-Driven Analyses on Spatio-Temporal Traffic Dynamics (opens in a new tab)

  8. Site reliability against anomalous behaviors

    … mainly focuses on detecting “large” Internet flows consuming more resources than those allocated to them. Being able to identify large flows accurately can greatly benefit Quality of Service (QoS) schemes and Distributed Denial of Service (DDoS) defenses. Although large-flow detection has been …

    uiuc Repository record for Site reliability against anomalous behaviors (opens in a new tab)

  9. Robust Eigen-Filter Design for Ultrasound Flow Imaging Using a Multivariate Clustering

    Blood flow visualization is a challenging task in the presence of tissue motion. Unsuppressed tissue clutter produces flashing artefacts in ultrasound flow imaging which hampers blood flow detection by dominating part of the blood flow signal in certain challenging clinical imaging applications, …

    waterloo Repository record for Robust Eigen-Filter Design for Ultrasound Flow Imaging Using a Multivariate Clustering (opens in a new tab)

  10. Coherent flow power Doppler imaging

    <p>Ultrasonic flow detection is a widely used technique to detect vessel, measure blood flow velocities, and monitor perfusion. Conventional techniques include color Doppler imaging and power Doppler (PD) imaging. These methods depend on either the measurement of phase change or the detection of …

    duke Repository record for Coherent flow power Doppler imaging (opens in a new tab)

  11. Biologically-Inspired Low-Light Vision Systems for Micro-Air Vehicle Applications

    … success while relying heavily on optic flow estimation. Such capabilities are nowhere near being met with current technology, in large part due to limitations of low-light vision systems. This dissertation presents a body of work that enhances the capabilities of visual sensing in …

    maryland Repository record for Biologically-Inspired Low-Light Vision Systems for Micro-Air Vehicle Applications (opens in a new tab)

  12. Η ΧΡΗΣΙΣ ΑΙΜΟΔΥΝΑΜΙΚΩΝ ΜΕΘΟΔΩΝ (DOPPLER) ΠΡΟΣ ΠΡΟΣΔΙΟΡΙΣΜΟ ΤΟΥ ΕΠΙΠΕΔΟΥ ΑΚΡΩΤΗΡΙΑΣΜΟΥ ΕΠΙ ΠΕΡΙΦΕΡΙΚΩΝ ΑΡΤΗΡΙΟΠΑΘΕΙΩΝ

    … LOWER EXTREMITIES WERE STUDIED. THE ULTRASOUND FLOW DETECTION TECHNIQUE AND THE PRESSURE INDEX OF THE ANKLE WERE USED IN ORDER TO DETERMINE THE LEVEL OF AMPUTATION WHERE THE LESIONS WERE IRREVERSIBLE. WHERE AMPUTATION WAS UNAVOIDABLE THE OBJECTIVE WAS TO PERFORM, IF POSSIBLE BELOW-KNEE …

    greece Repository record for Η ΧΡΗΣΙΣ ΑΙΜΟΔΥΝΑΜΙΚΩΝ ΜΕΘΟΔΩΝ (DOPPLER) ΠΡΟΣ ΠΡΟΣΔΙΟΡΙΣΜΟ ΤΟΥ ΕΠΙΠΕΔΟΥ ΑΚΡΩΤΗΡΙΑΣΜΟΥ ΕΠΙ ΠΕΡΙΦΕΡΙΚΩΝ ΑΡΤΗΡΙΟΠΑΘΕΙΩΝ (opens in a new tab)

  13. Response of passive surface hairs in steady and unsteady Falkner-Skan boundary layers.

    … inspired artificial hair sensors for flow detection are being considered to provide small unmanned aerial vehicles greater platform stability through gust mitigation. Analytical models of hair sensor response to flow conditions have been previously developed, but fundamental …

    baylor Repository record for Response of passive surface hairs in steady and unsteady Falkner-Skan boundary layers. (opens in a new tab)

  14. HIGH THROUGHPUT ANALYSIS OF SINGLE CELLS IN RESPONSE TO MECHANICAL CUES USING DROPLET-BASED MICROFLUIDICS

    … droplet-based microfluidics with a continuous flow detection system was developed to tackle the current challenges. The novelty of this work lies in the utilisation of gelatine microspheres as cell carriers to provide adherent cells with both cell-matrix interaction and manoeuvrability. With …

    nus Repository record for HIGH THROUGHPUT ANALYSIS OF SINGLE CELLS IN RESPONSE TO MECHANICAL CUES USING DROPLET-BASED MICROFLUIDICS (opens in a new tab) Download file for HIGH THROUGHPUT ANALYSIS OF SINGLE CELLS IN RESPONSE TO MECHANICAL CUES USING DROPLET-BASED MICROFLUIDICS (opens in a new tab)

  15. The Noninvasive Measurement of Limb Blood Flow by Means of Nuclear Magnetic Resonance

    Primary flow detection devices usually measure parameters related to velocity or mass flow rate. A Nuclear Magnetic Resonance (NMR) flowmeter has been developed to detect limb blood flow noninvasively. The NMR detector generates signals related to the volume and nuclear magnetization level of the …

    marquette Repository record for The Noninvasive Measurement of Limb Blood Flow by Means of Nuclear Magnetic Resonance (opens in a new tab)

  16. Reducing Instrumentation Barriers of Diffuse Correlation Spectroscopy for Low-Cost Deep Tissue Blood Flow Monitoring

    Cerebral blood flow (CBF) is a good indicator of brain health as blood carries necessary nutrients, oxygen, and metabolic byproducts. Quantitative blood flow information can be used in several clinical and therapeutic applications such as stroke detection, measuring autoregulation, evaluating brain …

    usf Repository record for Reducing Instrumentation Barriers of Diffuse Correlation Spectroscopy for Low-Cost Deep Tissue Blood Flow Monitoring (opens in a new tab)

  17. Physicochemical Hydrodynamics and Machine Learning Characterization of Isothermal Nucleic Acid Amplification Nucleation Site Analysis

    … combining RPA-based amplification with lateral flow detection, offering PCR-level sensitivity with LFA-like ease. It meets WHO SARS-CoV-2 detection standards, demonstrates high specificity, variant resilience, and uses a simple lysis method suitable for minimal devices. For HIV viral load …

    washington Repository record for Physicochemical Hydrodynamics and Machine Learning Characterization of Isothermal Nucleic Acid Amplification Nucleation Site Analysis (opens in a new tab)

  18. Integrating graphene Hall sensors with co-designed silicon circuits for high-throughput magnetic biosensing

    … also explores the applications of GHSs for in-flow detection of magnetically labeled particles such as cells, which can be used to diagnose and monitor cancer and infectious diseases using unprocessed blood samples.

    penn Repository record for Integrating graphene Hall sensors with co-designed silicon circuits for high-throughput magnetic biosensing (opens in a new tab) Embargoed until 2027-08-28

Page 1 of 4