Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 24 for “"Flow diverters"”

  1. In-silico clinical trials for assessment of intracranial flow diverters

    … of cost-effective and fully-automatic workflows to enable a large number of simulations at a reasonable computational cost and time. Flow-diverting stents have been proven safe and effective in the treatment of large wide-necked intracranial aneurysms. The presented thesis aims to provide …

    whiterose Repository record for In-silico clinical trials for assessment of intracranial flow diverters (opens in a new tab)

  2. Hemodynamic Modelling and Simulation of Flow Diverters for Intracranial Aneurysm Treatment

    Les anévrismes intracrâniens sont fréquents mais mal compris, malgré les conséquences graves liées à leur rupture. La complexité des processus biochimiques du cerveau et la fragilité de son environnement limitent les études in-vivo. L’étude de la dynamique des fluides numérique (CFD) peut aider à …

    star-france Repository record for Hemodynamic Modelling and Simulation of Flow Diverters for Intracranial Aneurysm Treatment (opens in a new tab)

  3. Magnetic Endothelialization of Flow Diverters to Promote Rapid Healing of Cerebral Aneurysms

    … options, but one of the newest treatments is flow diversion. Flow diverters create a barrier over the neck of the aneurysm that restores flow to the parent vessel and away from the aneurysm. While these devices have high success rates thus far, they are still associated with some clinical …

    marquette Repository record for Magnetic Endothelialization of Flow Diverters to Promote Rapid Healing of Cerebral Aneurysms (opens in a new tab)

  4. Biofonctionnalisation de surface des stents flow-diverters pour le traitement des anévrismes intracrâniens

    Les stents à diversion de flux (flow-diverters, FD) se sont imposés comme une stratégie efficace pour le traitement des anévrismes intracrâniens, en favorisant l’exclusion progressive du sac anévrismal par thrombose et la cicatrisation de l’artère porteuse grâce à la formation d’un néo-tissu sur …

    star-france Repository record for Biofonctionnalisation de surface des stents flow-diverters pour le traitement des anévrismes intracrâniens (opens in a new tab)

  5. Predicting Long-Term Outcome of Intracranial Aneurysms Treated with Flow Diverters Using CFD and Machine Learning

    … challenging aneurysms, a new paradigm called flow diversion using highly dense metallic-stents called flow diverters (FDs) was approved by the FDA in 2011. Since its approval, FDs have become a mainstay of endovascular intervention of not only the traditionally challenging ones, but IAs of all …

    buffalo Repository record for Predicting Long-Term Outcome of Intracranial Aneurysms Treated with Flow Diverters Using CFD and Machine Learning (opens in a new tab)

  6. Conception et validation d'un revêtement mimétique de l'endothélium pour une intégration optimale des dispositifs endovasculaires

    … endovasculaires (DE, tels que les stents et flow-diverters) ont grandement enrichi l'arsenal thérapeutique pour les pathologies artérielles. Toutefois, une réaction pathologique de l'hôte, déclenchée par le DE lui-même, limite les résultats à moyen et long terme des traitements …

    star-france Repository record for Conception et validation d'un revêtement mimétique de l'endothélium pour une intégration optimale des dispositifs endovasculaires (opens in a new tab)

  7. Optimisation biologique du traitement endovasculaire des anévrysmes intracrâniens

    … à l’élastase chez le lapin et traités par coils, flow-diverters ou dispositifs intra-sacculaires (WEB). Ces travaux permettent de mieux comprendre les mécanismes biologiques mis en jeu par les différents traitements endovasculaires. L’analyse de ces phénomènes est indispensable pour comprendre les …

    star-france Repository record for Optimisation biologique du traitement endovasculaire des anévrysmes intracrâniens (opens in a new tab)

  8. Flight testing Flow Diverting Devices on an OH-58A+ for applications to an MH-6 Helicopter

    <p>This study investigates the use of Flow Diverting Devices to reduce passenger fatigue and parasite drag (specifically equivalent flat plate drag) for the 160*'* Special Operations Aviation Regiment MH-6 Helicopters. Due to cost, scheduling, and airworthiness release (AWR's) issues this …

    ut-knoxville Repository record for Flight testing Flow Diverting Devices on an OH-58A+ for applications to an MH-6 Helicopter (opens in a new tab)

  9. Endovascular Treatment of Intracranial Aneurysms in Small Peripheral Vessel Segments—Efficacy and Intermediate Follow- Up Results of Flow Diversion with the Silk Vista Baby Low- Profile Flow Diverter

    … flussrichtenden Implantats, des Silk Vista Baby Flow Diverters zur Versorgung vorrangig distal gelegener, zerebraler Aneurysmen im mittelfristigen Verlauf. Bisherige Studien konnten zu diesem Zeitpunkt infolge der erst kurz zurückliegenden Markteinführung lediglich die periinterventionelle …

    qucosa-diss Repository record for Endovascular Treatment of Intracranial Aneurysms in Small Peripheral Vessel Segments—Efficacy and Intermediate Follow- Up Results of Flow Diversion with the Silk Vista Baby Low- Profile Flow Diverter (opens in a new tab)

  10. A method for the development of an effective flow diverting device for the treatment of cerebral aneurysms

    … as a more effective treatment than coiling. A flow diverter is placed inside the parent vessel, spanning the aneurysm neck. The diverter's braided structure keeps most of the blood from entering the aneurysm. The risk of rupture is eliminated when stagnant pools of blood thrombose inside the …

    umn Repository record for A method for the development of an effective flow diverting device for the treatment of cerebral aneurysms (opens in a new tab)

  11. Customization of Aneurysm Scaffold Geometries for In Vitro Tissue-Engineered Blood Vessel Mimics to Use As Models for Neurovascular Device Testing

    … devices, such as embolization coils and flow diverters, are methods of treatment utilized to prevent aneurysm rupture. The rapidly growing market for neurovascular devices necessitates the development of accurate aneurysm models for preclinical testing. In vivo models, such as the rabbit …

    calpoly Repository record for Customization of Aneurysm Scaffold Geometries for In Vitro Tissue-Engineered Blood Vessel Mimics to Use As Models for Neurovascular Device Testing (opens in a new tab)

  12. La diversion de flux dans le traitement des anévrismes cérébraux : des études pré-cliniques aux études cliniques

    … une revue systématique sur les stents dits «Flow Diverters» (FD) et les modèles animaux. Puis nous avons mené quatre expérimentations animales évaluant l’efficacité des FDs dans différents modèles d’anévrismes canins adaptés à l’hypothèse de travail par l’application d’une méthodologie …

    star-france Repository record for La diversion de flux dans le traitement des anévrismes cérébraux : des études pré-cliniques aux études cliniques (opens in a new tab)

  13. Υποβοηθούμενος από stent εμβολισμός εγκεφαλικών ανευρυσμάτων / Stent assisted coil embolization of intracranial aneurysms

    … μεθόδους (απλός εμβολισμός με σπειράματα, BAC, flow diverters, χειρουργικός αποκλεισμός, αποκλεισμός μητρικής αρτηρίας) αναδεικνύει πλεονεκτήματα και μειονεκτήματα που αφορούν κυρίως τη μακροπρόθεσμη έκβαση και την ασφάλεια της μεθόδου. Νεότερες ενδοπροθέσεις φαίνεται να αυξάνουν τις ενδείξεις …

    athens Repository record for Υποβοηθούμενος από stent εμβολισμός εγκεφαλικών ανευρυσμάτων / Stent assisted coil embolization of intracranial aneurysms (opens in a new tab)

  14. Particle Image Velocimetry in Cerebral Aneurysm Models to Evaluate Fluid Dynamic Performance of Flow Diverting Stents Across Parent Vessel Sizes

    … current standard of treatment for WNAs is the flow diverter which minimizes aneurysmal inflow and provides an endovascular scaffold for the parent vessel, ultimately inducing aneurysm occlusion. As the use of flow diverters has expanded to include a wider range of clinical scenarios, aneurysm …

    gatech Repository record for Particle Image Velocimetry in Cerebral Aneurysm Models to Evaluate Fluid Dynamic Performance of Flow Diverting Stents Across Parent Vessel Sizes (opens in a new tab)

  15. Impact de l'anévrisme intracrânien sur l'hémodynamique de l'artère porteuse : de l’observation in vitro à l’exploration in vivo

    … corrélé au volume de l'anévrisme. Les stents flow diverters permettaient une « reconstruction hémodynamique » mesurable du vaisseau porteur en restaurant un flux normo-modulé et des index de pulsatilité et de résistance dans les limites de la normale. Une méthode originale pour la segmentation …

    star-france Repository record for Impact de l'anévrisme intracrânien sur l'hémodynamique de l'artère porteuse : de l’observation in vitro à l’exploration in vivo (opens in a new tab)

  16. Flow Physics of Fluidically Controlled Attachment in Separation Cells

    Internal flows subjected to adverse pressure gradients are susceptible to three-dimensional separation on flow boundaries that can result in flow instabilities and significant losses. Active, surface-integrated flow control offers an attractive approach for mitigating these adverse effects by …

    gatech Repository record for Flow Physics of Fluidically Controlled Attachment in Separation Cells (opens in a new tab)

  17. Computational model of thrombosis in cerebral aneurysms for predicting clotting outcomes in flow diverter treated patient-derived geometries validated with novel PIV-based ln vitro clotting flow experiment

    … measuring the ongoing interaction between flow and clot-growth; a key factor in predicting aneurysm-occlusion after surgical placement of a stent. To this end, a pulsatile-flow direct thrombosis-model has been developed towards use in a clinical environment to predict thrombosis outcomes in …

    cape-town Repository record for Computational model of thrombosis in cerebral aneurysms for predicting clotting outcomes in flow diverter treated patient-derived geometries validated with novel PIV-based ln vitro clotting flow experiment (opens in a new tab)

  18. Fluid-structure interaction simulations for medical applications

    … and the surrounding fluid. When a fluid flow hits the structure, stresses and strains are exerted on the solid body. Large forces can lead to large deformations, especially if the structure is made of a soft material. Then, the fluid domain around the solid is subjected to significant …

    ttu Repository record for Fluid-structure interaction simulations for medical applications (opens in a new tab)

  19. Aneurisma do segmento oftálmico da artéria carótida interna: características clínicas, angiográficas e resultados do tratamento endovascular

    … expansíveis com balão, auto-expansíveis ou flow-diverters. Conclusões: Os aneurismas foram excluídos totalmente em 93% dos casos. No seguimento, 18 pacientes foram reoperados (11%), a taxa de complicações foi de 12,8%. O tempo médio de acompanhamento após a intervenção foi de três anos por …

    brazil-ufpe Repository record for Aneurisma do segmento oftálmico da artéria carótida interna: características clínicas, angiográficas e resultados do tratamento endovascular (opens in a new tab)

Page 1 of 2