Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 53 for “"Flow injection analysis (FIA)"”.
-
Flow injection analysis (FIA) determination of lead by hydride generation in banded coral skeletons /
A flow injection hydride generation direct current plasma atomic emission spectrometric (FI-HG-DCP-AES) method was developed for the determination of lead at ng.ml-l level. Potassium ferricyanide (K3Fe(CN)6) was used along with sodium tetrahydroborate(III) (NaBH4) to produce plumbane (PbH4) in an …
-
ΕΦΑΡΜΟΓΕΣ ΤΗΣ FLOW INJECTION ANALYSIS (FIA) ΚΑΙ ΤΩΝ ΑΚΙΝΗΤΟΠΟΙΗΜΕΝΩΝ ΕΝΖΥΜΩΝ ΣΤΗΝ ΑΝΑΛΥΣΗ ΔΕΙΓΜΑΤΩΝ ΤΡΟΦΙΜΩΝ ΚΑΙ ΒΙΟΛΟΓΙΚΩΝ ΥΓΡΩΝ
… ΤΩΝ ΤΡΟΦΙΜΩΝ ΚΑΙ ΒΙΟΛΟΓΙΚΩΝ ΥΓΡΩΝ ΜΕ ΤΗΝ ΤΕΧΝΙΚΗ FIA. Η ΜΕΘΟΔΟΛΟΓΙΑ ΣΤΗΡΙΧΘΗΚΕ ΣΤΗΝ ΤΟΠΟΘΕΤΗΣΗ ΑΝΤΙΔΡΑΣΤΗΡΩΝ ΑΠΛΗΣ ΣΕΙΡΙΑΚΗΣ ΔΙΑΤΑΞΗΣ ΜΕ ΑΚΙΝΗΤΟΠΟΙΗΜΕΝΑ ΕΝΖΥΜΑ ΣΕ ΣΥΣΚΕΥΗ FIA, ΠΟΥ ΣΥΝΑΡΜΟΛΟΓΗΘΗΚΕ ΣΤΟ ΕΡΓΑΣΤΗΡΙΟ ΚΑΙ ΣΤΗ ΦΑΣΜΑΤΟΦΩΤΟΜΕΤΡΙΚΗ ΑΝΑΛΥΣΗ ΔΙΑΦΟΡΩΝ ΣΥΣΤΑΤΙΚΩΝ. ΑΚΙΝΗΤΟΠΟΙΗΘΗΚΑΝ ΚΑΙ …
-
Investigations in flow injection analysis (FIA): conventional FIA determination of chloride in water; sequential injection (SI)-FIA determination of mercury in water
Flow injection analysis (FIA) was applied to the determination of both chloride ion and mercury in water. Conventional FIA was employed for the chloride study. Investigations of the Fe3 +/Hg(SCN)2/CI-,450 nm spectrophotometric system for chloride determination led to the discovery of an absorbance …
-
Applications of Acousto-Optic Tunable Filters in Liquid Chromatography and Flow Injection Analysis
… filter (AOTF) in liquid chromatography (LC) and flow injection analysis (FIA) were instrumentally exploited. The advantages of AOTFs have been demonstrated to be useful in analytical instrumentation.
-
Applications of Bipolar Pulse Conductance to Flowing Streams (Enzymes, Hplc, Immobilized, Fia)
The use of flowing streams, particularly flow injection analysis (FIA), to facilitate analytical measurements has increased significantly in the past several years. Conductance has generally not been used as a detector for flowing streams. Two reasons for this are conductance's lack of selectivity …
-
The Effects of Ozone Deposition and Dissolved Organic Matter on Manganese Speciation in the Surface Ocean
… in seawater. This study focused on developing a flow injection analysis (FIA) chemiluminescence system to measure Mn(II) in order to investigate the effect of O_(3) deposition to the sea surface on Mn speciation. Modifications to earlier FIA systems had to be made in order to accommodate the …
-
Selected flow injection analytical methods and their application in the study of the sulphur nutrition of barley: a thesis
A comprehensive review of the literature on flow injection analysis (FIA) revealed considerable scope for the development of automated and microprocessor-controlled flow systems for the determination of sulphate-S (S04-S), total-S, copper (Cu), zinc (Zn), manganese (Mn), and iron (Fe) in plant …
-
Multicomponent flow injection analysis and quantitative infrared emission spectroscopy: chemometric applications
… developed which have been found useful in the analysis of chemical data. The developments in this volume include the use of chemometric methods in two areas which have generally been overlooked in the past. The first is the use of flow injection analysis (FIA) methods for mixtures using …
-
Determination of hydrogen peroxide using immobilized chemiluminescence reagents and flow injection analysis
… the CL determination of hydrogen peroxide using flow injection analysis (FIA) was investigated. Nylon was initially chosen as the immobilization support because of its chemical inertness. Luminol was covalently immobilized on the inside of nylon tubing and used for FIA determination of peroxide …
-
Evaluation of a direct injection nebulizer interface for flow injection analysis and high performance liquid chromatography with inductively coupled plasma-atomic emission spectroscopic detection
<p>A direct injection nebulizer (DIN) was designed, developed, and evaluated to determine its potential utilization as an effective inter- face for flow injection analysis (FIA) and high performance liquid chromatography (HPLC) coupled with inductively coupled plasma-atomic emission spectroscopic …
-
Characteristics and applications of the enhanced HRP-catalyzed oxidation of luminol
… luminol has received much attention in chemical analysis. An analytically useful CL system which has also received much attention in recent years is the enhanced horseradish peroxidase (HRP)-catalyzed luminol reaction. Generally, the enhancers are halogenated phenols or aromatic amines. …
-
Ανάπτυξη και Επικύρωση Μεθόδων για τον Προσδιορισμό της Αντιοξειδωτικής Ικανότητας Λευκών Οίνων με Αυτοματοποιημένες Διατάξεις Ροής
… στην τεχνική των διαδοχικών εγχύσεων (Sequential Injection Analysis, SIA), ενώ η δεύτερη μέθοδος βασίστηκε στην τεχνική της έγχυσης δείγματος σε ροή (Flow Injection Analysis, FIA) χρησιμοποιώντας το γαλλικό οξύ ως πρότυπο αντιοξειδωτικό. Αρχικά, έγινε μελέτη της στατιστικής σημαντικότητας των …
-
Fourier transform infrared spectrometric detection of chromatographic effluents: instrumental and methodological improvements using a flow cell interface
… untested forms of chromatography using a flow cell interface. These forms of chromatography include High Performance Liquid Chromatography (HPLC), both normal-phase and reversed-phase, and packed-column Supercritical Fluid Chromatography (SFC). Normal phase HPLC-FTIR was demonstrated on …
-
Development of a microfluidic based analytical system for copper monitoring in environmental water samples
… Work initially focussed on the development of a flow injection analysis (FIA) system with micellar enhanced chemiluminescence (CL) detection. Sufficient selectivity was achieved by removing interfering metal ions using an on-line itaconic acid modified microcolumn, allowing copper (II) to be …
-
The biogeochemistry of dimethylsulphoniopropionate (dmsp) in estuarine sediments
… in estuarine sediments. A reaction-based flow injection analysis (FIA) system that was developed enabled the detection and quantification of trace levels of dissolved sulphide, DMSP and DMS precursors, exhibiting detection limits of ca 10<sup>-6</sup> M. An acid reaction step permits the …
-
Flow Injection Analysis of industrial water samples
An automated version of Flow Injection Analysis (FIA) instrumentation has been designed and evaluated for the quantitative determination of chemical oxygen demand (COD) for industrial samples. The distinct advantages over conventional COD assays are the significantly reduced analysis time (FIA …
-
Analytical applications of chemically modified antibodies.
… the ELISA and to make the assay adaptable to a flow injection analysis (FIA) configuration. The goal being the total automation of the ELISA procedure which is long, tedious and has high standard deviation. The antibody purification and cleavage methods were studied with special emphasis on …
-
Analytical applications of sensor arrays and virtual instrumentation
… system using Ion-Selective Electrodes (ISEs) in Flow-Injection Analysis (FIA) is described. Because of the low selectivity of the nonactin ammonium selective electrode towards some common ions, different selectivity enhancement techniques have been examined. A Sensor Array Detector (SAD) which …
-
Phosphorus Speciation In Soil Leachate Using Field-flow Fractionation And Flow Injection Analysis
… and relatively new separation technique field-flow fractionation (FFF) can be used to fractionate complex colloidal samples. By combining FFF and flow injection analysis (FIA) more detailed physico-chemical information on phosphorus species in soil leachates and agricultural runoff waters can …
-
Studies of immobilized antibody supports and their use in chromatographic immunoassays
… immunoassay system for the simultaneous analysis of albumin and creatinine in urine. Albumin was determined by injecting samples onto a column containing immobilized anti-albumin antibodies. A flow injection analysis (FIA) system following this column was used to quantitate creatinine …
Page 1 of 3