Showing 1 to 20 of 144 for “"Flow meters"”.

  1. The use of pipe elbows as flow meters.

    … the previous studies of pipe elbows for use as flow meters lave led to the conclusion that it is necessary to calibrate each elbow desired to be used as an accurate flow meter in its service location. Considering the various advantages an elbow meter possessed over the other types, this …

    ut-knoxville Repository record for The use of pipe elbows as flow meters. (opens in a new tab)

  2. Comparison of Selected Differential Producing, Ultrasonic, and Magnetic Flow Meters

    Flow meters are used to measure flow accurately. There are many different flow meters and it is necessary to know which will function best for specific situations. A wide variety of flow meters were selected for the study to assist in showing that each flow meter has its tradeoffs. The selected …

    utahstate Repository record for Comparison of Selected Differential Producing, Ultrasonic, and Magnetic Flow Meters (opens in a new tab)

  3. Miniature, High Efficiency Transducers For Use IN Ultrasonic Flow Meters

    … high efficiency transducer for use in ultrasonic flow meters. The proposed transducer consists of a thin plate of a suitable piezoelectric material on which an inter-digital transducer is fabricated for the generation and detection of plate acoustic waves. When immersed in a fluid medium, this …

    marquette Repository record for Miniature, High Efficiency Transducers For Use IN Ultrasonic Flow Meters (opens in a new tab)

  4. Can mass flow meters solve the problem with discrepancies in bunker deliveries?

    … made its way in to the market, the Coriolis Mass Flow Meter. This flow meter measures the mass directly, instead of volume and is more difficult to tamper with. The method used for this study was a qualitative method with semi-structured interviews. The selected respondents are actors within the …

    chalmers Repository record for Can mass flow meters solve the problem with discrepancies in bunker deliveries? (opens in a new tab)

  5. Computational Investigation of the Discharge Coefficient of Bellmouth Flow Meters in Engine Test Facilities

    … of the discharge coefficient of bellmouth flow meters installed in engine test facilities is presented. The discharge coefficient is a critical parameter for accurately calculating flow rate in any flow meter which operates by means of creating a pressure differential. Engine airflow is a …

    utk-theses Repository record for Computational Investigation of the Discharge Coefficient of Bellmouth Flow Meters in Engine Test Facilities (opens in a new tab)

  6. Parental perception concerning the use of peak flow meters in the child with asthma

    … parental perceptions concerning the use of peak flow meters (PFM) in their children. The sample consisted of 20 parents who were accessed through outpatient asthma allergy clinics. The questionnaire and semi-structured interview were utilized as tools and analyzed using inferential statistics and …

    unlv Repository record for Parental perception concerning the use of peak flow meters in the child with asthma (opens in a new tab) Download PDF for Parental perception concerning the use of peak flow meters in the child with asthma (opens in a new tab)

  7. Application of Computational Fluid Dynamics to Determine Gas Expansion Factors of Differential Pressure Flow Meters

    … predict gas expansion in differential pressure flow meters. Differential pressure flow meters are used to measure the flow rate of pressurized liquids and gases through pipes. Computer simulations of liquid and gas flows were conducted for three distinct differential pressure flow meter …

    utahstate Repository record for Application of Computational Fluid Dynamics to Determine Gas Expansion Factors of Differential Pressure Flow Meters (opens in a new tab)

  8. The Effects of Meter Orientation Downstream of a Short Radius Elbow on Electromagnetic Flow Meters

    Electromagnetic flowmeters (known as magnetic flow meters) are a widely used type of flowmeter. The accuracy of magnetic flow meters are a function of several factors, not the least of which is the flow condition inside the pipe. It has been shown that disturbances in the velocity profile affects …

    utahstate Repository record for The Effects of Meter Orientation Downstream of a Short Radius Elbow on Electromagnetic Flow Meters (opens in a new tab)

  9. Evaluation of a Close Coupled Slotted Orifice, Electrical Impedance, and Swirl Flow Meters for Multiphase Flow

    … of a coupled slotted orifice and swirl flow meters, and a coupled slotted orifice and an impedance probe flow meter for multiphase flow is evaluated to develop a new multiphase flow meter. The slotted orifice also provides well homogenized flow for several pipe diameters downstream of …

    tamu Repository record for Evaluation of a Close Coupled Slotted Orifice, Electrical Impedance, and Swirl Flow Meters for Multiphase Flow (opens in a new tab)

  10. Discharge Coefficient Performance of Venturi, Standard Concentric Orifice Plate, V-Cone, and Wedge Flow Meters at Small Reynolds Numbers

    … was investigated through differential pressure flow meters. The focus of the study was directed toward very small Reynolds numbers commonly associated with pipeline transportation of viscous fluids. There is currently a relatively small amount of research that has been performed in this area for …

    utahstate Repository record for Discharge Coefficient Performance of Venturi, Standard Concentric Orifice Plate, V-Cone, and Wedge Flow Meters at Small Reynolds Numbers (opens in a new tab)

  11. CFD-Based Sensitivity Study of Flow and Design Parameters in Multiphase Flow Meters. Analyzing the Impact of Variable Conditions on Homogeneity and Measurement Accuracy

    In subsea oil- and gas applications, multiphase flow meters (MPFM) are used to measure volumetric flow rates of oil, gas and water produced from a well, without first separating the phases. When well productions decline the flow may become unstable, requiring additional controls. In these cases …

    chalmers Repository record for CFD-Based Sensitivity Study of Flow and Design Parameters in Multiphase Flow Meters. Analyzing the Impact of Variable Conditions on Homogeneity and Measurement Accuracy (opens in a new tab)

  12. Assessing the Effects of Local Turbulence and Velocity Profiles on Electromagnetic Flow Meter Accuracy

    … velocity profiles on electromagnetic (magnetic) flow meters. According to the American Water Works Association, “No tool available to water utilities has played a greater part in the conservation of water than the water meter (AWWA 2002).” Consequently, it is imperative to understand what …

    utahstate Repository record for Assessing the Effects of Local Turbulence and Velocity Profiles on Electromagnetic Flow Meter Accuracy (opens in a new tab)

  13. CFD Analysis of Viscosity Effects on Turbine Flow Meter Performance and Calibration

    <p>In this research turbine flow meters were studied, using computational fluid dynamics (CFD) modeling to the study effects of viscosity on the flow meters, across a wide range of operation, to improve our understanding and their performance. A three-dimensional computational model was created for …

    ut-knoxville Repository record for CFD Analysis of Viscosity Effects on Turbine Flow Meter Performance and Calibration (opens in a new tab)

  14. A low level motion controller for path tracking control of a tracked mobile robot

    … system to be used in conjunction with hydraulic flow meters to detect track slippage, and the implementation of a basic track slippage controller. The low level system, consisting of the cross-coupling motion controller and the track controllers, was modeled and simulated. The stability of the …

    ubc Repository record for A low level motion controller for path tracking control of a tracked mobile robot (opens in a new tab) Download PDF for A low level motion controller for path tracking control of a tracked mobile robot (opens in a new tab)

  15. Partially Closed Valve Effects on Electromagnetic Flow Meter Accuracy

    … even result in a depleted resource. Generally, flow meters need a flow profile to be fully developed so to optimizemeasurement accuracy. In order to produce accurate measurements, most flow meters require a straight section of pipe immediately upstream of the meter. The straight pipe helps to …

    utahstate Repository record for Partially Closed Valve Effects on Electromagnetic Flow Meter Accuracy (opens in a new tab)

  16. Application of Computational Fluid Dynamics in Flow Measurement and Meter Design

    Flow measurement has been an important part of society for hundreds of years. For this reason there are many methods to measure flow rates both in open channel scenarios like irrigation canals and also in closed conduits like pipelines that supply water for human use. This research focused on …

    utahstate Repository record for Application of Computational Fluid Dynamics in Flow Measurement and Meter Design (opens in a new tab)

  17. The Effects of Upstream Straight Pipe Length on Magnetic Flow Meter Accuracy

    … water systems, being able to accurately measure flow is absolutely essential. For many meter designs, including electromagnetic induction meters (also known as magnetic flow meters), the greatest accuracy is achieved when the device is calibrated correctly. Optimal meter accuracy often depends on …

    utahstate Repository record for The Effects of Upstream Straight Pipe Length on Magnetic Flow Meter Accuracy (opens in a new tab)