Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 5 of 5 for “"Fluence modulation"”.

  1. Development and validation of two novel x-ray filters in computed tomography with focus on fluence modulation for region-of-interest imaging

    … und aufgabenspezifische CT Bildgebung ist die Modulation des Fluenzbereichs (FFM) unter Verwendung eines dynamischen Strahlabschwächers (DBA). DBAs ermöglichen es, die Röntgenfluenz während der Datenaufnahme anzupassen. Existierende DBA-Konzepte zeigen jedoch grundsätzliche Schwachstellen (z.B. …

    lmu-germany Repository record for Development and validation of two novel x-ray filters in computed tomography with focus on fluence modulation for region-of-interest imaging (opens in a new tab)

  2. Monte carlo modelling and dosimetric evaluation of cobalt-60 teletherapy in advanced radiation oncology

    … concerning these in cobalt-60 teletherapy. The influence of the lower energy and penetration of a cobalt-60 beam compared with linear accelerator beams in negligible for intensity-modulated radiotherapy. Recent innovations include the incorporation of magnetic resonance imaging guidance in …

    nwu-za Repository record for Monte carlo modelling and dosimetric evaluation of cobalt-60 teletherapy in advanced radiation oncology (opens in a new tab)

  3. TOWARD A MORE CLARIFIED DETECTIVE QUANTUM EFFICIENCY METHODOLOGY: STUDY OF THE DQE THEORY AND APPLICATIONS

    … constituent parts of DQE, including the photon fluence, Modulation Transfer Function (MTF), and Noise Power Spectrum (NPS) are also discussed in this dissertation.

    oklahoma-thes Repository record for TOWARD A MORE CLARIFIED DETECTIVE QUANTUM EFFICIENCY METHODOLOGY: STUDY OF THE DQE THEORY AND APPLICATIONS (opens in a new tab)

  4. An evaluation of patient-specific IMRT verification failures

    … were resolved. Three distinct indices of fluence modulation (or complexity) were shown to correlate with verification metrics. This indicated that deficiencies in both the leaf motion calculator and the PBC (Eclipse version 8.1.18) had likely contributed to the production of failures. In …

    uvic Repository record for An evaluation of patient-specific IMRT verification failures (opens in a new tab)

  5. Passively Q-Switched and Mode-Locked Pulse Generation in a Ho: YAG Laser

    … the SESAM behaviour, three SESAMs with different modulation depths are used within the laser configuration, yielding three distinct Q-switched pulse regimes. Using an 18% modulation depth SESAM, 70 ns pulses at a repetition rate of 59 kHz and wavelength of 2090.1 nm for average powers of 3.6 W are …

    adelaide Repository record for Passively Q-Switched and Mode-Locked Pulse Generation in a Ho: YAG Laser (opens in a new tab)