Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 13 of 13 for “"Fluorescence angiography"”

  1. Intraoperative, Quantitative, and Non-Contact Blood Volume Flow Measurement via Indocyanine Green Fluorescence Angiography

    In vielen Fällen unterziehen sich Patienten einer Revaskularisationsoperation wenn sie an einer zerebrovaskulären Erkrankung leiden, die eine Hypoperfusion des Gehirns verursacht. Dieser chirurgische Eingriff wird häufig als offene Operation durchgeführt und hat das Ziel, die Gefäßfunktion, …

    karlsruhe-diss Repository record for Intraoperative, Quantitative, and Non-Contact Blood Volume Flow Measurement via Indocyanine Green Fluorescence Angiography (opens in a new tab)

  2. Vergleich der hyperspektralen Bildgebung und der Fluoreszenzangiographie zur Bestimmung des geeigneten Resektionsrandes bei kolorektalen Eingriffen - eine vergleichende Studie.

    … of this issue is limited, but new methods like fluorescence angiography with indocyanine green or non-invasive and contactless hyperspectral imaging have evolved as objective parameters for perfusion evaluation. Methods: In this prospective, non-randomized, open-label and two-arm study, …

    qucosa-diss Repository record for Vergleich der hyperspektralen Bildgebung und der Fluoreszenzangiographie zur Bestimmung des geeigneten Resektionsrandes bei kolorektalen Eingriffen - eine vergleichende Studie. (opens in a new tab)

  3. Αξιολόγηση της χρήσης ICG (Indocyanine Green) και ανάλυση παραμέτρων που επηρεάζουν την έκβαση στη ρομποτική κολεκτομή

    … that enhances intraoperative guidance through fluorescence imaging. The present doctoral thesis investigated the full spectrum of perioperative applications of ICG during robotic colectomy, with particular emphasis on preoperative tumor marking and its comparative evaluation against the …

    greece Repository record for Αξιολόγηση της χρήσης ICG (Indocyanine Green) και ανάλυση παραμέτρων που επηρεάζουν την έκβαση στη ρομποτική κολεκτομή (opens in a new tab)

  4. Uses of near infrared and spectral imaging in colorectal surgery

    … with advancements in spectral imaging, fluorescence imaging, and artificial intelligence presents an opportunity to enhance intraoperative data utilisation in colorectal surgery. Addressing challenges such as identifying lymph node drainage patterns and reducing anastomotic leaks is …

    ucl Repository record for Uses of near infrared and spectral imaging in colorectal surgery (opens in a new tab)

  5. UNDERSTANDING ANATOMICAL PERFUSION AND STRATEGIES TO OPTIMIZE VASCULARITY IN FREE TISSUE TRANSFER FOR AUTOLOGOUS BREAST RECONSTRUCTION USING THE DEEP INFERIOR EPIGASTRIC ARTERY PERFORATOR (DIEP) FLAP

    … three and four-dimensional computed tomographic angiography (CTA) were used to evaluate patterns of the microvascular blood supply of individual perforators and corresponding perfusion patterns in the hemi-abdomen. This was combined with an in-vivo clinical study of women undergoing bilateral …

    cambridge Repository record for UNDERSTANDING ANATOMICAL PERFUSION AND STRATEGIES TO OPTIMIZE VASCULARITY IN FREE TISSUE TRANSFER FOR AUTOLOGOUS BREAST RECONSTRUCTION USING THE DEEP INFERIOR EPIGASTRIC ARTERY PERFORATOR (DIEP) FLAP (opens in a new tab)

  6. Laser speckle contrast imaging as a tool for surgical guidance in neurosurgery

    … standard CBF monitoring technologies, such as fluorescence angiography and microvascular Doppler sonography, demonstrating high agreement. These findings highlight the potential of LSCI as a valuable adjunct for evaluating vessel flow during neurosurgery. Furthermore, the continuous and dynamic …

    texas Repository record for Laser speckle contrast imaging as a tool for surgical guidance in neurosurgery (opens in a new tab)

  7. Experimental porcine models of retinal ischemia

    … multifocal ERG with fundus imaging, fluorescence angiography and conventional angiography. The porcine model of pressure-induced retinal ischaemia resulted in multifocal ERG changes typical of retinal ischaemia although there may be a confounding problem of pressure-induced damage. …

    lund Repository record for Experimental porcine models of retinal ischemia (opens in a new tab)

  8. Assessment of Operative Strategies to Improve Coronary Bypass Graft Patency

    … of a new technique of intraoperative fluorescence angiography using indocyanine green dye to determine graft patency. We developed optimal methods of obtaining images and preliminary investigations revealed the technique was highly reproducible. In a follow-up trial, we demonstrated …

    toronto-retro Repository record for Assessment of Operative Strategies to Improve Coronary Bypass Graft Patency (opens in a new tab)

  9. Perforating blood vessel selection in deep inferior epigastric artery perforator flaps

    … and skin in zone IV using SPY Indocyanine-green-fluorescence-angiography scans on the same perforator combinations as in our animal study, listed above. Results: All data were analysed using non-parametric analyses and revealed that in our animal model, total pedicle flow was significantly …

    glasgow Repository record for Perforating blood vessel selection in deep inferior epigastric artery perforator flaps (opens in a new tab)

  10. Noncontact Multiscale Diffuse Optical Imaging of Deep Tissue Hemodynamics in Animals and Humans

    … and breast reconstruction were imaged by a fluorescence angiography system (SPY-PHI, Novadaq) after the injection of indocyanine green (ICG). Because the ischemic areas have irregular shapes, an innovative contour-based algorithm was used to compare 3D images of blood flow and 2D maps of ICG …

    uky-thes Repository record for Noncontact Multiscale Diffuse Optical Imaging of Deep Tissue Hemodynamics in Animals and Humans (opens in a new tab)

  11. Modulation of inflammatory pathway by inflammatory inhibitor JSH-23 mitigates diabetic retinopathy.

    … were measured before and after treatment. Fluorescence angiography (FA), optical coherence tomography (OCT), and dark-adapted electroretinogram were performed before and after the treatment. Also, intraperitoneal glucose tolerance test (GTT) were performed in the animals before and after …

    louisville Repository record for Modulation of inflammatory pathway by inflammatory inhibitor JSH-23 mitigates diabetic retinopathy. (opens in a new tab)

  12. Évaluation de la perfusion viscérale et anastomotique par réalité augmentée basée sur la fluorescence

    La technique de réalité augmentée basée sur la fluorescence permet de quantifier la dynamique d’un signal fluorescent et de superposer une cartographie de perfusion aux images laparoscopiques en temps réel. Un modèle d’ischémie colique a été choisi afin de différencier différents types d’ischémie …

    star-france Repository record for Évaluation de la perfusion viscérale et anastomotique par réalité augmentée basée sur la fluorescence (opens in a new tab)