Results 1 to 20 of 112 for “"Fluorescent lamps."”
-
A discrete dimming ballast for linear fluorescent lamps
A new discrete dimming ballast for the linear fluorescent lamps is proposed in this paper. The dimming control circuit is combined with a ballast module for multiple lamps to realize three discrete lighting levels control. Compared with conventional step dimming or odoff control methods, the …
-
An improved electronic ballast for the fluorescent lamps
… become an attractive topology for ballasting the fluorescent lamps because it eliminates the use of a bulky boost inductor. But the high voltage stress on the semiconductor devices at light load conditions, the high total harmonic distortion (THO) of the line current, and the poor crest factor ( …
-
Recovery of rare earth oxides from waste fluorescent lamps, The
Phosphor dust was characterized to quantify the various mineralogical phases. QEMSCAN determined that more than 70% of the rare earth minerals are less than 10µm in size and the main gangue material, quartz, was primarily larger than 74µm. Beginning with a europium and yttrium-rich pregnant leach …
-
A Dimmable High Power Factor Electronic Ballast for Compact Fluorescent Lamps
Incandescent lamps are now being gradually replaced by Compact Fluorescent Lamps (CFLs) as CFLs consume less power to produce the same light output and its lifetime is much longer than that of an incandescent lamp. However, current CFLs have the following drawbacks: (1) the line current drawn from …
-
Design of IC controller for dimmable compact fluorescent lamps with closed-loop control
<p>The use of Compact Fluorescent Lamps (CFLs) is growing rapidly worldwide not only because of its small size, but also because it saves more energy compared to the standard incandescent light bulb. In this thesis, an improved phase-controlled dimmable electronic ballast for CFLs is developed. The …
-
AN INVESTIGATION OF THE RESPONSE OF INCANDESCENT LAMPS AND COMPACT FLUORESCENT LAMPS TO VOLTAGE FLUCTUATION
… of tests that were performed on incandescent lamps and compact fluorescents lamps (CFLs) in order to observe their sensitivity to voltage fluctuations that can occur on a power system. The lamps tested were designed for use in a 120V, 60Hz system. They are models that are commonly available in …
-
Tailored recovery of rare earth elements from fluorescent lamps industry leachates towards new catalytic applications
As terras raras são elementos químicos conhecidos como REE (do inglês, Rare Earth Elements), essenciais em diversas aplicações tecnológicas que fazem parte do quotidiano. A procura destes elementos químicos tem vindo a aumentar devido ao seu grande consumo e aplicações. Os zeólitos são …
-
Effect of mechanical vibrations on light emitting diode luminaires
In this work, a LED and two types of Compact fluorescent lamps were investigated for the intensity variation due to mechanical vibrations in the range of 0 to 30 HZ. In general, subjecting the lamps to 24-hour vibration affects the total intensity percentage variations of peak intensities after …
-
Lamp modeling and design of IC controller for dimmable electronic ballast
… surely ease energy consumption. The efficacy of fluorescent lamps is 4 times higher than that of traditional light bulbs (80 lm/W vs 20 lm/W), while electronic ballasts excel over magnetic ballasts by 10% to 15% due to switching at high frequency (~ 30kHz) rather than at line frequency. …
-
Piezoelectric Transformer Characterization and Application of Electronic Ballast
… ballasts have been developed for use in fluorescent lamps. The piezoelectric transformer is a combination of piezoelectric actuators as the primary side and piezoelectric transducers as the secondary side, both of which work in longitudinal or transverse vibration mode. These actuators …
-
Estudo sobre a situação da logística reversa de lâmpadas fluorescentes conforme estabelecido pelo Plano Nacional de Resíduos Sólidos no Brasil
… and also regarding the proper disposal of fluorescent lamps by a large part of those surveyed. Thus, a proposed solution would be the implementation of environmental education programs, combined with investments in public policies, aiming to raise awareness among the population about the …
-
Modeling of fluorescent lamp for design of electronic ballast
The efficiency and life-span of fluorescent lamps can be greatly improved by the usage of electronic ballasts instead of conventional inductive chokes. These electronic ballasts are also much lighter and more compact. They are usually based on resonant power converter topologies and are difficult …
-
Fluorescencinės lempos koreliuotos spalvinės temperatūros ir jos skotopinio/fotopinio šviesos našumo santykio nustatymas /
… of light, the principles of the operation of fluorescent lamps and production technology, photopic and scotopic vision. The main photometric and radiometric dimensions are discussed. In the second part (experimental) - the main characteristics of the fluorescent lamp are determined and …
-
Experimental and Simulation Evaluation of Alternative Interior and Exterior Lighting Solution for Virginia Tech
… was experimentally compared with the existing fluorescent lamps. Performances of the fluorescent and LED lamps were analyzed for selected parameters such as the quality, color and quantity of the light. The annual energy consumption and utility cost of a representative building on the Virginia …
-
Caracterización armónica de dispositivos de iluminación de eficiencia energética
… installations (i.e., high intensity discharge lamps (HIDLs) with magnetic ballast, compact fluorescent lamps (CFLs) with integrated ballast, and solid state lighting light emitting diodes (SSL-LEDs) luminaries). The aim of these models and the developed numerical tools is to characterize their …
-
Co-cristalização da curcumina com d-manitol: caracterização e aplicações sobre larvas do Aedes aegypti (Linnaeus, 1762)
… test (of the most effective formulation) in fluorescent lamps (0.5 mW/cm²) 24h. For efficacy trials, the formulations were used at concentrations between 0.00625; 0.0125; 0.025; 0.05; 0.1; 0.2; 0.4; 0.8 mg.L-1 with 18W white fluorescent lamps, 0.5 mW/cm2 irradiance and after 24h larvae …
-
Phase-controlled dimmable CFL with PPFC and switching frequency modulation
… of dimmable electronic ballast for compact fluorescent lamps is presented. Popular triac dimmer is used for dimming control, while phase-control methodology is employed in eliminating extra control wires. Various types of passive power factor correctors are examined in replacing active power …
Page 1 of 6