Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 56 for “"Fluorescent sensor"”.
-
Fluorescent sensor development through surface functionalisation
… devices with application to biological sensing. Fluorescent sensors are commonly used to detect biological analytes through a change in fluorescence, a concept introduced in Chapter 1. However, the successful application of fluorescent sensors to biological systems is inhibited by a number of …
-
Fluorescent Sensor Materials based on 3d Transition Metal Complexes
… of this work was the design of photoluminescent sensor materials based on 3d transition metal complexes composed of Schiff base-like ligands. In this work, the focus was on the influence of axial coordination on the emission properties. In the first project the effect of coordination-induced spin …
-
Synthesis of Novel Antimycobacterials and a Fluorescent Sensor for Simple Carbohydrates
… second objective was the synthesis of a simple fluorescent receptor for simple carbohydrates. A receptor using anthracene as the fluorophore has been completed demonstrating an improved yield over previous methods. This receptor is the first to show selectivity for myo-inositol over other …
-
Development of a novel fluorescent sensor for detection of 4-hydroxynonenal
… byproduct is the target analyte for our proposed sensor. In this project, the goal is to design a turn on fluorescent sensor that could quantitate 4-HNE levels with high selectivity in serum. Toward this aim, we plan to develop a thiol-based sensor that enables us to take advantage of thiol- …
-
Enhancement of a fluorescent sensor for monitoring glucose concentration in diabetic patients
… with little invasion into the body. Previous fluorescent chemical assays, based on the affinity binding reaction between Concanavalin A protein and dextran, performed well but suffered from limited dermal penetration. In this work, a novel replacement for the dextran molecule (glycosylated …
-
Development of a cross-reactive fluorescent sensor array for the detection of liver fibrosis
Abstract not currently available.
-
Optimization and application of a high-performance genetically-encoded fluorescent sensor for membrane voltage imaging
… a high-performance genetically-encoded voltage sensor to probe the electrical activity of excitable cells with high sensitivity and spatiotemporal precision. When applied to the striatum, SomArchon allowed us to reveal critical insight into how delta oscillations, and in particular, ChIs, …
-
DEVELOPMENT OF A BODIPY-BASED MILK FAT FLUORESCENT SENSOR AND ITS APPLICATION IN SELECTIVE MILK FAT QUANTITATION AND MILK QUALITY CONTROL
THE FIRST FLUORESCENT SENSOR FOR MILK FAT WAS DEVELOPED. IT EXHIBITS MAGNIFICENT, YET SELECTIVE TURN-ON FEATURE TOWARDS FAT MOLECULES IN COMPLICATED MILK MATRIX, THROUGH THE DISAGGREGATION-INDUCED EMISSION MECHANISM. FURTHER CONSTRUCTION OF A HANDY FLUORESCENCE MILK FAT DETECTOR PROVIDES A …
-
An aptamer-based sensor for the detection of antimalarial drugs
… reports the development of a low-cost, rapid, fluorescent sensor for the specific detection of piperaquine and mefloquine. In order to do this, DNA aptamers were identified that bind and differentiate between small molecule partner drugs. These aptamers were selected from a library of …
-
Development of fluorescent sensors for the detection of hydrophobic amines and glycolipids
A novel fluorescent sensor was designed and synthesized to detect hydrophobic amines and was used to extract them from synthetically prepared vesicles. This sensor had a higher affinity for diamines than primary amines, providing a fluorescence decrease upon binding both analytes. This sensor bound …
-
Remote sensing of micro pollutants in water using a fibre optic analysis system
… of phenols in groundwater using a fibre optic fluorescent sensor system is discussed. Two sensor designs are discussed, modelled and experimentally evaluated. One, consisting of a single source fibre and nine ‘return’ fibres used with a deuterium lamp source, double monochromator and …
-
Targeting PCNA with Cell and Nuclear Permeable p21-derived Peptides
… sequence was used to develop a peptide-based fluorescent sensor for PCNA which is discussed in Chapter Four. Previous work in our lab identified the truncated p21-derived peptide, p21(143-155) (¹⁴³RQTSMTDFYHSK¹⁵⁵), termed P1 as a lead inhibitor of PCNA due to its short length and high affinity …
-
In vitro selection and characterization of mono-, di-, and trivalent metal-dependent DNAzymes and their sensing applications
… Fe(III). We are in the process of designing a fluorescent sensor for Fe(II) based on the H5 DNAzyme. This sensor will be tested for intracellular imaging of Fe(II) in living cells. To obtain Fe(III)-dependent DNAzymes, different selection protocols and selection conditions were investigated. In …
-
Synthesis and Luminescent Properties of Graphene Quantum Dots (GQDs) for Fluorescence Quenching by Titanium Dioxide Nanoparticles in Water Analysis
… under ultrasonication. GQDs were next added as a fluorescent sensor probe to measure the quenching of its emission intensity by the PDA-coated nanoparticles. Data analysis by the Stern-Volmer equation followed a third-order polynomial fit that indicated static, dynamic and absorptive contributions …
-
Development of a pH sensitive coumarin based chemosensor
Fluorescent probes have found several uses in monitoring the physiological state of cells. Recently, the Glass lab has developed a fluorescent sensor capable of binding norepinephrine in chromaffin cell vesicles. This sensor is based on coumarin aldehyde compounds which have been shown to …
-
IDENTIFICATION AND QUANTIFICATION OF IONIC POLLUTANTS IN ENVIRONMENTAL WATER
… In chapter 2, a DNA-based molecular beacon fluorescent sensor was demonstrated for the detection of a cationic pollutant, namely Hg2+, with tunable detection range. This sensor can easily detect Hg2+ in the presence of other metal ions. It is potentially useful for on-site detection in …
-
Development of microplate screening system and construction of fluorescein-based library
… of fluorescence imaging research. However, novel fluorescent sensor design is still difficult and time consuming, as little knowledge is well understood in this field. There is a pressing need to development new approaches to design fluorescent sensors. Diversity Oriented Fluorescence Library …
-
RATIOMETRIC NEAR-INFRARED FLUORESCENT PROBES FOR THE SENSITIVE DETECTION OF INTRACELLULAR pH AND BIO-THIOLS IN LIVE CELLS
… years, fluorescence sensing and imaging based on fluorescent probes has been developed as an imperative technique due to the merits including excellent sensitivity, operational simplicity, instant time effectiveness and outstanding selectivity in the research areas such as mineralogy, gemology, …
-
Design of Antibacterial Prochelators to Target Drug-Resistant Bacteria
… bacteria compared to clinical antibiotics.</p><p>Fluorescent sensors are a powerful tool for detecting small concentrations of biological analytes. Two analogs of a ratiometric fluorescent sensor were designed and synthesized to monitor cellular concentrations of copper and iron. These sensors …
Page 1 of 3