Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 28 for “"Fluoroscopic images"”

  1. DEVELOPING A PREDICTIVE MODEL OF HEART WALL MOTION IN FLUOROSCOPIC IMAGES

    … surgery. IGS combines pre- and perioperative images acquired from different imaging modalities to give the surgeon a more complete view of the internal organs. These modalities include computed tomography, magnetic resonance imaging, and fluoroscopy, to name a few. Fluoroscopy is also known as …

    clemson Repository record for DEVELOPING A PREDICTIVE MODEL OF HEART WALL MOTION IN FLUOROSCOPIC IMAGES (opens in a new tab)

  2. Real-time dosimetry for prostate brachytherapy using TRUS and fluoroscopy

    … (VCC) for prostate brachytherapy. The TRUS and fluoroscopic images axe fused using a, single fluoroscopic image of the TRUS probe. The tip of each needle, used to implant the seeds, is identified in TRUS images. Using the needle tip location and the known entry point of the needle in the needle …

    ubc Repository record for Real-time dosimetry for prostate brachytherapy using TRUS and fluoroscopy (opens in a new tab)

  3. Patient-specific technology for in vivo assessment of 3-D spinal motion

    … clinical diagnostic techniques such as fluoroscopic imaging or CT scans are limited due to their static and/or planar measurements which may not be able to capture all neurological pathologies. More advanced diagnostics have proven successful in assessing 3-D patient-specific spinal …

    uiuc Repository record for Patient-specific technology for in vivo assessment of 3-D spinal motion (opens in a new tab)

  4. Development of a Surgical Assistance System for Guiding Transcatheter Aortic Valve Implantation

    … and anatomical valve landmarks with live 2D fluoroscopic images. The 3D aortic mesh model and landmarks are reconstructed from interventional angiographic and fluoroscopic C-arm CT system, and a target area of valve implantation is automatically estimated using these aortic mesh models. Based …

    qucosa-diss Repository record for Development of a Surgical Assistance System for Guiding Transcatheter Aortic Valve Implantation (opens in a new tab)

  5. 2D-3D Registration Methods for Computer-Assisted Orthopaedic Surgery

    … orthopaedic surgery (CAOS). Preoperative 3D images and surgical plans need to be mapped to the patient in the operating room before they can be used to augment the surgical intervention, and this task is generally fulfilled by using 2D-3D registration which spatially aligns a preoperative 3D …

    queens Repository record for 2D-3D Registration Methods for Computer-Assisted Orthopaedic Surgery (opens in a new tab)

  6. Detection and 3D Localization of Surgical Instruments for Image-Guided Surgery

    … (specifically, Kirschner wires [K-wires]) in fluoroscopic images acquired within routine workflow. The detection method uses a neural network (Mask R-CNN) for segmentation and keypoint detection of K-wires in fluoroscopy, and correspondence of keypoints among multiple images is established by …

    jhu Repository record for Detection and 3D Localization of Surgical Instruments for Image-Guided Surgery (opens in a new tab)

  7. Analysis of a Fluoro Noise Reduction Technique

    … addresses a technique that reduces noise in fluoroscopic images and permits operation of the x-ray systems at lower dose levels.

    marquette Repository record for Analysis of a Fluoro Noise Reduction Technique (opens in a new tab)

  8. Innervation of the Posterior Aspect of the Sacroiliac Joint: An Anatomical Basis for Diagnostic Blocks and Radiofrequency Ablation Techniques for Sacroiliac Joint Pain

    … were exposed, radiopaque wires sutured to LBs, fluoroscopic images obtained, lesions mapped on the fluoroscopic images using ImageJ, and LB capture rates quantified. The bipolar techniques, including the proposed technique, had a greater mean LB capture rate than the monopolar techniques. The 3 …

    toronto-retro Repository record for Innervation of the Posterior Aspect of the Sacroiliac Joint: An Anatomical Basis for Diagnostic Blocks and Radiofrequency Ablation Techniques for Sacroiliac Joint Pain (opens in a new tab)

  9. 3D Imaging for Planning of Minimally Invasive Surgical Procedures

    … diseases and are performed under 2D fluoroscopic guidance with a C-arm system. 3D multidetector row computed tomography (MDCT) images are routinely used for preprocedural planning and postprocedural follow-up. For preprocedural planning, the ability to integrate the MDCT with …

    ohiolink Repository record for 3D Imaging for Planning of Minimally Invasive Surgical Procedures (opens in a new tab)

  10. 3D Reconstruction of Patient Specific Bone Models for Image Guided Orthopaedic Surgery

    … procedures currently solely relies on 2D x-ray/fluoroscopic images. This research aims to assist orthopaedic surgeons in all steps of the femur fracture reduction procedure by introducing 3D anatomical visualisation. Studies conducted on femur fracture reduction has confirmed that computer-aided …

    auckland-ms Repository record for 3D Reconstruction of Patient Specific Bone Models for Image Guided Orthopaedic Surgery (opens in a new tab)

  11. Multimodal Learning-Based Frameworks for Sensor-Free Force-Aware Perception and Autonomous Navigation in Cardiac Catheterization

    … contact forces directly from stereo catheter images without reliance on physical sensors or explicit mechanical modeling. This is extended to a multitask encoder–decoder architecture that simultaneously performs catheter segmentation and force estimation from biplane fluoroscopic images within …

    concordia

  12. IMAGE-GUIDED ROBOT-ASSISTED ANKLE JOINT REDUCTION: SYSTEM INTEGRATION AND PRECLINICAL TRIAL

    … to localize bone and robot positions in fluoroscopic images. Through end-to-end evaluations and pre-clinical trials on ankle cadaver samples, we demonstrate the effectiveness of our system in achieving accurate reduction outcomes. Our evaluations highlight the robustness and reliability …

    jhu Repository record for IMAGE-GUIDED ROBOT-ASSISTED ANKLE JOINT REDUCTION: SYSTEM INTEGRATION AND PRECLINICAL TRIAL (opens in a new tab)

  13. Factors Affecting Postural Reduction in Posterior Surgery for Thoracolumbar Burst Fracture

    … Postural reduction was evaluated using C-arm fluoroscopic images and regarded as insufficient when the lateral Cobb angle was ≥20 degrees or AP Cobb angle ≥10 degrees. Clinical characteristics including sex, age, body mass index, time to operation, injury level, and neurological injury, as …

    ajou Repository record for Factors Affecting Postural Reduction in Posterior Surgery for Thoracolumbar Burst Fracture (opens in a new tab) Embargoed until 9999-12-31

  14. Design and development of robotic system for endovascular procedures

    … force feedback from the tool. Even though fluoroscopic images like X-rays provide a temporary solution, the perceptive of depth is not available in these visual feedback and the prolonged hazardous radiations do not provide a safer working environment for surgeons. A tele-operated robotic …

    uiuc Repository record for Design and development of robotic system for endovascular procedures (opens in a new tab)

  15. Automated segmentation of lumbar vertebrae for the measurement of spine kinematics

    … a number of studies on vertebral extraction from fluoroscopic images, varying from manually locating the vertebral landmarks to template matching. However, the former method poses problems of repeatability which can lead to errors in kinematic analysis, while the latter cannot cope with the large …

    soton Repository record for Automated segmentation of lumbar vertebrae for the measurement of spine kinematics (opens in a new tab)

  16. Design and Evaluation of Novel Devices to Facilitate Long Bone Fracture Reconstruction

    … wire anteroposterior (AP) alignment when lateral images are acquired to obtain accurate K-wire positioning in the sagittal plane. FLEX FiRST (FLEXible Fracture Reduction Steerable Telescoping) Wire is a flexible endoscopic device whose insertion is guided by a proximal joy-stick like controller …

    toronto-retro Repository record for Design and Evaluation of Novel Devices to Facilitate Long Bone Fracture Reconstruction (opens in a new tab)

  17. Improving the electrocardiographic inverse solution by Kalman filtering

    … model was determined from multiplane fluoroscopic images. The boundary element method was then applied to solve the boundary value problem and determine a linear relationship between endocardial and probe potentials. The Paige and Saunders solution of the Duncan and Horn formulation …

    rice Repository record for Improving the electrocardiographic inverse solution by Kalman filtering (opens in a new tab)

  18. Quantitative Movement Analysis in Endovascular Surgical Tasks for Objective Determination of Skill

    … used to track catheter tip movements from the fluoroscopic images when performing tasks on the simulator. Several motion-based performance measures that have been shown to reliably assess skill in other domains were computed and tested for correlation with subjective data that were …

    rice Repository record for Quantitative Movement Analysis in Endovascular Surgical Tasks for Objective Determination of Skill (opens in a new tab)

  19. Validation of high density electrode arrays for cochlear implants: a computational and structural approach

    … human cadaver cochleae using the TFM/IP devices. Fluoroscopic images recorded the insertion, and post analysis 3D CT scans and histology were conducted on the specimens. Only three of the ten implanted TFM/IPs suffered severe delamination. This statistic for scala vestibuli excursion is not an …

    gatech Repository record for Validation of high density electrode arrays for cochlear implants: a computational and structural approach (opens in a new tab)

  20. Intraoperative use of c-arm cone beam CT for quality assurance of low dose rate prostate brachytherapy dose delivery

    … the procedure, transrectal ultrasound (TRUS) and fluoroscopic images (acquired using a mobile C-arm fluoroscopic X-ray system) are used to guide and visually assess implant quality, but do not provide accurate quantitative dosimetry. Thus, the patient undergoes a CT scan after the implantation is …

    ubc Repository record for Intraoperative use of c-arm cone beam CT for quality assurance of low dose rate prostate brachytherapy dose delivery (opens in a new tab)

Page 1 of 2