Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 441 for “"Flux measurements"”

  1. Ship Borne Direct Eddy Covariance Flux Measurements

    Ship borne direct eddy covariance flux measurements of momentum, heat (latent and sensible), and the trace gas CO2, were conducted during three open ocean experiments. The methods for data analysis and interpretation were adapted from the literature, and reviewed carefully. Two major sources of …

    galway Repository record for Ship Borne Direct Eddy Covariance Flux Measurements (opens in a new tab)

  2. Air-sea flux measurements over the Southern Ocean

    … near-continuous and autonomous turbulent air-sea flux estimates from the research vessel RRS James Clark Ross. Supporting meteorological and sea-state measurements were also made, with the objective of improving air-sea flux parameterisations. Making turbulence measurements from a ship is …

    whiterose Repository record for Air-sea flux measurements over the Southern Ocean (opens in a new tab)

  3. Diamagnetic flux measurements on the STOR-M tokamak

    Diamagnetic measurements of poloidal beta have been performed in the STOR-M tokamak by a flux loop placed exterior to the vacuum chamber. Poloidal beta is defined as the ratio of plasma kinetic pressure to poloidal magentic field pressure. Compensation for the vacuum toroidal field has been …

    sask Repository record for Diamagnetic flux measurements on the STOR-M tokamak (opens in a new tab)

  4. Hydrogen Sulfide Flux Measurements And Dispersion Modeling From Constr

    … gas emission rates from landfills is the flux chamber method. Typically the flux chamber is a cylindrical enclosure device with a spherical top which limits the gas emission area. Pure zero grade air is introduced into the chamber, allowed to mix with emitting gases captured from the …

    ucf Repository record for Hydrogen Sulfide Flux Measurements And Dispersion Modeling From Constr (opens in a new tab)

  5. CO2 and Isotope Flux Measurements above a Spruce Forest

    … of the carbon mass balances of ecosystems. Such measurements require a high degree of quality control in order to prevent systematic errors. The determination of the annual sum of NEE and filling of data gaps is complicated by characteristic diurnal and seasonal variation in the governing gross …

    bayreuth Repository record for CO2 and Isotope Flux Measurements above a Spruce Forest (opens in a new tab)

  6. Investigating spatial representation of micrometeorological flux measurements over agroecosystems

    A challenge with micrometeorological flux measurements is determining whether they represent field spatial variability. Often only one tower characterizes agricultural fluxes, so we used three towers (co-located, 50 m, and 100 m apart) to evaluate the spatial capability of eddy covariance to …

    manitoba Repository record for Investigating spatial representation of micrometeorological flux measurements over agroecosystems (opens in a new tab)

  7. Transcriptional profiling and flux measurements of polyhydroxybutyrate production in Synechocystis

    (cont.) to determine the CO₂ uptake rates and PHB production rates of strains engineered for enhanced CO₂ fixation and PHB production respectively.

    mit Repository record for Transcriptional profiling and flux measurements of polyhydroxybutyrate production in Synechocystis (opens in a new tab)

  8. Comparison of Agricultural Area Source Ammonia Gas Concentration and Flux Measurements

    … gas phase concentration and evaluation of system fluxes. This was accomplished by measuring NH3 emitted from area sources within two dairies, one located in south-central Idaho and another in central California. The measurement techniques utilized included: an array of passive diffusion samplers, …

    utahstate Repository record for Comparison of Agricultural Area Source Ammonia Gas Concentration and Flux Measurements (opens in a new tab)

  9. Carbon dioxide flux measurements from a coastal Douglas-fir forest floor

    … soil and the atmosphere. During the year 2000, measurements of forest floor CO₂ flux and below-ground CO₂ storage were obtained beneath the canopy of a 33-m tall coastal temperate Douglas-fir forest. The study took place at a micrometeorological tower flux site in operation since late 1997 …

    ubc Repository record for Carbon dioxide flux measurements from a coastal Douglas-fir forest floor (opens in a new tab)

  10. Turbulent heat flux measurements over the Greenland, Norwegian and Barents Seas

    Turbulent heat fluxes in the Greenland, Norwegian and Barents Seas during March 1988, February and March 1989, November 1991 and January and March 1992 have been calculated with the bulk method using shipboard-based measurements of wind speed, air and sea surface temperatures, relative humidity and …

    nps Repository record for Turbulent heat flux measurements over the Greenland, Norwegian and Barents Seas (opens in a new tab)

  11. Flux Measurements of Volatile Organic Compounds from an Urban Tower Platform

    A tall tower flux measurement setup was established in metropolitan Houston, Texas, to measure trace gas fluxes from both anthropogenic and biogenic emission sources in the urban surface layer. We describe a new relaxed eddy accumulation system combined with a dual-channel gas chromatography - …

    tamu Repository record for Flux Measurements of Volatile Organic Compounds from an Urban Tower Platform (opens in a new tab)

  12. Characterizing 3D Hypersonic Boundary Layers with Transient Surface Heat Flux Measurements

    … thermography and high-frequency pressure measurements in wind tunnels. A new heat flux analysis was developed incorporating 3D effects to eliminate the uncertainties incurred by lower dimensional methods and provide global heat flux data. The BOLT II, side A flight experiment, which …

    tamu Repository record for Characterizing 3D Hypersonic Boundary Layers with Transient Surface Heat Flux Measurements (opens in a new tab)

  13. Time-resolved heat flux measurements of the turbulent junction vortex system

    A rapid-response thin-film heat flux sensor was used to measure time-resolved unsteady heat flux in a complex junction vortex flow. This sensor, called the Heat Flux Microsensor, was used with a hot-wire anemometer to make simultaneous measurements of velocity and surface heat flux. The results …

    vt Repository record for Time-resolved heat flux measurements of the turbulent junction vortex system (opens in a new tab)

  14. NEUTRON FLUX MEASUREMENTS FOR UNCERTAINTY QUANTIFICATION AT THE MCMASTER NUCLEAR REACTOR

    … the radiopharmaceutical industry. As the neutron flux dictates in-core processes that are crucial both to reactor operations and isotope production, highly precise measurements of this value are generally required to optimize and validate reactor physics analyses and day-to-day operations. …

    mcmaster Repository record for NEUTRON FLUX MEASUREMENTS FOR UNCERTAINTY QUANTIFICATION AT THE MCMASTER NUCLEAR REACTOR (opens in a new tab)

  15. Ground-level atmospheric neutron flux measurements in the 10-170 MeV range

    We report the results of ground level neutron measurements in the energy range of 10-170 MeV by the neutron double scatter telescope developed at the University of New Hampshire. Measurements were carried out at different altitudes and latitudes for the first time using the same telescope, yielding …

    unh-thes Repository record for Ground-level atmospheric neutron flux measurements in the 10-170 MeV range (opens in a new tab)

  16. Neutron Flux Measurements and Calculations in the Gamma Irradiation Facility Using MCNPX

    The gamma irradiation facility at the High Flux Isotope Reactor (HFIR)is used to deliver a pure gamma dose to any target of interest. in addition to the gamma rays, there are neutron impurities due to spontaneous fissions, gamma neutron reactions, and alpha neutron reactions. Steps have been taken …

    ohiolink Repository record for Neutron Flux Measurements and Calculations in the Gamma Irradiation Facility Using MCNPX (opens in a new tab)

Page 1 of 23