Results 1 to 20 of 62 for “"Fluxgate"”
-
RTD FLUXGATE MAGNETOMETERS
Fluxgate magnetometers have always been of interest to the technical and scientific communities as practical and convenient sensors for vector magnetic field measurements in the range of microtesla requiring a resolution of hundreds of picotesla at room temperature, and they find applicability in …
-
The theory of fluxgate sensor systems
In recent years, the fluxgate sensor system has become increasingly important for the measurement of magnetic fields. It has become the instrument of choice for some aeronomy research programs, for ocean bottom deployment and for vessel detection by seafloor sensors. It has considerable potential …
-
Fluxgate sensors for a spinner magnetometer
Noise sources in a Schonstedt spinner magnetometer, the primary laboratory instrument used in paleomagnetic research, and various methods for dealing with them are investigated theoretically and experimentally. Based on the results, an instrument is designed and constructed which replaces the …
-
Experimental investigations of a recent fluxgate theory
A recent theory describes the fluxgate magnetometer as a modulated inductor. In that theory, hysteresis and demagnetization are implicitly incorporated in the sense-coil inductance, an easily measured quantity. In this thesis, the principle equation of that theory is experimentally tested. …
-
Simulation and Optimization of Micromachined Magnetic Fluxgate Sensors
<p>Fluxgate sensors are one of the most versatile magnetic field sensors, offering very reliable field measurement from mT to sub uT region, with very high resolution. Vector magnetic field measurements of better sensitivity are only possible with quantum affects based magnetometer ‘SQIUD’ (super …
-
The fluxgate electric field meter : a feasibility study
The fluxgate electric field meter is a new solid-state instrument capable of measuring slowly varying electric fields equally well in an insulating or conducting medium with high resolution. The field meter determines the strength of an electric field by measuring the potential difference between …
-
Micromachined On-Chip Fluxgate Magnetometers with Low Power Consumption
… magnetic core, two novel CMOS-compatible micro fluxgate sensors have been developed and characterized in terms of low power consumption. In addition, a low-power interface integrated circuit has been developed and characterized for the developed sensors. Experiment shows that the magnetometer …
-
Study of Orthogonal Fluxgate Sensor in Terms of Sensitivity and Noise
… is to investigate the extreme of orthogonal fluxgate sensor in terms of sensitivity and noise. Novel multi-core sensing element materials using ferromagnetic micro-wires array has been designed and characterized, the physical mechanism of multi-core orthogonal fluxgate effects has been …
-
Contribution à la conception d'un électromètre dual des magnétomètres de type fluxgate
… innovant sans hacheur mécanique de type fluxgate électrique (FGE) en suivant le principe de la dualité entre paires de grandeurs physiques des domaines électriques et magnétiques, notamment celles intervenant dans le principe de mesure des fluxgates magnétiques (FGM). Or, l'analyse de la …
-
Desenvolvimento de um magnetômetro fluxgate para estudos de clima espacial e aeroespacial
In this work has been developed a magnetometer, which every step of conversion of signs and data acquisition has been realized by software, constituted solely of a sensor flux saturated, commercial. The magnetometer has got high sensitivity for measure magnetics fields of low intensity, static or …
-
Viaggio nel fluxgate a RTD: sfruttare la flessibilità e raggiungere la sostenibilità
Il magnetometro fluxgate viene studiato da più di 80 anni grazie alla sua capacità di rilevare e quantificare segnali (magnetici). E' in grado di rilevare campi magnetici statici e quasi statici da 1pT a 10nT. Però, questa struttura simile a un trasformatore con un core ferromagnetico circondato …
-
In Situ Observations of Pearl Pulsations and Development of a Low-Noise Fluxgate Magnetometer
… construction, and flight of a rocket-borne fluxgate magnetometer, and the examination of Pc1 pearl pulsations using data from the Van Allen Probes and MMS missions. Our first concentration regards the design and fabrication of an improved fluxgate magnetometer. The instrument makes use of an …
-
Nano/Femtosecond laser processing in developing nanocrystalline functional materials for multi-core orthogonal fluxgate sensor
In developing magnetic sensing elements, the sensitivity of magnetic sensors have been found to increase exponentially when multi-core structures are used as sensing elements. In this project, multi-core structured functional magnetic materials of extremely high permeability have been successfully …
-
Étude et développement d’un capteur fluxgate 3D pour la mesure à haute résolution de la signature magnétique de navires
… drone volant comprenant un capteur magnétique (fluxgate). L’objet de la thèse est de faire l’étude et le développement de ce capteur. D’abord, le circuit d’excitation a été étudié, puis, nous avons mis au point le circuit de traitement de signal. Nous nous sommes ensuite concentrés sur la …
-
Application of inertial sensors and flux-gate magnetometer to real-time human body motion capture
… for azimuth drift using a three-axis fluxgate magnetometer. The magnetometer capable of azimuth drift compensation since its sensitive axis is not collinear with the local vertical. This thesis includes a program for simulating the operation of a fluxgate magnetometer in C++. The …