Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 30 for “"Foot clearance"”

  1. Characterising intra- and inter-limb gait stability using minimum foot clearance

    … gait cycle from treadmill walking. The minimum foot clearance (MFC) during the swing phase of gait is an essential event that reveals two things: 1) how the locomotor system achieves control over many degrees of freedom when performing this spatial end point trajectory task while at the same …

    vu-aus Repository record for Characterising intra- and inter-limb gait stability using minimum foot clearance (opens in a new tab)

  2. Foot clearance in young and older adults when negotiating an obstacle.

    … obstacles when walking is a common placing the foot close to the obstacle. Objective: Thesis aim was to determine when crossing an obstacle if: a) the repeatability of foot clearance parameters; b) foot clearance parameters were symmetrical; c) there were a difference in foot clearance …

    essex Repository record for Foot clearance in young and older adults when negotiating an obstacle. (opens in a new tab)

  3. An Exploratory Study of the Relationship between Minimum Foot Clearance and Real-World Trips

    … real-world trip risk remain unclear. Minimum foot clearance (MFC), defined as the minimum vertical distance between the foot and ground during mid-swing, has been widely used as a surrogate indicator of trip risk; however, empirical evidence directly linking MFC to real-world trips is limited …

    vt Repository record for An Exploratory Study of the Relationship between Minimum Foot Clearance and Real-World Trips (opens in a new tab)

  4. The horizontal-vertical illusion on stairs: optimising the visual appearance of stairs to reduce falls risk

    … the perceived riser height and stair ascent foot clearances. The illusion could help to reduce stair falls, though there are several unaddressed points which importantly could affect its intended use. 1) In its current form, the illusion may not be visually suitable for older adults, those …

    liverpool-jm Repository record for The horizontal-vertical illusion on stairs: optimising the visual appearance of stairs to reduce falls risk (opens in a new tab)

  5. Design and implementation of MEMS biomechanical sensors for real-life measurements of gait parameters

    Foot clearance above the ground during walking is an important clinical and rehabilitation gait analysis parameter. Current bulky and laboratory environment based instruments are not suitable for measurement in the natural environment such as in the outdoors. This research analyses three promising …

    vu-aus Repository record for Design and implementation of MEMS biomechanical sensors for real-life measurements of gait parameters (opens in a new tab)

  6. Effect of aging on gaze, stepping behaviour, balance control and head posture during stair negotiation

    … and highlighted stair edges led to increased foot clearance in all groups. For stair descent, HROA demonstrated smaller foot clearance than LROA and highlighted stair edges improved balance in LROA and HROA. Thirdly, head posture was studied in YA, LROA and HROA. Compared to walking, LROA and …

    birmingham Repository record for Effect of aging on gaze, stepping behaviour, balance control and head posture during stair negotiation (opens in a new tab)

  7. RISK DETECTION FOR THE PREVENTION OF FALLS ON STAIRS IN OLDER PEOPLE

    … environment. The fall risk parameters were foot clearance and foot contact length ratio. A sensor insole was designed to detect foot contact length ratio (foot overhang) using force-sensitive resistors. Two distance sensors (VL6180X) were attached to the shoe to detect foot clearance for …

    liverpool-jm Repository record for RISK DETECTION FOR THE PREVENTION OF FALLS ON STAIRS IN OLDER PEOPLE (opens in a new tab)

  8. A Comprehensive Strategy for Controlling the Hip and Knee with a Muscle-Driven Exoskeleton for Mobility after Paraplegia

    … can be inadequate and result in inconsistent foot-floor clearance, increasing the risk of tripping or falling. The stand-to-sit (STS) transition was also poorly controlled and resulted in high impact with the seating surface. Therefore, we hypothesized that a HNP with context-dependent …

    ohiolink Repository record for A Comprehensive Strategy for Controlling the Hip and Knee with a Muscle-Driven Exoskeleton for Mobility after Paraplegia (opens in a new tab)

  9. Understanding Gait Control Dynamics: Ageing Effects on Falling Risks

    … gait events are toe-off, heel contact, minimum foot clearance (MFC) and minimum lateral margin (MLM). Dynamic balance at these four gait events were examined to characterise biomechanical evidence in older adults’ walking patterns to understand the frequent occurrence of falls. Falls prevention …

    vu-aus Repository record for Understanding Gait Control Dynamics: Ageing Effects on Falling Risks (opens in a new tab)

  10. Conspicuity of Walkway Height Changes

    … trip events start is when an observer's minimum foot clearance (MFC) is smaller than the height change. One reason why the observer might not change their MFC in response to the height change is that the height change is not conspicuous. An important aspect of conspicuity is illuminance levels. …

    clemson Repository record for Conspicuity of Walkway Height Changes (opens in a new tab)

  11. The evaluation of and comparative evidence for two types of interventional devices for foot-drop of central neurological origin

    Introduction This thesis focusses on ankle foot orthoses (AFO) and functional electrical stimulation (FES) for the correction of foot-drop. It consists of two parts linked through identification of three gaps in the knowledge base: 1) limitations in device design, 2) limitations in device …

    salford Repository record for The evaluation of and comparative evidence for two types of interventional devices for foot-drop of central neurological origin (opens in a new tab)

  12. The design, construction, and calibration of a flexible control rod for the V.P.I. subcritical reactor

    … reactor is complicated by the limiting two foot clearance between the top of the reactor and the ceiling. Within this space it is necessary to insert and operate an effective seven foot, solid, straight rod along the vertical axis of the reactor. The problem is overcome by cutting the rod in …

    vt Repository record for The design, construction, and calibration of a flexible control rod for the V.P.I. subcritical reactor (opens in a new tab)

  13. Assessment of Foot Signature Using Wearable Sensors for Clinical Gait Analysis and Real-Time Activity Recognition

    … includes wireless inertial sensors worn on the foot, that record data unobtrusively over long periods of time without interfering with subject's walking. Signal processing algorithms are presented for the automatic calibration and online virtual alignment of sensor signals, the detection of …

    epfl Repository record for Assessment of Foot Signature Using Wearable Sensors for Clinical Gait Analysis and Real-Time Activity Recognition (opens in a new tab)

  14. PRIME : A Prediction Algorithm, an Indicator, and a New Method for implementing Fall Preventing Strategy in a Hip Assist Soft Exosuit.

    … prevent trip related falls by increasing minimum foot clearance by assisting hip joint movements while stepping over obstacles to prevent foot obstacle contact and hence trip. Along with fall prevention, this exosuit will also assist the elderly in day to day lives and help overcome physical …

    ohiolink Repository record for PRIME : A Prediction Algorithm, an Indicator, and a New Method for implementing Fall Preventing Strategy in a Hip Assist Soft Exosuit. (opens in a new tab)

  15. Obstacle Avoidance. The acquisition and performance of a locomotor task.

    … approaching obstacle, without touching it. Foot clearance over the obstacle, number of obstacle hits, changes in muscle activity and joint kinematics were measured and analyzed. The main goals of the experiments were to investigate (1) the underlying mechanisms involved in learning to adapt …

    radboud Repository record for Obstacle Avoidance. The acquisition and performance of a locomotor task. (opens in a new tab)

  16. Design and Evaluation of a Novel Ankle Joint for an Ankle Foot Orthosis for Individuals with Drop-Foot

    … have had a stroke often ambulate with an ankle foot orthosis (AFO) to treat drop-foot, a common impairment preventing active ankle dorsiflexion. AFOs limit ankle plantarflexion or drop-foot, but also restrict ankle motion that introduces additional gait pathologies during ambulation. The goal of …

    marquette Repository record for Design and Evaluation of a Novel Ankle Joint for an Ankle Foot Orthosis for Individuals with Drop-Foot (opens in a new tab)

  17. Predictive Simulations of Gait and Their Application in Prosthesis Design

    … was energy optimal for certain tasks and nonzero foot clearance was energy efficient. The approach was then applied to TTA gait to explain co-contraction of the upper-leg muscles on the prosthesis side. The results suggested that antagonistic co-contraction is energy optimal for human gait.

    ohiolink Repository record for Predictive Simulations of Gait and Their Application in Prosthesis Design (opens in a new tab)

  18. Investigation of the Effects of Prosthetic Knee Condition on Novice Transfemoral Amputee Runners

    … to run without a knee (prosthetic socket and foot are linked via a straight, non-articulating pylon) to increase stability. Research regarding unilateral TFA running with an unlocked versus locked prosthetic knee (approximately equivalent to the no-knee condition) with respect to energy cost …

    marquette Repository record for Investigation of the Effects of Prosthetic Knee Condition on Novice Transfemoral Amputee Runners (opens in a new tab)

  19. Functional Comparison of Conventional AFOs with the Dynamic Response AFO

    Ankle foot orthoses (AFOs) are commonly prescribed to provide stability and foot clearance for patients with weakened or injured musculature. The Dynamic Response AFO (DRAFO) was designed to improve proprioception at heel strike. The design includes a rigid outer shell with a cut out heel and a …

    marquette Repository record for Functional Comparison of Conventional AFOs with the Dynamic Response AFO (opens in a new tab)

  20. Neuromotor recovery of plantarflexor function after stroke: towards precision gait rehabilitation with a propulsion neuroprosthesis

    … neurostimulation to assist propulsion and foot clearance, which when impaired after stroke, are primary factors that reduce community walking and increase risk of falling. The first aim assesses biomechanical mechanisms underlying changes in walking speed and energy cost after gait training …

    bu Repository record for Neuromotor recovery of plantarflexor function after stroke: towards precision gait rehabilitation with a propulsion neuroprosthesis (opens in a new tab)

Page 1 of 2