Showing 1 to 20 of 25 for “"Foot drop"”.
-
Foot Drop Gait: Analysis and Assistive Torque Design
Foot drop is a gait abnormality where patients slap the ground with the front foot at initial contact instead of the heel. Most of the time, this problem is caused by neurological disorder. The muscle tibialis anterior, which is responsible for dorsiflexion and picking up the foot when contacting …
-
Evaluating Foot-drop Interventions for Multiple Sclerosis Using a Multimodal System
… with multiple sclerosis (pwMS) experiencing foot-drop. Foot-drop can dramatically impede mobility and clinicians routinely prescribe ankle-foot-orthosis (AFO) and functional electrical stimulation (FES) devices to alleviate its impacts on daily life. However, little is known about how these …
-
Sensor Fusion based Gait Recognition for Accurate Actuation of Foot Drop Stimulation
Foot drop is a walking (gait) disability resulting with defect in neural pathway to lower limb after a stroke or traumatic event. The foot drop patients mainly lack the forefoot lift (dorsiflexion) while swinging the foot forward. In some cases, excessive inward movement (inversion) during swing …
-
THE SAFETY AND POTENTIAL EFFECTIVENESS OF A NOVEL WEARABLE ANKLE ROBOT IN STROKE PATIENTS WITH FOOT DROP
… worldwide. About 20% of survivors experience foot drop. Current treatments are labor-intensive and non-standard. Rehabilitation robots have demonstrated potential. However, previous ankle robots are often bulky. Furthermore, studies are limited by small sample sizes and healthy participants. …
-
The effects of Functional Electrical Stimulation on motor-cognitive interference during gait in people with foot drop following stroke
… (FES) is commonly used for correction of foot drop due to stroke. At the start of the PhD, studies had shown FES increases walking speed. However, questionnaire-based studies found that users rated a reduction in effort and a reduced risk of tripping or falling as the two most important …
-
The evaluation of and comparative evidence for two types of interventional devices for foot-drop of central neurological origin
Introduction This thesis focusses on ankle foot orthoses (AFO) and functional electrical stimulation (FES) for the correction of foot-drop. It consists of two parts linked through identification of three gaps in the knowledge base: 1) limitations in device design, 2) limitations in device …
-
Muscular activation and corticospinal excitability adaptations to split crank cycling
Foot drop is a common motor impairment of the lower limb caused by Acquired Brain Injury (ABI) that can limit mobility and increase risk of falls. Split Crank (SC) cycling is proposed here as a novel paradigm to evoke functional neural plasticity and beneficial muscular adaptations to treat foot …
-
Gait analysis for AFO selection by using IMU sensor
Foot drop is a medical condition characterized by the paralysis if the nerve or weakness of the muscles that lift the front part of the foot. This could be due to a variety of reasons and can manifest either temporarily or chronically, one of the causes is stroke. In fact, it’s estimated that …
-
Use of the Bioness L300® Functional Electrical Stimulator in Acute Stroke Rehabilitation
… 150,000 people in the U.S. every year experience foot drop following a stroke, slowing their ambulation and increasing their falls risk. We explore whether the use of functional electrical stimulation (FES) to the common fibular nerve during acute rehabilitation can maximize ambulation gains. …
-
Design, characterization, and validation of a soft pneumatic exosuit for ankle-dorsiflexion assistance
… States every year, 65% experience hemiparesis. Foot drop is a common gait pathology in people with lower-limb paresis and is often caused by neuropathy of the peroneal nerve that innervates the muscles responsible for ankle dorsiflexion. Foot drop can impede toe clearance and increase the risk …
-
Effects of Bimodal Transcranial Direct Current Stimulation on Modulation of Spinal Circuitry in People with Chronic Post-Stroke Hemiparesis
… Stroke can lead to gait abnormalities such as foot drop. Foot drop can result from decreased corticospinal tract input to the ankle dorsiflexors and/or from exaggerated stretch reflexes on the soleus due to reduced reciprocal inhibition from spinal reflex pathways. Transcranial direct current …
-
Effects of two different types of ankle foot orthoses on gait outcomes in patients with subacute stroke
Ankle Foot Orthosis (AFO) is a commonly prescribed device to improve foot drop and gait in patients with stroke. The purpose of this study was to identify whether patients in the subacute stage of stroke, with foot drop, would have better gait outcomes when using a double adjustable AFO (DA AFO), …
-
TOWARD AMBULATORY ENHANCEMENT OF STROKE SURVIVORS VIA A UNILATERAL CABLE-DRIVEN EXOSKELETON
… from stroke-induced joint impairments like foot drop. Effective gait training significantly aids in their walking independence during rehabilitation. This thesis develops a specialized lower limb exoskeleton, SEAExo, for subacute stroke patients, assessing its efficacy in real-world clinical …
-
A surface electrode array-based system for functional electrical stimulation
… electrical stimulation (FES) system for foot drop correction. The thesis reports a series of studies on the design and development of an electrode array, describes how these results informed the design of a practical array and demonstrates methods for using this array in combination with …
-
Treadmill training augmented with real-time visualisation feedback and function electrical stimulation for gait rehabilitation after stroke : a feasibility study
… to stimulate the pretibial muscle for correcting foot drop problems, gastro-soleus for facilitating push-off, and quadriceps and hamstring for improving knee stability. Dynamic avatar movement and step length/ratio were displayed on a monitor, providing patients with real-time visual biofeedback. …
-
Performance of Hooked-End Superelastic Shape Memory Alloy and Steel Fibre Reinforced Concrete and Stiffness of Ankle Foot Orthosis With Superelastic Shape Memory Alloy Hinges
… layer. Applications of superelastic SMA in ankle foot orthoses (AFO) were examined in Chapters Six and Seven of this thesis. AFOs are orthotic devices used by patients who have an abnormal gait caused by conditions such as foot drop syndrome. A systematic review was conducted and the mechanical …
-
Feasibility of Extending an Artificial Salmon Spawning Stream, Marx Creek Near Hyder, Alaska
… system is sufficient to support a proposed 1,000-foot extension of Marx Creek. The extension would be constructed approximately 500 feet east of the existing channel, and would connect with the existing Marx Creek at a point downstream of the sediment-settling stream cell. The location of the new …
-
Comparison of an ankle-foot-orthosis and neuroprosthesis during level and non-level walking for individuals post-stroke
… gait analysis to compare the efficacy of the two foot drop treatments (ankle-foot-orthosis and neuroprosthesis) and to contrast the stimulation control of the two different neuroprosthesis sensors during level and non-level ambulation of post-stroke individuals. Eight subjects completed two gait …
-
Evidência científica e desenvolvimento tecnológico para neuropróteses motoras
… alternative assistive devices for patients with foot drop due to upper motor neuron lesion, such as stroke. Particularly because it allows orthotic effect and also training effect. The first one reflecting the direct improvement in tasks while using the MN and the second is related to a …
-
Evaluation of Gait Transitional Stability for Adults with Ankle-foot Impairments
… and over varying walking terrains. The ankle-foot deficiencies such as foot drop, Charcot-Marie-Tooth, eversion, and inversion are imitated with a uniform degree of impairments using healthy subjects and adjustable orthoses. The gait dynamic stabilities are assessed using frequency models of …
Page 1 of 2