Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 335 for “"Force Plate"”.

  1. ACUTE EFFECTS OF TRAINING LOADS ON FORCE PLATE METRICS

    … jump (CMJ) metrics, utilizing portable force plates to assess jump performance and inertial measurement units (IMUs) to quantify practice volume. Fourteen male athletes from McMaster University's basketball team participated, with data collected pre- and post-practice over a ten-week …

    mcmaster Repository record for ACUTE EFFECTS OF TRAINING LOADS ON FORCE PLATE METRICS (opens in a new tab)

  2. Evaluating and Developing Force Plate Practice for Monitoring Lower-Body Neuromuscular Function in Soccer

    … was to evaluate and identify a best practice for force plate assessments for monitoring lower body NMF in soccer. It was evident following a literature review and scoping review that there is a variety of options for force plate testing application, but no general consensus on a best practice …

    salford Repository record for Evaluating and Developing Force Plate Practice for Monitoring Lower-Body Neuromuscular Function in Soccer (opens in a new tab)

  3. Validation Of Mobile Devices In Arbitrary Locations Against Force Plate Standard For Balance Assessment

    … (COM) acceleration metrics against well regarded force plate center of pressure (COP) position standards for mobile device data acquisition systems, but most research is restricted to devices being close to the COM or strapped in a harness configuration. Through the use of rigid body kinematics …

    calpoly Repository record for Validation Of Mobile Devices In Arbitrary Locations Against Force Plate Standard For Balance Assessment (opens in a new tab)

  4. Modelling and Characterization of Force Plate Measurements on Subacute Post-Concussion Subjects Through Machine Learning

    Mild traumatic brain injuries (mTBI) are one of the leading causes of neurological disorders. Symptoms after a mTBI may include headache, dizziness, and balance issues, among others, with vestibular disorders observed in up to 80% of these patients. These symptoms generally resolve in the first few …

    gatech Repository record for Modelling and Characterization of Force Plate Measurements on Subacute Post-Concussion Subjects Through Machine Learning (opens in a new tab)

  5. The use of an embedded microcomputer-based force plate system for accurate sow lameness identification

    … data from each individual load cell in the force plate system in order to obtain accurate sow weight distributions on each leg to objectively detect lameness, and ii) to develop a lameness detection decision tree from the force plate output collected in a commercial setting. In the first …

    iastate Repository record for The use of an embedded microcomputer-based force plate system for accurate sow lameness identification (opens in a new tab)

  6. Standardized Application of Force Plate-based Measures of Standing Balance in the Sub-acute Stage of Stroke Recovery

    … rehabilitation and falls-prevention strategies. Force plate-based balance measures have previously been used to inform clinicians and researchers about balance impairments in the stroke population; however, little is known about their measurement properties, particularly in sub-acute stroke. The …

    toronto-retro Repository record for Standardized Application of Force Plate-based Measures of Standing Balance in the Sub-acute Stage of Stroke Recovery (opens in a new tab)

  7. Association of force plate and body-mounted inertial sensor measures for determination of hind limb lameness in horses

    … between inertial sensor and stationary force plate measures of hind limb lameness. 21 adult horses that were either sound or had mild hind limb lameness were utilized. Horses were instrumented with inertial sensors and evaluated for lameness with a stationary force plate while trotting …

    missouri Repository record for Association of force plate and body-mounted inertial sensor measures for determination of hind limb lameness in horses (opens in a new tab)

  8. Compensatory force plate responses to single or multiple limb lameness induction in horses using a hoof clamp technique.

    … measure the resultant changes in ground reaction forces. To compare the changes in ground reaction forces in both the limb(s) in which lameness was induced and in the sound limbs among a variety of individual and multiple-limb lameness scenarios to detect possible patterns in lameness and …

    umn Repository record for Compensatory force plate responses to single or multiple limb lameness induction in horses using a hoof clamp technique. (opens in a new tab)

  9. Case study : the comparison of WattBike cycle ergometer power metrics to common force-plate metrics for power profiling in professional soccer

    … ergometer power readings and commonly utilized Force-Plate markers of power in American Professional Soccer athletes. A total of 17 Major League Soccer Athletes were analyzed in this investigation throughout a professional season. Results displayed associations between Cycle Ergometer Peak Power …

    texas Repository record for Case study : the comparison of WattBike cycle ergometer power metrics to common force-plate metrics for power profiling in professional soccer (opens in a new tab)

  10. Balance Evaluation Using a Markerless Motion Capture System

    … characterize an individual’s balance ability. Force plate systems can be used to evaluate balance in a laboratory setting; however, their non-portability renders them difficult for use in the clinic and in the field. Markerless motion capture is an emerging technology which could bridge the gap …

    queens Repository record for Balance Evaluation Using a Markerless Motion Capture System (opens in a new tab)

  11. Validity and Reliability of the Balance Tracking System™ During Static Stance

    … collected on the BTrackS™ and a laboratory force plate to establish concurrent validity. A second testing session was administered 48 - 72 hours later to establish test-retest reliability. Independent variables were device (BTrackS™/force plate) and time (Time Point 1/Time Point 2). …

    gsu Repository record for Validity and Reliability of the Balance Tracking System™ During Static Stance (opens in a new tab)

  12. An evaluation of patients with anterior cruciate ligament reconstruction with an accelerometer and the step-up-and-over test

    … (SUAO). Presently, the test uses a force plate, an expensive device. Replacing the force plate with an accelerometer could make the SUAO test an inexpensive evaluation tool of ACLR patients. Therefore, this thesis had three objectives. First, to discover if an accelerometer is a …

    queens Repository record for An evaluation of patients with anterior cruciate ligament reconstruction with an accelerometer and the step-up-and-over test (opens in a new tab)

  13. The Effect of Backpack Carrying on the Gait of Young Children

    … The study utilized a Motion Analysis System. A force plate was fixed in the middle of the test site. Four high speed cameras were positioned on one side of the force plate. Each subject carried five different weights in sequence, and was required to walk naturally over the force plate. The …

    northern-iowa Repository record for The Effect of Backpack Carrying on the Gait of Young Children (opens in a new tab)

  14. Development and Validation of a Microcontroller-Based System for Force Distribution Measurement Under the Feet

    … of pressure measured by either a single or dual force-plate platform. Force distribution measurements can provide information on weight distribution, foot position and orientation, as well as foot-ground contact area. These measurements may be enhance our understanding of the postural control …

    marquette Repository record for Development and Validation of a Microcontroller-Based System for Force Distribution Measurement Under the Feet (opens in a new tab)

  15. Longitudinal tracking of physiological state with electromyographic signals.

    … performance by taking electromyography and force plate measurements before, during, and after a jump from a small platform. A LASSO regularization is performed to observe changes in relationship between electromyography features and force plate outcomes. SVM classifiers are employed to …

    louisville Repository record for Longitudinal tracking of physiological state with electromyographic signals. (opens in a new tab)

  16. INERTIAL MEASUREMENT UNITS AS PROXY MEASURES FOR KNEE KINETIC VARIABLES ASSOCIATED WITH ACL INJURY

    … to serve as reliable surrogates for traditional force plate measurements in assessing kinetic variables during ACLR rehabilitation.</p> <p>The study involved a healthy population to establish baseline measures unaffected by existing health conditions. Multilevel linear regression models were used …

    ut-knoxville Repository record for INERTIAL MEASUREMENT UNITS AS PROXY MEASURES FOR KNEE KINETIC VARIABLES ASSOCIATED WITH ACL INJURY (opens in a new tab)

  17. The effects of Risperidone on the vestibular system of healthy volunteers as assessed by dynamic computed posturography

    … by first assessing balance with a static force plate and eyes closed (Condition 2), and then assessed on a dynamic force plate with eyes closed (Condition 5). On average, Condition 2 scores were 24.46 points higher than Condition 5 scores (95% CI [20.973, 27.957]). A Pearson correlation …

    bu Repository record for The effects of Risperidone on the vestibular system of healthy volunteers as assessed by dynamic computed posturography (opens in a new tab)

  18. Body Sway and Aim Point Fluctuation in Rifle and Pistol Shooters

    … study examined the effects of quantisation of force plate data used to measure body sway and the relationship between this body sway, aim point fluctuation and performance in shooting. Quantisation error in and resolution of selected body sway parameters were calculated from force plate data …

    vu-aus Download PDF for Body Sway and Aim Point Fluctuation in Rifle and Pistol Shooters (opens in a new tab)

  19. The Validity of The VmaxPro during Countermovement Jump and Back Squat Performance

    … jump (CMJ) against a gold standard force plate. Squat variables assessed included mean concentric velocity (MCV), mean concentric power (MCP), depth, and duration while CMJ variables assessed included MCV, MCP, depth, duration, and jump height. Squat variables were assessed across 3 …

    usm Repository record for The Validity of The VmaxPro during Countermovement Jump and Back Squat Performance (opens in a new tab)

Page 1 of 17