Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 19 of 19 for “"Force Sensing Resistors"”.

  1. Force override rate controller for remote actuation

    … be more efficient if performed in unilateral force control mode. A six axis force-torque model was developed to determine the required number and positioning of sensors and using force sensing resistors, a prototype force-torque transducer was built for testing. Using a force error signal, …

    nps Repository record for Force override rate controller for remote actuation (opens in a new tab)

  2. FSR based force torque transducer design

    … the design, construction and calibration of two force-torque transducers for use in a force control override of a rate control system. Pre-loaded force sensing resistors were used in a computer model to determine the 6-umber and location of sensors necessary to resolve three forces and three …

    nps Repository record for FSR based force torque transducer design (opens in a new tab)

  3. Using Custom Integrated Force Sensing Mechanisms for Interaction Control in Rehabilitation Robots

    … interaction controllers on two custom integrated force sensing mechanisms and demonstrates their suitability for applications to the field of rehabilitation robotics. One condition in which interaction control is beneficial occurs when the robot's dynamics are significant and need to be …

    rice Repository record for Using Custom Integrated Force Sensing Mechanisms for Interaction Control in Rehabilitation Robots (opens in a new tab)

  4. Smart shoe gait analysis and diagnosis: designing and prototyping of hardware and software

    … them. The proposed method uses two A201 Force sensing resistors, accelerometer, and gyroscope to detect the gait and send diagnosed information of the possibility of the specified improper gaits via Bluetooth wireless communication system to the user's hand-held device or the desktop. The …

    iupui Repository record for Smart shoe gait analysis and diagnosis: designing and prototyping of hardware and software (opens in a new tab)

  5. REAL-TIME VISUALISATION AND ANALYSIS OF TACTILE INFORMATION USING FORCE SENSORS DURING ARTERIAL THREADING

    … of haptic feedback information generated using force-sensing resistors and game-engine technology for simulating and recording arterial threading. The experimental work was performed in a Virtual Learning Environment to evaluate the effectiveness of the force-sensing box trainer in simulating …

    liverpool-jm Repository record for REAL-TIME VISUALISATION AND ANALYSIS OF TACTILE INFORMATION USING FORCE SENSORS DURING ARTERIAL THREADING (opens in a new tab) Download PDF for REAL-TIME VISUALISATION AND ANALYSIS OF TACTILE INFORMATION USING FORCE SENSORS DURING ARTERIAL THREADING (opens in a new tab)

  6. Design and optimization of a three-fingered robot hand

    … presses the piano key, it should apply 1N force to play a note. Force Sensing Resistors at each finger tip, as a control method, are introduced to the system to accurately measure the amount of applied force from the finger tip on the key and increase the angle of rotation of the motor if …

    uoit Repository record for Design and optimization of a three-fingered robot hand (opens in a new tab)

  7. Impacts to hockey skates evaluated via a novel surrogate

    … allow for dynamic impact data collection using force sensing resistors (FSRs), which were placed on the surrogate HT at six locations known to be vulnerable to puck impact injuries. Various hockey skates with the surrogate inserted were subjected to experimental puck blows at the relevant …

    mcmaster Repository record for Impacts to hockey skates evaluated via a novel surrogate (opens in a new tab)

  8. Evaluation of periodontal scaling task and development of force-endurance models for simulated scaling task

    Force exertion is critical in grasping and holding activities at sub-maximal levels. Exertion misjudgments lead to musculoskeletal disorders (MSDs) impairing performance and productivity. Published literatures on grasping have addressed the force balance and endurance issues for non-prehensile …

    nebraska Repository record for Evaluation of periodontal scaling task and development of force-endurance models for simulated scaling task (opens in a new tab)

  9. An evaluation of hand pressure distribution and forearm flexor muscle contribution for a power grasp on cylindrical handles

    … of the forearm flexor muscles to the total grasp force in power grip were estimated. Twenty-three Force Sensing Resistors (FSR) were placed on the palmar surface of the hand. Five cylindrical handles with cross-sectional diameters of 2.2, 2.8, 3.5, 4.2, and 5.05 cm were tested. Each subject …

    nebraska Repository record for An evaluation of hand pressure distribution and forearm flexor muscle contribution for a power grasp on cylindrical handles (opens in a new tab)

  10. Design of an Ankle Exoskeleton Employing Dual Action Plantarflexion Assistance and Gait Progression Detection

    … The prototype additionally features an array of force sensing resistors for tracking gait progression and exploring potential user-based control strategies for synchronizing the exoskeleton actuator with a wearer's gait. Performance analysis for this prototype was conducted with the goal of …

    vt Repository record for Design of an Ankle Exoskeleton Employing Dual Action Plantarflexion Assistance and Gait Progression Detection (opens in a new tab)

  11. Development and Assessment of a Coupling Force Measurement System Applied to Stationary and Vibrating Tool Handles

    … affected by the hand-handle interface coupling forces, handle geometry and gripping method apart. Assessment of the HTV exposure currently does not incorporate the impact of coupling forces exerted at the hand-handle interface, mostly due to lack of reliable measurement methods for hand-handle …

    concordia Download PDF for Development and Assessment of a Coupling Force Measurement System Applied to Stationary and Vibrating Tool Handles (opens in a new tab)

  12. Pressure distribution at the stump socket interface in trans-tibial amputees

    … bar forwards and at the same time measuring the forces along three orthogonal directions. However the design of this transducer restricted its use to only one subject. The present study aimed to investigate more than one subject, and so a Patellar tendon bar (Mark-II) transducer was developed, …

    strathclyde Repository record for Pressure distribution at the stump socket interface in trans-tibial amputees (opens in a new tab)

  13. Fully Integrated Slippage Detection System for Lower Limb Amputees

    … with Interlink 406 flexible piezoresistive force-sensing resistors (FSRs). The sock, worn directly on the residual limb, continuously measures pressure at the limb-socket interface. Sensor data from six FSRs is sampled at approximately 240 Hz and transmitted via Bluetooth to an iOS mobile …

    calpoly Repository record for Fully Integrated Slippage Detection System for Lower Limb Amputees (opens in a new tab)

  14. Analysis And Classification Of Motor Dysfunctions In Gait By Using Wearable Sensors

    … use Inertial Measurement Units (IMU) and Force Sensing Resistors (FSR). Furthermore, a method to synchronize these devices is presented. This ensures higher data quality and allows new approaches to analysis. To ensure that the devices work energy-effciently, activity recognition based on …

    ulpgc Repository record for Analysis And Classification Of Motor Dysfunctions In Gait By Using Wearable Sensors (opens in a new tab)

  15. Force sensing glove for quantification of joint torques during stretching after spinal cord injury in the rat model.

    … individuals. A glove device utilizing force sensing resistors (FSRs) was developed to gauge joint torques. Coupled with a custom National Instruments’ LabVIEW program, the device was able to accurately measure forces, and eventually torques, applied during stretching. This study sought …

    louisville Repository record for Force sensing glove for quantification of joint torques during stretching after spinal cord injury in the rat model. (opens in a new tab)

  16. Quantitative analysis of oral phase dysphagia

    … methods are proposed. A computer-aided tongue force measurement system has been developed that is capable of quantifying individual tongue strength and coordination. This strain gauge-based transducer system measures upward and lateral tongue thrust levels during a "non-swallowing" test …

    ubc Repository record for Quantitative analysis of oral phase dysphagia (opens in a new tab) Download PDF for Quantitative analysis of oral phase dysphagia (opens in a new tab)

  17. Human Spacesuit Interaction during EVA of the Legs Using a Force Sensing System

    … legs, including the knee and ankle area, using a force sensing system made up of force sensing resistor (FSR) sensors. The first aim of this project was to conduct a review on previous studies to uncover any trends that were observed in terms of specific locations where injury was observed or …

    usf Repository record for Human Spacesuit Interaction during EVA of the Legs Using a Force Sensing System (opens in a new tab)

  18. CONTACT PRESSURE MEASUREMENT

    The knowledge of the correct clamping force in a bolted joint is important in the prevention of leakage and in extending the life span of the joint. One of the methods to tighten the joints to the correct clamping force would be to use torque wrenches but this and other techniques do not indicate …

    nus Repository record for CONTACT PRESSURE MEASUREMENT (opens in a new tab) Download file for CONTACT PRESSURE MEASUREMENT (opens in a new tab)

  19. Estudo e desenvolvimento de sistema baseado em sensores de pressão aplicados à ortodontia

    Este trabalho tem por objetivo o estudo e o desenvolvimento de uma solução de engenharia para o mapeamento e caracterização da oclusão dentária, não somente no âmbito de sua distribuição ao longo da arcada, mas também através da mensuração da intensidade de pressão nos pontos de contato oclusal …

    brazil-ufrgs Repository record for Estudo e desenvolvimento de sistema baseado em sensores de pressão aplicados à ortodontia (opens in a new tab)