Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"Forward viewing"”.

  1. Forward-Viewing Ultrasound Guidance of a Robotically-Steered Guidewire for Peripheral Interventions

    … by interventionalists. In the second phase, a forward-viewing, single-element transducer was designed, fabricated, and characterized. The transducer was integrated with a robotic guidewire, and an image formation strategy was developed with synthetic aperture beamforming from the expanded …

    gatech Repository record for Forward-Viewing Ultrasound Guidance of a Robotically-Steered Guidewire for Peripheral Interventions (opens in a new tab)

  2. Forward-viewing intravascular ultrasound-derived wall shear stress for PCI optimization: phantom and CFD studies

    … after PCI. In order to determine the ability of forward-viewing intravascular ultrasound (FV-IVUS) to assess stent placement by imaging WSS, a high frequency commercial linear array was placed in a forward-viewing position and used to acquire images in 9 different scenarios in vessel-mimicking …

    gatech Repository record for Forward-viewing intravascular ultrasound-derived wall shear stress for PCI optimization: phantom and CFD studies (opens in a new tab)

  3. Development of forward-viewing high-frequency ultrasound techniques for velocity and wall shear stress estimation in coronary arteries

    … depths. For this reason, a catheter-based forward-viewing intravascular ultrasound imaging system is being developed to estimate real-time 3D velocity fields and WSS distributions in coronary arteries. In the subsequent chapters, the development of forward-viewing, high-frequency ultrasound …

    gatech Repository record for Development of forward-viewing high-frequency ultrasound techniques for velocity and wall shear stress estimation in coronary arteries (opens in a new tab)

  4. Dual-View Catadioptric Imaging System Design for Endoscopy

    … tissue autofluorescence is weak and conventional forward viewing endoscopes are inefficient in light collection from objects of interest located on the GI tract wall. This thesis work presents the design and optimization of a catadioptric endoscope objective lens that is capable of acquiring …

    mcmaster Repository record for Dual-View Catadioptric Imaging System Design for Endoscopy (opens in a new tab)

  5. Dual Modality Optical Coherence Tomography and Multispectral Fluorescence Imaging for Ovarian Cancer Detection

    … lens design for a scanning fiber endoscope with forward-viewing navigation and side-viewing OCT. A piezo tube is used to scan an optical fiber providing both the navigation channel’s illumination and OCT imaging. The design spatially separates the forward-viewing illumination from the OCT. As the …

    arizona-thes Repository record for Dual Modality Optical Coherence Tomography and Multispectral Fluorescence Imaging for Ovarian Cancer Detection (opens in a new tab)

  6. Array design and development for steerable robotic guidewire

    … A steerable robotic guidewire with integrated forward-viewing imaging capabilities would allow the guidewire to navigate through tortuous vasculature and facilitate crossing CTOs in revascularization procedures that currently fail due to inability to route the guidewire. The robotic steering …

    gatech Repository record for Array design and development for steerable robotic guidewire (opens in a new tab)

  7. Towards the development of an all-optical, non-contact, photon absorption remote sensing (PARS) endomicroscope for blood vasculature imaging

    … design, development, and validation of the first forward-viewing, non-contact, all-optical Photon Absorption Remote Sensing (PARS) endomicroscope for in vivo vascular imaging. The proposed system is designed to leverage the endogenous optical absorption of hemoglobin to achieve high-resolution …

    waterloo Repository record for Towards the development of an all-optical, non-contact, photon absorption remote sensing (PARS) endomicroscope for blood vasculature imaging (opens in a new tab)

  8. The Potential of Optical Coherence Tomography for Intravascular Imaging of Chronic Total Occlusions

    … As a potential intravascular imaging set-up, a forward-viewing OCT catheter was built. This catheter uses a novel scanning mechanism that combines high voltage and a dissipative polymer to achieve fast compact actuation. Doppler OCT results are presented using this catheter to image flow in the …

    toronto-retro Repository record for The Potential of Optical Coherence Tomography for Intravascular Imaging of Chronic Total Occlusions (opens in a new tab)

  9. Design, Modeling, and Image-Based Control of Robotically Steerable Systems for Endovascular Interventions

    … validation includes the integration of a forward-viewing ultrasound transducer into a tendon-driven guidewire for real-time imaging in in vivo scenarios. Finally, a novel, dexterous guidewire robot is developed and navigated through neurovascular anatomies via radial access in phantom …

    gatech Repository record for Design, Modeling, and Image-Based Control of Robotically Steerable Systems for Endovascular Interventions (opens in a new tab)

  10. Design, Modeling, and Image-Based Control of Robotically Steerable Systems for Endovascular Interventions

    … validation includes the integration of a forward-viewing ultrasound transducer into a tendon-driven guidewire for real-time imaging in in vivo scenarios. Finally, a novel, dexterous guidewire robot is developed and navigated through neurovascular anatomies via radial access in phantom …

    gatech Repository record for Design, Modeling, and Image-Based Control of Robotically Steerable Systems for Endovascular Interventions (opens in a new tab)

  11. Ultrasound Transducer Arrays for Risk Stratification in Coronary Artery Disease

    … imaging during PCI. However, current side-viewing IVUS does provide imaging of physiology and must cross the lesion in order to image it. Alternatively, forward-viewing IVUS could be used to evaluate lesion structure, composition, and hemodynamics within the procedure without crossing the …

    gatech Repository record for Ultrasound Transducer Arrays for Risk Stratification in Coronary Artery Disease (opens in a new tab)

  12. Optimization of multimodal OCT for early cancer detection and diagnosis

    … lesions. Lastly, I present a design for a forward-viewing fiber scanning high resolution OCT probe for in vivo cervical imaging in the clinic. To enable high resolution imaging but allow for sufficient depth penetration into tissue, OCT systems use near-infrared light ~1000 nm in …

    ubc Repository record for Optimization of multimodal OCT for early cancer detection and diagnosis (opens in a new tab) Download PDF for Optimization of multimodal OCT for early cancer detection and diagnosis (opens in a new tab)

  13. Multimodal Optical Imaging for Tissue Characterization and Disease Diagnosis

    … study concludes with the design for a multimodal forward-viewing esophageal endoscope using optical coherence tomography and autofluorescence imaging. The design implements a piezo-scanning fiber to deliver the light, and spatially separates the OCT and fluorescence return signal. The design …

    arizona-thes Repository record for Multimodal Optical Imaging for Tissue Characterization and Disease Diagnosis (opens in a new tab)

  14. Development of Multi-modal Optical Coherence Tomography Imaging Systems and Probes

    … in endomicroscopic applications by developing forward and side-viewing probes. Both classes of probes were designed with cost-efficient scanners while maintaining high performance. The side-viewing probes use a 6 mm diameter micro stepper motor and a custom Gradient Index (GRIN) achieving 26 μm …

    houston Repository record for Development of Multi-modal Optical Coherence Tomography Imaging Systems and Probes (opens in a new tab) Embargoed until 2026-12-01

  15. Optical Coherence Tomography through Fibre Bundles by Angled Divergent Illumination

    … of research towards the goal of achieving a forward-viewing Endoscopic OCT (E-OCT) system suitable for clinical enrolment. Several avenues for further research are suggested, that if perused may lead to clinical application of the new method.

    kent Download PDF for Optical Coherence Tomography through Fibre Bundles by Angled Divergent Illumination (opens in a new tab)

  16. The fluid mechanics of convection and diffusion in medical devices for visualization in arteries and clearing of urea in hemodialysis. Analysis, design, and optimization via CFD and experimental analysis

    … an endovascular catheter that combines imaging forward-viewing element with saline flushing lumens. A novel design and control technique is developed that provides the method to regulate the pressure in a blocked artery during saline flushing, so only small deviations from physiological pressure …

    washington Repository record for The fluid mechanics of convection and diffusion in medical devices for visualization in arteries and clearing of urea in hemodialysis. Analysis, design, and optimization via CFD and experimental analysis (opens in a new tab)