Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 15 of 15 for “"Fourier number"”.

  1. Solidification Cracking in Binary Al-Cu Alloys Additively Manufactured through Laser Powder Bed Fusion

    … in the theoretical model when a back-diffusion Fourier number was incorporated into the Scheil equation to account for solid-state diffusion during solidification. This shift can also be observed by increasing the partition coefficient above its equilibrium value, which is expected during rapid …

    ucf Repository record for Solidification Cracking in Binary Al-Cu Alloys Additively Manufactured through Laser Powder Bed Fusion (opens in a new tab)

  2. Collapse of steam bubbles in subcooled water

    … used. The data indicate a decrease in collapse Fourier number with increase in either Jakob number or steam flow rate, or with a decrease in pressure, while change in orifice diameter does not have a significant effect on collapse Fourier number. Average values of heat transfer coefficient …

    strathclyde Repository record for Collapse of steam bubbles in subcooled water (opens in a new tab)

  3. Measurements and analytical modeling of heat transfer in flowing granular media

    … predictions from the model ( in terms of Nusselt number versus Fourier number), the maximum difference observed was 39 percent, over a Fourier number range from 0.001 to 20. The average difference observed was estimated to be about 12.6 percent.</p>

    utk-theses Repository record for Measurements and analytical modeling of heat transfer in flowing granular media (opens in a new tab)

  4. Scale Modeling of Tests with Combined Thermo-Structural Loading

    … incorporates uniform geometric scaling, Fourier number time scaling, and furnace boundary condition matching. The scaling laws were experimentally validated with fire exposure tests on gypsum wallboard samples at three scales (full-scale, 1/2-scale, and 1/6-scale). Next, these scaling …

    vt Repository record for Scale Modeling of Tests with Combined Thermo-Structural Loading (opens in a new tab)

  5. TRANSIENT TEMPERATURE MEASUREMENTS OF COMBUSTOR WALLS ENCLOSING A 2-D MODEL COAXIAL INJECTOR

    … heat transfer analysis applicable for low Biot number and low Fourier number conditions. Infrared thermometry technique was applied to obtain outer wall temperature distribution at three different wall thicknesses, and these measurements were combined with the transient analysis to calibrate the …

    maryland Repository record for TRANSIENT TEMPERATURE MEASUREMENTS OF COMBUSTOR WALLS ENCLOSING A 2-D MODEL COAXIAL INJECTOR (opens in a new tab)

  6. A New Fully Implicit in Time Two-Dimensional Inverse Heat Conduction Method

    … of the inverse solution. However, the nodal Fourier number was found to have no effect on accuracy. Further investigation into the effect of the Fourier number on the inverse solution led to the discovery of a precisely defined stability criterion, which is presented for the one-dimensional …

    ut-knoxville Repository record for A New Fully Implicit in Time Two-Dimensional Inverse Heat Conduction Method (opens in a new tab)

  7. Thermomechanics of helical strands and helical-fiber-reinforced rods

    … waves in a helical strand are solved. With Fourier-type heat conduction, the thermelastic wave solutions are governed by four non-dimensional parameters: two thermoelastic coupling constants (in the longitudinal and torsional directions), a chirality parameter, and the Fourier number. The …

    uiuc Repository record for Thermomechanics of helical strands and helical-fiber-reinforced rods (opens in a new tab)

  8. Thermal Modeling of Phase Change Material (PCM) with Nanoparticles and Porous Matrix for Melting and Freezing

    … different non-dimensional parameters such as Fourier number, Stefan number, porosity and volume fraction. The model is compared with the exact solution of existing literature for equivalent thermophysical properties of NanoPCM with porous medium and found good agreement between the exact …

    guelph Repository record for Thermal Modeling of Phase Change Material (PCM) with Nanoparticles and Porous Matrix for Melting and Freezing (opens in a new tab)

  9. Bench Scale Characterization of Joints and Coatings

    … boards, which integrated geometric scaling, Fourier number time scaling, and furnace boundary condition matching. Intumescent coating presents a particular challenge in scaling in that it expands when exposed to fire conditions. To account for this expansion, we identified a relationship …

    vt Repository record for Bench Scale Characterization of Joints and Coatings (opens in a new tab)

  10. Experimental & Numerical Evaluation of Borehole Thermal Energy Storage Fields

    … to minimize the effect of thermal interaction, a Fourier number of less than 0.06 is required. The investigation then focuses on thermal performance of a borehole thermal energy storage field (BTES). This study provides an extensive experimental dataset of the operation of a BTES supplemented with …

    mcmaster Repository record for Experimental & Numerical Evaluation of Borehole Thermal Energy Storage Fields (opens in a new tab)

  11. Droplet Impact, Infiltration, and Boiling in Pores and Porous Media

    … steam generation increases with a decreasing Fourier number and that steam generators should be designed with a Fo

    toronto-retro Repository record for Droplet Impact, Infiltration, and Boiling in Pores and Porous Media (opens in a new tab)

  12. Parametric study of the dermal temperature profiles during cryolipolysis

    … two parameters in the Pennes equation: the Fourier number and a blood perfusion parameter. This scaled equation has the form of a 1D transient fin equation. Green's function solutions were used to model the temperature profile. The model revealed that the 30 min and 60 min treatment …

    msu Repository record for Parametric study of the dermal temperature profiles during cryolipolysis (opens in a new tab)

  13. Accuracy Improvement for Measurement of Gas Diffusivity through Thin Porous Media

    … of approximately 20% error. The equivalent Fourier number, Fo_eq, based on the equivalent diffusivity, D_eq, was proposed as an approximate expression for the degree to which the concentration gradient in the test cell has evolved. It was found that the error has nearly a linear relationship …

    waterloo Repository record for Accuracy Improvement for Measurement of Gas Diffusivity through Thin Porous Media (opens in a new tab)

  14. AI-orchestrated physics-informed modelling and predictive control with applications in energy-intensive manufacturing and battery management

    … module embedding the temperature-dependent Fourier number, and knowledge distillation with transfer learning. These components allow the model to use physical structure both during training and when generalising to previously unseen operating conditions. Validation on a pilot-scale …

    whiterose Download PDF for AI-orchestrated physics-informed modelling and predictive control with applications in energy-intensive manufacturing and battery management (opens in a new tab)