Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 206 for “"Fourier transform spectroscopy"”.
-
Fourier Transform Spectroscopy of Selected Transient Species
… detected in emission using a Bruker IFS 120 HR Fourier transform spectrometer. Combined-isotopomer Dunham-type molecular constants have been derived for GeO using the DSParFit computer program. Analysis shows that the Born-Oppenheimer approximation is valid, as expected, for a molecule …
-
Far infrared fourier transform spectroscopy using ring interferometer
… Moller, was built and set up for far-infrared Fourier transform spectroscopy. The ring interferometer has ten circular mirrors with the same area. By applying Fraunhofer diffraction theory, the calculation shows that the ring interferometer will have large diffraction angle range compared with …
-
Fourier transform spectroscopy of the Orion molecular cloud
… presents the first results obtained using a Fourier Transform Spectrometer (FTS) at the James Clerk Maxwell Telescope to study, simultaneously, the continuum and line components of emission on the OMC.
-
Laser and Fourier transform spectroscopy of gas phase molecules.
Laser and Fourier transform spectroscopy were used to study a variety of gas phase molecules. A series of calcium and strontium monoalkoxides, CaOR and SrOR [R=H, CH₃, CH₂CH₃, CH(CH₃)₂, CH₂CH₂CH₃, CH₂(CH₂)₂CH₃, CH₂(CH₃)CH₂CH₃ and C(CH₃)₃] was studied by laser induced fluorescence and laser …
-
Quantitative matrix isolation Fourier transform spectroscopy of polycylic aromatic hydrocarbons
<p>The utility of matrix isolation Fourier transform infrared spectroscopy (MI FTIR) for the qualitative and quantitative analysis of isomeric polycyclic aromatic hydrocarbons (PAH's) was demonstrated. MI FTIR spectra of sixteen methylated and ten hydrogenated PAH's were obtained.</p><p>In order to …
-
Mid-infrared frequency comb fourier transform spectroscopy for chemical analysis
RU Radboud Universiteit, 28 oktober 2016
-
DEVELOPMENT OF A MEMS LAMELLAR GRATING SPECTROMETER FOR FOURIER TRANSFORM SPECTROSCOPY
… and characterization of a lamellar grating-based Fourier Transform micro-spectrometer. The proposed device has a compact structure with low machining cost and can be potentially applied to determine the presence and compositions of chemicals through their signature spectra. It is realized through …
-
Laser spectroscopy of metal-containing molecules and Fourier transform spectroscopy of small molecules.
… BH and BD, were recorded using a high resolution Fourier transform spectrometer. These compounds were made in a B₄C/Cu composite-wall hollow cathode lamp. The B⁴Σ⁻-X⁴Σ⁻ transition of BC was observed near 17900 cm⁻¹. The ground state internuclear separation was found to be 1.488A. The rotational …
-
Time-resolved mid-infrared dual-comb and Fourier transform spectroscopy for plasma diagnostics
… research. Broadband, time-resolved absorption spectroscopy offers the possibility to simultaneously monitor the time-dependent parameters of chemical reactions, such as concentrations of intermediate/final products, free radicals, and ions, as well as branching ratios, reaction rate …
-
Far-Infrared Fourier Transform Spectroscopy of NTD Ge and GeᵪSi₍₁_ᵪ₎/Si Heterostructures
<p>Far-infrared Fourier transform spectroscopy is used to investigate the excited states of impurities in semiconductors. Two different research projects are presented. The first involves an investigation of the far-infrared absorption of compensated p-type Ge at a temperature of 3 K. The …
-
Astronomical submillimetre Fourier transform spectroscopy from the Herschel Space Observatory and the JCMT
Fourier transform spectroscopy (FTS) is one of the premier ways to collect source information through emitted radiation. It is so named because the principal measurement technique involves the analysis of spectra determined from the Fourier transform of a time-domain interference pattern. Given …
-
Coherent Response of Two Dimensional Electron Gas probed by Two Dimensional Fourier Transform Spectroscopy
… several tens of picoseconds. Nonlinear optical spectroscopy techniques, such as pump-probe, transient four wave mixing (TFWM), etc., are very common to study the carrier dynamics in various material systems. In time domain, the transient FWM uses several ultrashort pulses separated by time …
-
Imaging Fourier transform spectroscopy from a space based platform : the Herschel/SPIRE Fourier transform spectrometer
… on SPIRE consists of a Mach-Zehnder (MZ)-Fourier transform spectrometer (FTS) coupled with bolometric detector arrays to form an imaging FTS (IFTS). This thesis presents experiments conducted to verify the performance of an IFTS system from a space based platform, i.e. the use of the SPIRE …
-
Dynamical Architecture of Transiting Planets with Outer Companions and Fourier Transform Spectroscopy for Directly Imaged Exoplanets
… Second, I explored the potential of an imaging Fourier transform spectrograph (iFTS) to obtain atmospheric spectra from Earth-like planets. The Decadal Survey on Astronomy and Astrophysics 2020 has recommended a decade-long effort to mature technologies for a space-based direct imaging …
-
Pulsed molecular beam cavity microwave Fourier transform spectroscopy of some fundamental van der Waals dimers and trimers
… using a pulsed molecular beam cavity microwave Fourier transform spectrometer. Ar-Cl₂ has been found to have a T-shaped geometry dominated by pairwise additive forces, in contrast to the previously studied linear complex Ar-ClF. An effective van der Waals bond distance has been obtained, as well …
-
Fourier-transform spectroscopy of the triply-ionised lanthanides in lithium yttrium fluoride (LiYF4) and barium yttrium fluoride (BaY2F8)
… none to our knowledge have been measured by Fouriertransform spectroscopy with its extremely high resolution and absolute frequency accuracy. Previous studies were performed using diffraction grating spectrometers, where signal-to-noise considerations limit resolution and frequency …
-
Determination of the Internal Rotational Energy of Gaseous 1,2-Dichloroethane in an Argon Matrix Using Fourier Transform Spectroscopy
A sample cell and delivery system for rapid matrix isolation of gas mixtures at constant gas temperature was designed and evaluated. The rotational energy differences of 1,2-dichlorosthane and of its deuterium compound wars then determined to test this technique. The rotational energy barriers …
Page 1 of 11