Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 49 for “"Fracture load"”.

  1. Fracture load of CAD/CAM feldspathic crowns influenced by abutment material

    … a material that resembles human dentin in fracture load tests. Sixteen human teeth were scanned with an intraoral scanner to obtain copies of the original crown morphology and were then prepared for crowns. Replica dies of the prepared teeth including the root morphology were fabricated …

    zurich Restricted access

  2. Strain-rate Dependent Fracture Load Prediction of Lead-free Solder Joints

    … initiation, Jci, has been shown to govern the fracture of short solder joints. The present work measured Jci for 2 mm long SAC305 solder joints as a function of the strain rate and phase angle using DCB specimens. A drop tester was designed and built to perform the experiments at higher strain …

    toronto-retro Repository record for Strain-rate Dependent Fracture Load Prediction of Lead-free Solder Joints (opens in a new tab)

  3. Fracture Load of Cantilever Implant-Supported Zirconia Fixed Partial Dentures: An In Vitro Study

    … The purpose of this study is to evaluate the fracture strength of cantilevered implant supported fixed partial dentures (cFPDs) fabricated using two distinct types of zirconia: conventional high-strength monochromatic composition (3Y-TZP - tetragonal zirconia polycrystal) and high-translucency …

    buffalo Repository record for Fracture Load of Cantilever Implant-Supported Zirconia Fixed Partial Dentures: An In Vitro Study (opens in a new tab)

  4. Reduced fracture load of dental implants after implantoplasty with different instrumentation sequences. An in vitro study

    … implants after implantoplasty and thermocyclic loading, the residual thickness of the instrumented areas and neighbouring tooth injury due to implantoplasty. Materials and Methods Using a phantom head simulator and maxillary model implants were subjected to an implantoplasty procedure. Thirty …

    zurich Restricted access

  5. Fracture load of machined Y-TZP zirconia fixed-dental-prosthesis frameworks, fabricated with different CAD/CAM systems

    … type of the fabrication has an influence on the fracture load. The null-hypothesis was that no influence on the fracture load of the frameworks of zirconia fixed-partial-denture frameworks should be found. Methods: Two control and nine test groups allowed us to investigate the difference between …

    zurich Restricted access

  6. The significance of embrasure design on the fracture load of fixed denture prosthesis: an in vitro study

    … by measuring their differential effect on load at failure of provisional fixed partial dentures (FPDs) fabricated of five commercially available polymer-based restorative materials. METHODS: Five provisional C&B materials were selected to fabricate FPDs with two different embrasure designs: …

    bu Repository record for The significance of embrasure design on the fracture load of fixed denture prosthesis: an in vitro study (opens in a new tab)

  7. Effect of Different Supporting Die Materials and Crown Thicknesses on the Fracture Load of Monolithic 3Y-TZP Zirconia and Lithium Disilicate Crowns

    … geometry (i.e crowns) under clinically relevant loading conditions. One advantage of performing the so-called crown fracture test is that the material may benefit from its ability to be strengthened by its bond to a tooth-mimicking die. When performing a crown fracture test, the ideal die …

    uab Repository record for Effect of Different Supporting Die Materials and Crown Thicknesses on the Fracture Load of Monolithic 3Y-TZP Zirconia and Lithium Disilicate Crowns (opens in a new tab)

  8. Comparison of Crown Fracture and Wear Resistence of Resin 3D Printed Permanent Crown and Other Restorative Materials

    … Comparing the mechanical properties such as fracture load (N) and wear resistance for 3D printing permanent restorations resins would represent a very good reference to consider future clinical decisions. Purpose: To investigate the fracture load (N) and wear resistance of the resins for 3D …

    uab Repository record for Comparison of Crown Fracture and Wear Resistence of Resin 3D Printed Permanent Crown and Other Restorative Materials (opens in a new tab)

  9. The Difference in Fracture Strength of Translucent Zirconia (5Y-Z) Using Different Cements and Surface Treatments

    … Purpose: To investigate the difference in fracture strength of translucent zirconia (5Y-Z) using different crown thickness, different cements under different surface treatment conditions. Materials and Methods: The experimental design consisted of five groups of 30 specimens each. Two …

    uab Repository record for The Difference in Fracture Strength of Translucent Zirconia (5Y-Z) Using Different Cements and Surface Treatments (opens in a new tab)

  10. Bond strength between veneer porcelains and CAD/CAM ceramic to CP titanium and evaluation of fracture load and effect of aging on low fusing porcelain fired over CP TI and CAD / CAM materials cemented onto CP TI

    OBJECTIVES: The aim of this study was to evaluate the bond strength of three different veneering porcelains fired over CP Titanium and a CAD/CAM ceramic cemented to CP Titanium. METHODS: Sixty-four bars of CP Titanium grade II (25±1x 3±0.5x 0.5±0.05 mm) were divided randomly into four groups: Group …

    bu Repository record for Bond strength between veneer porcelains and CAD/CAM ceramic to CP titanium and evaluation of fracture load and effect of aging on low fusing porcelain fired over CP TI and CAD / CAM materials cemented onto CP TI (opens in a new tab)

  11. Fatigue behaviour and failure modes of monolithic CAD/CAM hybrid-ceramic and all-ceramic posterior crown restorations

    … molar crown model. The correlation between fracture load, cement thickness, crack length, and contact area size was also analysed. Resin-based composite dies (n = 54) were used as abutments for three different monolithic CAD/CAM fabricated crowns subdivided to one test group (experimental …

    freiburg-diss Repository record for Fatigue behaviour and failure modes of monolithic CAD/CAM hybrid-ceramic and all-ceramic posterior crown restorations (opens in a new tab)

  12. Αξιολόγηση δύο αμιγώς ολοκεραμικών διαβλεννογονίων εμφυτευματικών τμημάτων εσωτερικής ένωσης: ITI Straumann – Xive, Friadent

    … ones and with higher resolution. The preload of two dental abutments, one of each system, have been measured five times for each specimen. Each measurement had been recorded with a digital torquing machine. Between torquing and untorquing there was an interval of two minutes. Ten dental …

    greece Repository record for Αξιολόγηση δύο αμιγώς ολοκεραμικών διαβλεννογονίων εμφυτευματικών τμημάτων εσωτερικής ένωσης: ITI Straumann – Xive, Friadent (opens in a new tab)

  13. Endodontic Access Through Zirconia Crowns: A Comparative Evaluation of 3D Guided Versus Free-handed Techniques

    … access achieved. Access time was recorded. For fracture load testing, specimens were mounted in acrylic resin and loaded using a universal testing machine with a 4-mm stainless steel indenter at 1.25 mm/min until failure. Fracture load was recorded in Newtons (N). Normality was assessed using …

    vcu Repository record for Endodontic Access Through Zirconia Crowns: A Comparative Evaluation of 3D Guided Versus Free-handed Techniques (opens in a new tab)

  14. Factors Affecting the Fracture Strength and Fatigue Resistance of Molar Crowns Produced Using a Zirconia-based System

    … core thickness and veneering technique on fracture mode and strength of zirconia-porcelain specimens of simple geometry. Results indicated that all three variables significantly affected mean fracture load, while only two (total thickness and core thickness) affected fracture mode. The …

    toronto-retro Repository record for Factors Affecting the Fracture Strength and Fatigue Resistance of Molar Crowns Produced Using a Zirconia-based System (opens in a new tab)

  15. An Investigation on the Influence of Stumbling Loads on Femoral Fracture Risk, Using a Novel Gradient Enhanced Quasi-Brittle Finite Element Model

    … these events contribute to osteoporotic hip fracture risk. We hypothesized that stumbling may increase risk, either causing fracture directly, or damaging the femur leaving it susceptible to future loading. This hypothesis can be tested in-silico, but previously published finite element (FE) …

    carleton Repository record for An Investigation on the Influence of Stumbling Loads on Femoral Fracture Risk, Using a Novel Gradient Enhanced Quasi-Brittle Finite Element Model (opens in a new tab)

  16. Comprehensive Investigation of Quasibrittle Fracture of IM7/977-3 Laminates via Size Effect Analysis

    … investigates the non-linear size effect of fracture of IM7/977-3 laminates with different sizes in multiple modes including the matrix-dominated Mode I intralaminar fracture, the fiber-dominated Mode I intralaminar fracture, the Mode I interlaminar fracture, and the Mode II interlaminar …

    washington Repository record for Comprehensive Investigation of Quasibrittle Fracture of IM7/977-3 Laminates via Size Effect Analysis (opens in a new tab)

  17. Comparison of Mechanical Properties of Latex and Latex-Free Elastics

    … sets of tests were conducted. In the first set, fracture load and extension at fracture were measured using an Instron Universal testing machine. In the second set of tests, the maximum load, 2 minute load, load relaxation and relaxation energy were measured with the Instron as well. Specimens …

    marquette Repository record for Comparison of Mechanical Properties of Latex and Latex-Free Elastics (opens in a new tab)

  18. Fracture of Underfilled and Edge-Bonded BGA-PCB Assemblies: Effects of Joint Geometry, Strain Rate and Stiffness

    … The focus of the present research was the fracture performance of component-solder-PCB assemblies with and without underfill adhesives under bending loading conditions. Fracture tests of copperâ solderâ copper double-cantilever-beam (DCB) specimens with a single continuous solder layer …

    toronto-retro Repository record for Fracture of Underfilled and Edge-Bonded BGA-PCB Assemblies: Effects of Joint Geometry, Strain Rate and Stiffness (opens in a new tab)

  19. Internal Redundancy of Mechanically-Fastened Steel Built-Up Axially-Loaded Members

    … if mechanically-fastened steel built-up axially-loaded tension members are resistant to complete cross-sectional fracture when a single component suddenly fractures and if so, to develop simplified methods of analysis for post-fracture load redistribution behavior for calculation of remaining …

    purdue-thes Repository record for Internal Redundancy of Mechanically-Fastened Steel Built-Up Axially-Loaded Members (opens in a new tab)

Page 1 of 3