Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 6 of 6 for “"Fragment Mass Analyzer"”
-
Nuclear Structure of 26Si and 32Cl for Astrophysics
… were detected by Gammasphere, and the Argonne Fragment Mass Analyzer (FMA) was used to separate heavy ions. We built the level scheme for 32Cl from gamma-gamma coincidences, determining energies for 6 states, including 2 levels at Ex = 1738.1 (6) and 2130.5 (10) keV that correspond to the most …
-
Investigation of Shell Model States in Exotic Odd-A Sb Isotopes
… resonance ionization laser ion source. Following mass separation of the Sn nuclei, it was possible to collect g-ray singles and g-g coincidence data as a function of time for the decays of 134Sn and 135Sn. From these data, the position of the 7- b-decaying isomer in 134Sb has been established at …
-
Alpha and Gamma-ray Spectroscopic Studies of Au, Pt, and Ir Nuclei Near the Proton Dripline
… at the target position in conjunction with the Fragment Mass Analyzer (FMA) for mass identification and a Double-Sided Silicon Strip Detector (DSSD), which was used to observe the recoiling implants and the alpha particles associated with each nuclide.</p> <p>The Recoil Decay Tagging method …
-
Stability of Transfermium Elements at High Spin : Measuring the Fission Barrier of 254No
… avec les résidus d’évaporation au plan focal du Fragment Mass Analyzer ont permis de séparer les rayons γ du 254No de ceux issus de la fission, qui sont > 10^6 fois plus intenses. De ces mesures, la distribution d’entrée – c’est-à-dire la distribution initiale en I et E∗ – est reconstruite. …
-
Study οf neutrοn-deficient Μd isοtοpes and advances in the Χ-ray detectiοn system fοr particle ΙD οf superheavy elements
… à Argonne National Laboratory (ANL) à l'aide du Fragment Mass Analyzer (FMA). Dans cette étude, les isotopes Md ont été produits à l'aide de la réaction de fusion-évaporation 40Ar + 209Bi et identifiés en corrélant les noyaux de recul implantés, séparés par A/q en le FMA, avec les événements de …
-
High-spin spectroscopy on Au and a systematic study of moments of inertia in prolate rotational bands from Dy to Tl
… Ge detectors was used in conjunction with the Fragment Mass Analyzer and a double-sided silicon strip detector to make the first positive identification of excited states in <sup>179</sup>Au by the recently developed method of Recoil Decay Tagging. These states were populated in a …