Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 26 for “"Freon-113"”

  1. Effect of Velocity on Boiling Freon-113

    Made available in DSpace on 2014-12-13T18:55:43Z (GMT). No. of bitstreams: 1 8004310.pdf: 7884115 bytes, checksum: abb784c4fcb488a39906cbe1d69db75f (MD5) Previous issue date: 1979

    uiuc Repository record for Effect of Velocity on Boiling Freon-113 (opens in a new tab)

  2. Cavitation similarity studies with water and Freon-113.

    … of cavitation behind a disc in water andFreon-113 was investigated in a cavitation tunnel designed for this purpose. Measurements of pressure within the cavities formed in water indicated that the vapor pressure within the cavity was less than the vapor pressure of the fluid at the bulk …

    nps Repository record for Cavitation similarity studies with water and Freon-113. (opens in a new tab)

  3. Saturated pool and flow boiling studies with freon-113 and water at atmospheric pressure

    … at atmospheric pressure were studied using Freon-ll3 and demineralized water as test fluids. The same copper test surfaces, prepared by lapping with a 40o-grit compound, were used for all the tests. . Horizontal and vertical orientations were studied in the pool boiling facility; whereas the …

    utk-theses Repository record for Saturated pool and flow boiling studies with freon-113 and water at atmospheric pressure (opens in a new tab)

  4. Boiling Heat Transfer of Freon-113 Flowing Normal to a Tube: Effect of Tube Diameter

    … pool and flow boiling heat transfer of saturated Freon-113 was examined. The heaters were horizontal copper tubes of diameter 1.59 to 7.94 mm (pool) and 3.18 to 12.7 mm (flow), heated internally by condensing steam. The test fluid, at atmospheric pressure, flowed upward normal to the heaters, at …

    uiuc Repository record for Boiling Heat Transfer of Freon-113 Flowing Normal to a Tube: Effect of Tube Diameter (opens in a new tab)

  5. Film boiling of Freon 113, Normal Pentane, Cyclopentane, and Benzene from cylindrical surfaces at moderate pressures

    … heat transfer in saturated pools of liquid Freon 113, Normal Pentane, Cyclopentane, and Benzene was made. The fluids were boiled from copper, cylindrical heat transfer surfaces, 3 inches long, and 0.55, 0.75, and 1.00 inch in diameter. The heat transfer elements were positioned horizontally …

    must-thes Repository record for Film boiling of Freon 113, Normal Pentane, Cyclopentane, and Benzene from cylindrical surfaces at moderate pressures (opens in a new tab)

  6. Film boiling of benzene, freon 113, freon 11, and normal pentane from horizontal surfaces at atmospheric pressure

    … flat plates at atmospheric pressure for benzene, Freon 113, Freon 11, and n-pentane. The heat transfer surface was horizontal for all tests. The data were compared to the correlations commonly used for heat transfer. The common correlations were found to be in error for small surface sizes, but …

    must-thes Repository record for Film boiling of benzene, freon 113, freon 11, and normal pentane from horizontal surfaces at atmospheric pressure (opens in a new tab)

  7. An experimental study of nucleate pool boiling heat transfer from a Gewa-T finned surface in Freon-113

    … tests were made with a Gewa-T finned surface in Freon-113 to assist in understanding the physical mechanisms which occur during nucleate pool boiling from this type of surface. The influence of the channels between neighboring T-shaped fins was examined with the use of four aluminum shrouds which …

    nps Repository record for An experimental study of nucleate pool boiling heat transfer from a Gewa-T finned surface in Freon-113 (opens in a new tab)

  8. The influence of drilled cavities on natural convection heat transfer from a horizontal surface.

    … surface. Tests were run with water and Freon 113. Data for heat flux as a function of bulk temperature difference were carefully obtained. These data yielded Nusselt number as a function of Grashof number or Rayleigh number. All of these were then compared with the data obtained by …

    nps Repository record for The influence of drilled cavities on natural convection heat transfer from a horizontal surface. (opens in a new tab)

  9. Economic and Technical Feasibility of Vapor Phase Cooling of Pole-Top Distribution Transformers

    … temperatures: a) core/coil totally immersed in Freon 113 and b) a small quantity of Freon 113 with a gravity distribution system. Very good agreement existed between predicted temperature distribution and the actual test data.

    marquette Repository record for Economic and Technical Feasibility of Vapor Phase Cooling of Pole-Top Distribution Transformers (opens in a new tab)

  10. A Nanosecond Laser Spectrophotometric and Product Investigation of the Chemistry of Fluorenylidene

    … cyclopropane, spiropentane, acetonitrile, and Freon 113 spectroscopically, and chemically by isolation and characterization of products. Proposal of an equilibrium between singlet and triplet fluorenylidene has been made. Evidence has also been presented for a reassignment of transient …

    uiuc Repository record for A Nanosecond Laser Spectrophotometric and Product Investigation of the Chemistry of Fluorenylidene (opens in a new tab)

  11. Transition boiling of normal pentane from a horizontal flat gold surface

    … the transition boiling of Normal Pentane, Freon 12, Freon 113 and Freon 114"--Abstract, page iii.

    must-thes Repository record for Transition boiling of normal pentane from a horizontal flat gold surface (opens in a new tab)

  12. The influence of artificial cavities on natural convection heat transfer from a horizontal surface

    … from a horizontal surface. Tests were run with Freon 113. Data for heat flux as a function of bulk temperature difference were carefully obtained. These data yielded Nusselt number as a function of Grashof number or Rayleigh number. All of these were then compared with the data obtained by Hiep …

    nps Repository record for The influence of artificial cavities on natural convection heat transfer from a horizontal surface (opens in a new tab)

  13. Gravitational effects on the operation of a variable conductance heat pipe.

    … horizontal and vertical positions. Methanol and Freon 113 were selected as the working fluids; helium and krypton were the non-condensible gases. In the variable conductance mode, liquid crystals were used to observe qualitatively the temperature gradients occurring across the vapor-gas …

    nps Repository record for Gravitational effects on the operation of a variable conductance heat pipe. (opens in a new tab)

  14. The structural characterization of mammalian reovirus RNA-dependent RNA polymerase, capsid morphology, and capsid dynamics

    … as a suitable substitute for the organic solvent Freon 113, extensively used in virus purification. Factors affecting protein configuration, specifically of the RdRp, can have detrimental effects on transcription. To examine such factors, temperature-sensitive mutants 'tsD'357 and 'tsG'453, along …

    manitoba Repository record for The structural characterization of mammalian reovirus RNA-dependent RNA polymerase, capsid morphology, and capsid dynamics (opens in a new tab)

Page 1 of 2