Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 12 of 12 for “"Frequency Response Analysis (FRA)"”.

  1. Power Transformer Transient Modeling Using Frequency Response Analysis

    Vector Fitting is employed to approximate the Frequency Response Analysis (FRA) measurement data of a 13.8 kV/136.8 kV, 50-MVA single phase transformer. The frequency response of the primary and secondary coils as well the coupling between the coils have been measured in the frequency range of up …

    manitoba Repository record for Power Transformer Transient Modeling Using Frequency Response Analysis (opens in a new tab)

  2. CMOS Impedance Measurement Array for Cell Sensing

    … cellular samples using a mixed-signal-based frequency response analysis (FRA) approach to extract and convert the real and imaginary parts of the cell impedance. The system is implemented using a synchronous voltage-to-frequency converter designed to operate over an input frequency range from …

    waterloo Repository record for CMOS Impedance Measurement Array for Cell Sensing (opens in a new tab)

  3. Power Transformer Frequency Response Analysis: Examination of Resonance Influences on Frequency Response Analysis Signals as The Traveling Wave is Transmitted Through a Power Transformer

    … the physics associated with power transformer frequency response analysis (FRA) is required to properly interpret FRA traces for correct diagnostics of a power transformer. Events occurring within a power transformer to influence FRA test traces are explained. A complex Lorentzian curve shape is …

    umn Repository record for Power Transformer Frequency Response Analysis: Examination of Resonance Influences on Frequency Response Analysis Signals as The Traveling Wave is Transmitted Through a Power Transformer (opens in a new tab)

  4. Feasibility study of inductive heating coil with distributed resonant capacitors

    … were proposed, constructed and tested by Frequency Response Analysis (FRA) to identify the resonant frequencies. The step response tests and field tests were performed with a square wave supply and were contrasted with the expected induced magnetic field modeled in MatLab. The measurements …

    ubc Repository record for Feasibility study of inductive heating coil with distributed resonant capacitors (opens in a new tab) Download PDF for Feasibility study of inductive heating coil with distributed resonant capacitors (opens in a new tab)

  5. Diagonostic [sic] of transformer winding movement

    … are discussed and compared in this thesis. The Frequency Response Analysis (FRA) technique is today's most commonly used and effective technique; however, it highly depends on the test frequency range, test set-up, external circuits and different physical structures of different transformers. …

    ubc Repository record for Diagonostic [sic] of transformer winding movement (opens in a new tab) Download PDF for Diagonostic [sic] of transformer winding movement (opens in a new tab)

  6. Winding movement and condition monitoring of power transformers in service

    … action can be taken to prevent such failures. Frequency Response Analysis (FRA) techniques have the potential to detect winding problems, but the method also contains some uncertainty. In this thesis, Experiments on off-line and online FRA techniques were performed both in the laboratory and on …

    ubc Repository record for Winding movement and condition monitoring of power transformers in service (opens in a new tab) Download PDF for Winding movement and condition monitoring of power transformers in service (opens in a new tab)

  7. A multi-layer neural network approach to identification of mechanical damage in power transformer windings

    … to the structure of the transformer windings, is Frequency Response Analysis (FRA). FRA relies on comparison of electrical admittance signatures to determine if the winding has become deformed. One of the major problems it still faces is the interpretation of differences in the signatures. To …

    ubc Repository record for A multi-layer neural network approach to identification of mechanical damage in power transformer windings (opens in a new tab) Download PDF for A multi-layer neural network approach to identification of mechanical damage in power transformer windings (opens in a new tab)

  8. Innovative design of metamaterial structures for elastic wave absorption and structural vibration suppression

    … homogeneous bars, beams or plates. Dispersion analysis is used to find the band gap for infinite metamaterial structures without damping. Frequency response analysis (FRA) and transient analysis are conducted for metamaterial structures with boundary conditions and damping. The work explains …

    missouri Repository record for Innovative design of metamaterial structures for elastic wave absorption and structural vibration suppression (opens in a new tab)

  9. New approaches to improve the performance of the PEM based fuel cell power systems

    … model of the fuel cell stack is derived by a frequency response analysis (FRA) technique to evaluate the effects of the ripple current generated by the power-conditioning unit. Experimental results are presented to show the effects of the ripple currents. In the second section, a fuel cell …

    tamu Repository record for New approaches to improve the performance of the PEM based fuel cell power systems (opens in a new tab)

  10. Transformer Winding Deformation and Insulation Characteristic Effects on Frequency Response Analysis

    Frequency Response Analysis (FRA) is considered an accurate, fast, economical and non-destructive method for the detection of winding deformation within power transformers, providing detailed information on electrical properties of this asset. Changes in winding configuration, as well as other …

    unsw Repository record for Transformer Winding Deformation and Insulation Characteristic Effects on Frequency Response Analysis (opens in a new tab)

  11. CMOS Universal Real-time Label-free DNA Analysis System-on-Chip

    … temperature regulation. Cyclic voltammetry DNA analysis and pH sensing is implemented by utilizing the current-to-digital channel and an on-chip programmable waveform generator. The current-to-digital channel is multiplexed between a bank of DNA sensors and a pH sensor. The on-chip programmable …

    toronto-retro Repository record for CMOS Universal Real-time Label-free DNA Analysis System-on-Chip (opens in a new tab)

  12. Analogový potenciostat pro měření osciloskopem s funkcí Bode plot

    Tato práce se zabývá návrhem a testováním modulu tříelektrodového analogového potenciostatu, určeného pro měření impedance kapalin ve frekvenčním rozsahu od 10 Hz do 10 MHz. Samotné zařízení je koncipováno jako rozšiřující modul pro osciloskopy Keysight řady DSO-X 3000 a Keysight řady DSO-X 1202G, …

    brno-tech Repository record for Analogový potenciostat pro měření osciloskopem s funkcí Bode plot (opens in a new tab)