Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 24 for “"Friction dampers"”.

  1. Development of Electromagnetic Friction Dampers for Improving Seismic Performance of Civil Structures

    … to extreme natural events such as earthquakes. Friction is one of the most reliable mechanisms of energy dissipation that has been utilized extensively in friction dampers to improve seismic performance of civil structures. Friction dampers are well-known for having a highly nonlinear hysteretic …

    cuny Repository record for Development of Electromagnetic Friction Dampers for Improving Seismic Performance of Civil Structures (opens in a new tab)

  2. Seismic Damage Avoidance Concrete Shear Walls Using New Self-Centring Friction Dampers

    Past severe earthquakes imposed considerable life and financial loss to earthquake-prone countries. In the 2011 Christchurch earthquake, most of the buildings designed for the code requirements performed as expected and saved lives. However, a big financial loss was imposed on the economy to repair …

    auckland-tech Repository record for Seismic Damage Avoidance Concrete Shear Walls Using New Self-Centring Friction Dampers (opens in a new tab)

  3. Semi-active control of elastic and inelastic building structures with piezoelectric friction dampers

    … devices. In this study, a piezoelectric friction damper (PFD) was first introduced with its clamping force regulated by piezoelectric stack actuators. A new semi-active control algorithm, which consists of Coulomb friction, viscous and non-linear Reid damping mechanisms, was proposed to …

    must-thes Repository record for Semi-active control of elastic and inelastic building structures with piezoelectric friction dampers (opens in a new tab)

  4. Impact of friction dampers and ductility factor on the seismic response of concrete moment resisting frame buildings

    … vibration response. This research focuses on friction devices, particularly, the inline friction dampers used in diagonal bracings to control the vibration in buildings. There is no standard design process available in the National Building Code of Canada to design buildings with friction …

    concordia Download PDF for Impact of friction dampers and ductility factor on the seismic response of concrete moment resisting frame buildings (opens in a new tab)

  5. Seismic resilience and performance design approach for concrete moment resisting frame buildings equipped with yielding restrained braces

    … be classified into six types including Metallic Dampers, Friction Dampers, Viscoelastic Dampers, Viscous Fluid Dampers, Tuned Mass Dampers, and Tuned Liquid Dampers. The primary purpose of this research is to decrease structural damage by minimizing the demand for main structural elements through …

    concordia Download PDF for Seismic resilience and performance design approach for concrete moment resisting frame buildings equipped with yielding restrained braces (opens in a new tab)

  6. Numerical Study and Optimization of Post-Tensioning Energy Dissipating Connections with Inerters

    … and includes energy dissipating (ED) bars, friction dampers, and steel angles located at the top and bottom of the beam-to-column connections. The Post-Tensioned Energy dissipating (PTED) connection reduces inelastic deformation to the beams and columns, is installed with minimum welding, …

    ucf Repository record for Numerical Study and Optimization of Post-Tensioning Energy Dissipating Connections with Inerters (opens in a new tab)

  7. Energy Redistribution with Controllable Binary State Latch Element

    … device can be viewed as variable semi-active dampers such as magnetorheological (MR) and piezoelectric friction dampers. The distinct difference between other semi-active dampers and our latch device is that other semi-active dampers can provide continuous resistance according to the amount of …

    vt Repository record for Energy Redistribution with Controllable Binary State Latch Element (opens in a new tab)

  8. Design of viscous and friction damper systems for the optimal control of the seismic response of structures

    … methods for the optimal design of viscous or friction/hysteretic dampers in structures subjected to seismic and other dynamic loads. The systems investigated to control the dynamic response of the structure included passive linear viscous dampers, constant slip force friction dampers, and …

    ubc Repository record for Design of viscous and friction damper systems for the optimal control of the seismic response of structures (opens in a new tab) Download PDF for Design of viscous and friction damper systems for the optimal control of the seismic response of structures (opens in a new tab)

  9. Development of New Self-centring Rocking Systems by Incorporating Resilient Slip Friction Mechanisms: Applications in Structures and Storage Tanks

    … limits. The utilization of self-centring friction dampers, which includes both restoring and energy damping features, is particularly advantageous for rocking system applications. This research focused on the seismic performance of two distinct applications of rocking systems equipped with …

    auckland-tech Repository record for Development of New Self-centring Rocking Systems by Incorporating Resilient Slip Friction Mechanisms: Applications in Structures and Storage Tanks (opens in a new tab)

  10. Use of Permanent Magnets to Improve the Seismic Behavior of Light-Framed Structures

    … magnets, incorporated in the form of passive friction dampers, to dissipate a part of input energy induced due to strong ground motions, thereby reducing the inelastic energy dissipation demand of the lateral load resisting system. The force of attraction between the permanent magnet and …

    vt Repository record for Use of Permanent Magnets to Improve the Seismic Behavior of Light-Framed Structures (opens in a new tab)

  11. Seismic design of energy dissipation systems for optimal structural perfromance

    … been examined in the study: (1) viscous fluid dampers, (2) viscoelastic dampers, (3) yielding metallic dampers and, (4) friction dampers. For each type of energy dissipation system, the study presents the (a) formulation of the optimal design problem, (b) consideration of several meaningful …

    vt Repository record for Seismic design of energy dissipation systems for optimal structural perfromance (opens in a new tab)

  12. Seismic Interstory Drift Demands in Steel Friction Damped Braced Buildings

    … have proposed, developed and tested different friction devices for seismic control of structures. Their research has demonstrated that such devices are simple, economical, practical, durable and very effective. However, research on passive friction dampers, except for few instances, has not …

    tamu Repository record for Seismic Interstory Drift Demands in Steel Friction Damped Braced Buildings (opens in a new tab)

  13. Numerical Simulations of Steel Frames Equipped with Friction-Damped Diagonal-Bracing Devices

    Among passive energy dissipation devices, friction dampers are used worldwide as means of increasing damping into structural building systems with the aim to reduce the seismic response. These devices, added either in-line with diagonal braces, or at the intersection zone of X- and chevron-bracing …

    concordia Download PDF for Numerical Simulations of Steel Frames Equipped with Friction-Damped Diagonal-Bracing Devices (opens in a new tab)

  14. Seismic design and evaluation of self-centering modular rocking composite sandwich wall (SC-MRCSW) system

    … of the SC-MRCSW, novel self-centering friction dampers are added to the system to ensure SC-MRCSW system can dissipate earthquake energy and self center after strong earthquake shaking. This makes SC-MRCSW system highly resilient. This thesis focuses on the seismic design of SC-MRCSW …

    ubc Repository record for Seismic design and evaluation of self-centering modular rocking composite sandwich wall (SC-MRCSW) system (opens in a new tab) Download PDF for Seismic design and evaluation of self-centering modular rocking composite sandwich wall (SC-MRCSW) system (opens in a new tab)

  15. Development of a novel self-centering balloon-type CLT shear wall system for tall buildings

    … and coupled to one another using self-centering friction dampers. Optional V-shaped truss assemblies can also be used at the base of the panels. This thesis also presents a procedure that can be used to design the DSCW. This procedure is a modified version of the equivalent energy design …

    ubc Repository record for Development of a novel self-centering balloon-type CLT shear wall system for tall buildings (opens in a new tab) Download PDF for Development of a novel self-centering balloon-type CLT shear wall system for tall buildings (opens in a new tab)

  16. Vibration control and mitigation in turbomachinery

    … vibrations, designers frequently incorporate dry friction devices into turbine designs. Typical examples of friction dampers are shrouds, snubbers and underplatform dampers. Despite the continuous effort found in the literature in terms of modeling and optimization strategies, the lack of …

    poli-torino Repository record for Vibration control and mitigation in turbomachinery (opens in a new tab)

  17. Development of an innovative earthquake-resilient reinforced concrete core wall system

    … at the roof and the base is designed to rock. Dampers are incorporated within the outrigger and the rocking base to give CORW added energy dissipation. Along the other principal axis is the self-centering coupled wall (SCCW). In the SCCW system, self-centering friction dampers are incorporated …

    ubc Repository record for Development of an innovative earthquake-resilient reinforced concrete core wall system (opens in a new tab) Download PDF for Development of an innovative earthquake-resilient reinforced concrete core wall system (opens in a new tab)

  18. Semiaktiv stötdämpning till Stridsfordon 90

    … of trailing arms, torsion bars and rotary friction dampers. Each damper contains a wet lamella clutch brake which is pressurized by a piston connected to the trailing arm. The damper operates according to the ground-hook theory where damping torque is proportional to the trailing arm …

    chalmers Repository record for Semiaktiv stötdämpning till Stridsfordon 90 (opens in a new tab)

  19. Collapse Safety Assessment of Steel Multi-storey Buildings with Friction Sliding Braced Frames and Backup Moment Resisting Frames as a Dual System

    … saw the first application of cross-braced Pall friction dampers (PFD). Although PFDs have evolved and improved, including the friction material used, development of the design procedure has been limited. Using a recently proposed force-based design method and considering detailed computational …

    concordia Download PDF for Collapse Safety Assessment of Steel Multi-storey Buildings with Friction Sliding Braced Frames and Backup Moment Resisting Frames as a Dual System (opens in a new tab)

  20. Investigation of Modular Cross-Laminated Timber Rocking Walls and Rocking Wall -- Light-Frame Shear Wall Dual Systems for Seismic Resilience

    … on the wall's backbone and cyclic behavior. Friction dampers integrated at the base connections provided supplemental damping while maintaining fabrication simplicity. Predictive equations and nonlinear numerical models were developed and validated against test data, offering tools to support …

    vt Repository record for Investigation of Modular Cross-Laminated Timber Rocking Walls and Rocking Wall -- Light-Frame Shear Wall Dual Systems for Seismic Resilience (opens in a new tab)

Page 1 of 2