Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 34 for “"Fringe field"”.

  1. New fringe-field capacitive sensors.

    ottawa-retro Repository record for New fringe-field capacitive sensors. (opens in a new tab)

  2. Fringe Field Corrections in nvCPD Probe Tip Applications

    … and an analytical model was developed, including fringe electrical fields, that predicts the shape of the nvCPD probe signal as a function of probe tip geometry, work function variation, and experimental parameters. Probe tips were constructed with varying geometric properties and experiments …

    gatech Repository record for Fringe Field Corrections in nvCPD Probe Tip Applications (opens in a new tab)

  3. Soil permittivity determination using a fringe field capacitor

    … into three sections: (1) design of the fringe field dielectric sensor, (2) development of instrumentation and equations required to calculate permittivity parameters and (3) testing of the system in soil. A double-cylinder configuration was selected and results from solving Laplace's …

    nebraska Repository record for Soil permittivity determination using a fringe field capacitor (opens in a new tab)

  4. Calibration of the chaos spectrometer for small scattering angles

    … The out-of-plane information from WC4 requires a fringe field correction, because it lies outside the uniform magnetic field of CHAOS. The fringe field of CHAOS acts like a lens, in that it has a slight focusing effect on charged particles. The fringe field correction moves the WC4 (x,y,z) data …

    ubc Repository record for Calibration of the chaos spectrometer for small scattering angles (opens in a new tab) Download PDF for Calibration of the chaos spectrometer for small scattering angles (opens in a new tab)

  5. Compatibility of X-ray Tubes with Magnetic Resonance Imaging Scanners for Aortic Valve Replacement

    … of a rotating-anode x-ray tube in the magnetic fringe field of a 1.5 T MRI scanner was investigated. A rotating-anode x-ray tube provides the fluoroscopy and angiography needed for PAVR. The magnetic fringe field can affect the ability of the x-ray tube to dissipate heat. It was shown that the …

    toronto-retro Repository record for Compatibility of X-ray Tubes with Magnetic Resonance Imaging Scanners for Aortic Valve Replacement (opens in a new tab)

  6. Magnetic field measurements in quadrupole magnets

    Magnetic field measurements have been made on a 4" diameter aperture beam-line quadrupole magnet. One method of measurement uses a rotating coil with a narrow bandwidth wave analyzer and the other a Hall plate survey system interfaced to an on-line mini-computer. The measurements are analyzed to …

    uvic Repository record for Magnetic field measurements in quadrupole magnets (opens in a new tab)

  7. Beam injection and Matching Studies in the University of Maryland Electron Ring

    … crucial. Injection is done through a quadrupole fringe field, making it more challenging. Careful injection of a matched beam will also minimize emittance growth and halo formation around the ring. In this thesis, experimental results from the injection, matching, and transport of a space charge …

    maryland Repository record for Beam injection and Matching Studies in the University of Maryland Electron Ring (opens in a new tab)

  8. Studies of the effects of non-linear materials in the CREX septum magnet using finite element analysis simulations

    … the equipment, the septum magnet needs to meet field requirements suitable for CREX. As the magnet is iron-dominated the field response is non-linear at sufficiently high current. This is of particular concern for CREX which is run at a beam energy more than double that of PREX-2 and requires a …

    manitoba Repository record for Studies of the effects of non-linear materials in the CREX septum magnet using finite element analysis simulations (opens in a new tab)

  9. An experimental investigation of the wall-pressure field during turbulent incompressible pipe flow

    … structure of the turbulent wall-pressure field. The approach involved the use of real-time laser-holographic-moiré interferometry. A moiré fringe pattern generated by the holographic method was superimposed on the surface of a specially-fabricated compliant pipe wall. The compliant …

    ubc Repository record for An experimental investigation of the wall-pressure field during turbulent incompressible pipe flow (opens in a new tab) Download PDF for An experimental investigation of the wall-pressure field during turbulent incompressible pipe flow (opens in a new tab)

  10. Microengineered silicon beam switch for fiber optics

    … moves orthogonally with respect to the electric field vectop between the principal stator and armature. Actuation force is derived from the fringe field at the armature. A total of 772 three phase pole groups comprise the stator configuration. The stator poles are arranged into 8 separate linear …

    njit Repository record for Microengineered silicon beam switch for fiber optics (opens in a new tab)

  11. Rotary micromotor design with IC-compatible processing

    … These micromotors obtain drive torque from the fringe-field differential at the periphery of the rotor poles.</p><p>Unlevitated micromotors (with bearings) have been modeled with the number of rotor poles varying from 4 to 8 and stator poles varying from 12 to 120. Micromotors with a levitated …

    njit Repository record for Rotary micromotor design with IC-compatible processing (opens in a new tab)

  12. A nonlinear regression approach to the use of the hole method in photoelasticity

    … equation is developed which relates the stress field, expressed as isochromatic fringe orders surrounding the central hole, to the far-field stresses, a 1 and a2 • By the application of an over-deterministic approach, which utilizes the Levenberg-Marquardt Method coupled with a Least Squares …

    ttu Repository record for A nonlinear regression approach to the use of the hole method in photoelasticity (opens in a new tab)

  13. Evaluation of Phenol Formaldehyde Resin Cure Rate

    … resins using parallel-plate rheometry, fringe-field dielectric analysis, and parallel-plate dielectric analysis. The general shape of the storage modulus vs. time curve and the gel and vitrification points in a temperature ramp were found. Both dielectric analysis techniques were able to …

    vt Repository record for Evaluation of Phenol Formaldehyde Resin Cure Rate (opens in a new tab)

  14. Tracking optimisation and the measurement of K+->π+μ+μ- at NA62

    … procedure have been developed. Firstly, a field map which describes the fringe field of the spectrometer magnet has been created, tested and implemented in the NA62 Monte-Carlo software. Additionally, an analysis procedure to improve the precision and accuracy of track momentum in data was …

    birmingham Download PDF for Tracking optimisation and the measurement of K+->π+μ+μ- at NA62 (opens in a new tab)

  15. Calculation of Realistic Charged-Particle Transfer Maps

    … can in general depend sensitively on nonlinear fringe-field and high-multipole effects. The inclusion of these effects requires a detailed and realistic model of the interior and fringe magnetic fields, including knowledge of high spatial derivatives. Current methods for computing such maps …

    maryland Repository record for Calculation of Realistic Charged-Particle Transfer Maps (opens in a new tab)

  16. Developing hydrodynamic sensing capabilities for fish-like robots

    … air, are becoming an increasing reality and a field of rapid development. Used for ocean exploration, asset monitoring and harbour security, they withstand high pressures, salt water and rough conditions to provide information and manipulation capabilities. Biomimetic, fish-like robots offer …

    auckland-ms Repository record for Developing hydrodynamic sensing capabilities for fish-like robots (opens in a new tab)

  17. Advanced liquid crystal displays with supreme image qualities

    … from 5000:1 to 20,000:1, and the CR for a fringe field switching LCD is improved from 2000:1 to over 3000:1. To further enlarge CR to fulfill the high dynamic range requirement, a dual-panel LCD system is proposed and the measured contrast ratio exceeds 1,000,000:1. Overall speaking, such …

    ucf Repository record for Advanced liquid crystal displays with supreme image qualities (opens in a new tab)

Page 1 of 2