Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 25 for “"Full Matrix Capture"”
-
Développement d’une méthode de reconstruction ultrasonore pour la localisation et la caractérisation de défauts
… techniques d’acquisition avancées, telle que la Full Matrix Capture, permettent d’avoir accès à des données beaucoup plus riches et complètes que celles fournies par les techniques conventionnelles, offrant ainsi de nouvelles possibilités en terme de localisation et de caractérisation de défauts. …
-
Metallic material grain structure characterization using ultrasonic arrays
… transducers is adapted to be used for<br/>full matrix capture datasets from an ultrasonic array. Three-dimensional ultrasonic models are<br/>developed in the proposed inverse process to measure material microstructure grain size. Both<br/>three-dimensional and two-dimensional forward wave …
-
Laser induced phased arrays for volumetric imaging
… independently of each other, in order to capture the signal from each generation and detection element combination.This data acquisition method is called the Full Matrix Capture. Images are formed in post-processing by synthetically focusing on each pixel of the image, using a …
-
Imagerie ultrasonore par réseaux antagonistes génératifs conditionnels (cGAN)
… DAS) en combinaison avec une acquisition de type capture matricielle complète (de l’anglais Full-Matrix-Capture : FMC) est une méthode encore aujourd’hui extrêmement utilisée dans le contrôle non destructif pour un grand nombre d’applications d’imagerie ultrasonore. Cependant, dans certains cas, …
-
Méthode automatique de détermination des paramètres d'inspection ultrasonore pour la reconstruction TFM
… ces paramètres à partir de la donnée FMC (« Full Matrix Capture » en anglais) utilisée pour reconstruire l’image TFM. Deux approches ont été proposées pour résoudre ce défi. La première, analytique, repose sur la comparaison des temps de vol réels et théoriques des échos structuraux, mais …
-
Imaging and defect characterisation using multi-view ultrasonic data in nondestructive evaluation
… testing for a wide range of inspections. The Full Matrix Capture (FMC) acquisition technique allows the capture of all the information possibly measurable by the probe. The Total Focusing Method (TFM) forms images by post-processing the FMC data, superseding conventional phased array …
-
Ultrasonic Non-Destructive Evaluation of Lithium-Ion Battery Health Status
… validation demonstrates that this model successfully captures key ultrasonic characteristics, including the presence of a secondary longitudinal wave unique to porous media.</p> <p>Building on this model, ultrasonic spectroscopy is employed to detect early-stage Li plating by analyzing changes …
-
Towards in-process robotic ultrasonic weld geometry estimation and lack of sidewall fusion monitoring
… Oriented Gradients (HOG) estimation to achieve Full Matrix Capture data compression exceeding 88% while extracting bevel orientation to within 0.4° in under 250 ms. Finally, a machine learning pipeline is presented in Chapter 7, employing data augmentation; using Gaussian Process Regression …
-
Phased-array ultrasonic residual stress measurement in metal additive manufacturing : development, validation, and microstructure-aware interpretation
… in Time-of-Flight (ToF) into RS measurements. Full Matrix Capture (FMC) allows averaging multiple paths and assessing the quality of each path, increasing measurement redundancy and reducing variability. PAURS+ is also examined as a microstructure-aware extension of PAURS. PAURS was assessed …
-
Automated ultrasound in-process NDE of wire + arc additive manufacture
… is developed to process the acquired ultrasound Full Raw Data (FRD) called Full Matrix Capture (FMC).The developed system is then deployed in-process, delivering, for the first time, ultrasound in-process inspection of as-built titanium WAAM components. Lastly, realizing the drawbacks limiting …
-
Development and implementation of an alternative method for complete characterization of surface-breaking cracks using ultrasonic Rayleigh waves
… method is introduced for acquiring Rayleigh wave full matrix capture (FMC), which is then utilized with the total focusing method (TFM) imaging algorithm to generate images of surface cracks. This comprehensive approach allows for the complete characterization of surface cracks, including length …
-
Ultrasonic and Eddy Current Non-Destructive Evaluation of Near-Surface Flaws in Additively Manufactured Metal
… of phased array ultrasonic testing (PAUT) and full matrix capture with the total focusing method (FMC/TFM) were evaluated for their abilities to detect, localize, and size near-surface side-drilled holes (SDHs) in AM Ti–5Al–5V–5Mo–3Cr. Both techniques proved effective for inspection. FMC/TFM …
-
Inspection de blocs d'acier forgé de grand volume par ultrasons multi-éléments
… ont été comparées aux séquences de type Full-Matrix-Capture (FMC). Une amélioration du Ratio Signal sur Bruit (RSB) a été observée pour les ondes planes mais les performances de résolutions ont été diminuées. Ce résultat confirme que l’énergie transmise dans le matériau est supérieure …
-
Imaging methodologies applied on phased array ultrasonic data from austenitic welds and claddings
The increasing trend to use austenitic welded and cladded materials in critical components employed in some industrial sectors, such as the oil&gas and nuclear industries, leads to an increasing demand for their non-destructive assessment by reliable non-destructive methods. Among the methods used …
-
A Statistical Approach to Ultrasonic Inspection for Complex Geometry
… volume of a component through techniques such as full matrix capture and the total focusing method (TFM). By exploiting mode conversions as the wave skips from boundaries in the geometry, the TFM may be extended to provide additional views that can aid in detection of flaws. This has the benefit …
-
Volumetric Imaging Using 2D Phased Arrays
… of industrial components. Their use allows the full-matrix capture (FMC) acquisition technique to be used; this contains all possible information of an inspection for a specific array location, and therefore allows a number of imaging algorithms to be applied in post-processing. One such …
-
Non-destructive Evaluation of Ceramic Matrix Composites at High Temperature using Laser Ultrasonics
Ceramic matrix composites (CMCs) are poised to revolutionize jet engine technologyby enabling operation temperatures well beyond those possible with current superalloys,while reducing active cooling requirements and engine weight. Manufacturing of partsformed by silicon-carbide (SiC) fibers in a …
-
Considerations for an in-process ultrasonic phased array inspection method for narrow gap welds
… and though-weld detection. Coupled with Full Matrix Capture (FMC) acquisition and Total Focusing Method (TFM) imaging, it has been shown that vertical notch defects can be detected with high Signal-to-Noise Ratio (SNR) using this method in a mock-narrow gap weld setup through the use of …
-
Coded excitation with lead-free ultrasonic arrays : from complex structural integrity assessments to intravascular ultrasound imaging
… Coded excitation strategies in conjunction with Full Matrix Capture (FMC) and Total Focusing Method (TFM) were applied to inspect thick non-planar industrial components. The Golay-based TFM demonstrated superior performance compared to the pulse-based TFM. Golay excitation strategies offer …
-
Enhancing Image Repeatability with Ultrasonic Array
… The use of phased array transducers enables the full-matrix capture (FMC)<br/>acquisition technique which captures all available information regarding an inspection<br/>at a given location. This technique enables the application of various imaging algorithms<br/>in post-processing. One algorithm …
Page 1 of 2