Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 826 for “"Full field"”
-
Full field strain measurement in welds
… a weld subjected to some nominal loading using a full- field surface strain mapping technique. This process makes use of the digital image correlation program (VIC_2D) developed by the University of South Carolina. Full-Field surface strain mapping will be used to help determine the basic material …
-
Thermoelastic and photoelastic full-field stress measurement
… of the principal stresses. Combining these two full-field, non-contact nondestructive evaluation techniques allows the individual stress components to be measured. One of the main difficulties in merging these two measurement systems is in identifying an appropriate surface coating. …
-
FULL-FIELD DAMAGE ASSESSMENT OF NOTCHED CFRP LAMINATES
… the first dedicated application of surface full-field experimental techniques to the comprehensive damage assessment of open-hole compression (OHC) in composite laminates, under both static and fatigue loading. The relevance of the work comes from OHC being one of the two main tests used in …
-
Ameliorating Systematic Errors in Full-Field AMCW Lidar
… presents an analysis of systematic error in full-field amplitude modulated continuous wave range-imaging systems. The primary focus is on the mixed pixel/multipath interference problem, with digressions into defocus restoration, irregular phase sampling and the systematic phase perturbations …
-
Full-field modelling of crack tip shielding phenomena
… are complicated, and have not been fully understood. This work focuses on the plasticity-induced crack tip shielding mechanism and presents a novel approach to characterise the elastic stress fields under the influence of the plastic enclave surrounding the crack tip. The model is …
-
Cancer Detection in Full Field Optical Coherence Tomography Images
Le cancer est une des principales cause de décès dans le monde et donc un problème majeur de santé publique. Plusieurs techniques d'imagerie biomédicale servent à la recherche et aux efforts cliniques pour améliorer le pronostic du patient. Nous étudions l'utilisation d'une nouvelle famille de …
-
Development of Novel Coatings for Full Field Strain Measurements
… with the automated RPE imaging device — the Grey Field Polariscope (GFP). The choice of UV curable materials provides a new range of rapid application coatings boasting a 20 s cure time whilst possessing similar RPE sensitivities of existing commercial products. Additionally, the coating was …
-
Embedded Digital Image Correlation in a Full-Field Displacement Sensor
… algorithm, which is used for measuring the full-field displacement of the surface of a structure under load. The main goal of this thesis is to develop technology needed for a portable sensing unit for calculating the full-field displacement. The portable sensing unit consists of an embedded …
-
Full-field reservoir simulation and optimisation with advanced well completions
… be used by reservoir engineers to evaluate the full range of advanced well completions (AWCs), (e.g., passive inflow control device (PICD), Autonomous inflow control device (AICD) and interval control valve (ICV) completions) and identify their optimum design in large full-field models with …
-
Fatigue Life Estimation and Validation Using Full-Field Strain Measurements
… Effect of elastic-plastic stress-strain field near the crack tip due to stress concentration on fatigue life estimation is still a topic of continued research. The objectives of this thesis are to study these two challenges. Specific objectives are to study (1) effect of frequency of …
-
TASK SPECIFIC EVALUATION METHODOLOGY FOR CLINICAL FULL FIELD DIGITAL MAMMOGRAPHY
… is to evaluate the image quality of clinical Full Field Digital Mammography (FFDM) systems. This is done by evaluating image acquisition performance of clinical FFDM in a comprehensive way that accounts for scatter, focal spot un-sharpness, detector blur and anti-scatter grid performance using …
-
Specimen radiography: digital breast tomosynthesis versus full field digital mammography
… in specimen radiography performed by routine full-field digital mammography (FFDM) with corresponding histopathology is still very disappointing. The present study was performed to evaluate the usability of digital breast tomosynthesis (DBT) in performing specimen radiography and to measure …
-
Full Field Propagation Models And Methods For Extreme Nonlinear Optics
… models, methods, and applications of electric field pulse propagation in nonlinear optics. Standard nonlinear optical propagation models such as the NLS equation are derived using a procedure invoking a slowly-varying wave approximation which amounts to discarding second order derivatives in …
-
Full-field PIXE imaging using a Colour X-ray Camera
A novel combination of a full-field X-ray detector and particle-induced X-ray emission (PIXE) as an established analytical method has been assembled and examined at the Helmholtz-Zentrum Dresden-Rossendorf (HZDR). The so-called Colour X-ray Camera (CXC) based on a pn-junction charge-coupled device …
-
Full-field deformation measurement in wood using digital image processing
… system was used to non-destructively measure the full-field deformation on aluminum and wood specimens loaded in compression and bending. The measurement technique consisted of creating a random speckle pattern on the specimen surface, recording images before deformation and after deformation, and …
-
Full field modeling of discontinuous dynamic recrystallization in a CPFEM context
La recristallisation dynamique (DRX) est l'un des principaux phénomènes métallurgiques responsable de l'évolution de la microstructure des matériaux métalliques survenant lors de luer mise en forme à chaud. Comprendre et prévoir ce phénomène physique est d'une importance primordiale car la …
-
Full-field multi-fidelity surrogate models for optimal design of turbomachines
L’optimisation des différents composants d’une turbomachine reste encore un sujet épineux, malgré les récentes avancées théoriques, expérimentales ou informatiques. Cette thèse propose et investigue des techniques d’optimisation assistées par méta-modèles vectoriels multi-fidélité basés sur la …
-
Development of a full-field time-of-flight range imaging system
A full-field, time-of-flight, image ranging system or 3D camera has been developed from a proof-of-principle to a working prototype stage, capable of determining the intensity and range for every pixel in a scene. The system can be adapted to the requirements of various applications, producing high …
Page 1 of 42