Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 7 of 7 for “"Full-scale experimental test"”
-
The bond behaviour and flexural capacity of profiled steel reinforced CRC composite slab
… construction. Investigations included small-scale and full-scale experimental test programs, and finite element modelling. At similar compressive strength, the overall structural performance of CRC composite slabs is equivalent to that of CC at both local interaction and full-scale behaviour …
-
Designing Moment-resisting Connection for Disassembly for Implementation in Precast Reinforced Concrete Buildings
… reported in this dissertation based on the experimental investigation and numerical study carried out. The proposed DfD connection was shown to possess significant moment resistance based on theoretical calculations and preliminary numerical analysis. A three-phase full scale experimental …
-
Active control of floor vibrations
… of alternative repair measures, analytical and experimental research implementing active control techniques was conducted to improve the vibration characteristics of problem floors. Specifically, a control scheme was developed utilizing the measured movement of the floor to compute the input …
-
Experimental Testing and Behavior of TxDOT "Poor Boy Joint" Link Slab Detail Using Flush Panels
… have focused on debonded link slabs. A full-scale experimental test has not been presented in literature for a fully bonded link slab let alone for the “Poor Boy Joint” link slab detail used by TxDOT. This thesis involves the development of an experimental test setup capable of loading …
-
Alternative Design of Column Web Doubler Plates in Steel Pipe Rack Modules
… fillet welds in pipe rack module connections, a full-scale experimental test setup was developed. The experimental study consisted of twelve moment connections, where each six specimens represented a different beam-to-column W-section. Six used W250×58 beams and columns and the rest used W410×60 …
-
Novel Remediation for Buried Pipelines under Ground Deformation
… technique is first presented, followed by the experimental test program developed to evaluate the beneficial effects of the SGB on the local pipe response when subjected to lateral and oblique displacements. In addition, a simplified spring-based analytical modelling approach was proposed for …
-
Seismic Response and Design of Steel Multi-Tiered Eccentrically Braced Frames
… progressive yielding of the links until full plastic mechanism develops causes non-uniform distribution of inelastic lateral deformation along the frame height, where the largest inelastic deformation tends to occur in the tier with the largest design shear to shear strength ratio. This …