Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 140 for “"Full-scale tests"”.

  1. Column-Supported Embankments: Full-Scale Tests and Design Recommendations

    … test procedures are described. A total of 5 CSE tests were conducted with 2 ft diameter columns in a square array. The first test had a column center-to-center spacing of 10 ft and the remaining four tests had center-to-center spacings of 6 ft. The Adapted Terzaghi Method of determining the …

    vt Repository record for Column-Supported Embankments: Full-Scale Tests and Design Recommendations (opens in a new tab)

  2. Bracing of steel bridges during construction; theory, full-scale tests and simulations

    … include the derivation of analytical solutions, full-scale laboratory testing, and numerical modeling. The results of a part of the study showed that the load-carrying capacity of The Marcy Bridge that collapsed in 2002 could be improved by adding top flange plan bracing at 10-20% of its span …

    lund Repository record for Bracing of steel bridges during construction; theory, full-scale tests and simulations (opens in a new tab) Download PDF for Bracing of steel bridges during construction; theory, full-scale tests and simulations (opens in a new tab)

  3. Full Scale Tests on the Performance of Hybrid Timber Connections in Real Fires

    Connections form an integral part of any building system. Concerns are raised when dealing with hybrid connections especially in fire. This is because different materials with varying ambient and thermal properties must perform together to ensure a stable structural system. This research seeks to …

    carleton Repository record for Full Scale Tests on the Performance of Hybrid Timber Connections in Real Fires (opens in a new tab)

  4. Full Scale Tests on the Discharge Characteristics, Drainage Characteristics and Fire Suppression Performance of Portable Compressed Air Foam System

    … conditions were determined. Discharge range tests and flow rate test indicated a linear progression with increasing pressure. Overall, all the tested foams met the requirements of the CAN/ULC-S508 standard. The drainage characteristics of foams, with and without thermal radiation, were …

    carleton Repository record for Full Scale Tests on the Discharge Characteristics, Drainage Characteristics and Fire Suppression Performance of Portable Compressed Air Foam System (opens in a new tab)

  5. Technological approaches to improve the engine efficiency and to reduce pollutant emissions of automotive diesel engines.

    … incompatible were assessed through a set of full- scale tests on a real diesel engine in order to satisfy the new emissions limits. (1) The first strategy evaluated in this work to improve the engine efficiency was the reduction of the mechanical losses: through the incorporation of …

    poli-torino Repository record for Technological approaches to improve the engine efficiency and to reduce pollutant emissions of automotive diesel engines. (opens in a new tab)

  6. Lateral Torsional Buckling of Wood Beams

    … program consists of conducting material tests to determine the longitudinal modulus of elasticity and rigidity modulus followed by a series of 18 full-scale tests. The buckling loads and mode shapes are documented. The numerical component of the study captures the orthotropic constitutive …

    ottawa-retro Repository record for Lateral Torsional Buckling of Wood Beams (opens in a new tab)

  7. Concrete wall subjected to fragment impacts - Numerical analyses of perforation and scabbing

    … were verified by results of already performed full-scale tests. The model was calibrated from information gained from a parameter study of the most important parameters such as tensile strength, softening energies, strain rate and shear strength. It was found out that by a calibration of the …

    chalmers Repository record for Concrete wall subjected to fragment impacts - Numerical analyses of perforation and scabbing (opens in a new tab)

  8. Analytical Model of Cold-formed Steel Framed Shear Wall with Steel Sheet and Wood-based Sheathing

    … shear walls is capacity-based and developed from full-scale tests. The available design provisions provide nominal shear strength for only limited wall configurations. This research focused on the development of analytical models of cold-formed steel framed shear walls with steel sheet and …

    unt Repository record for Analytical Model of Cold-formed Steel Framed Shear Wall with Steel Sheet and Wood-based Sheathing (opens in a new tab)

  9. Compartment Fire Toxicity: Measurements and Aspects of Modelling

    … for faster generation of such data on bench scale apparatus. The models for overall toxicity assessment (for irritants and asphyxiants) were reviewed and the reported threshold limits for typical smoke toxicants, were collected, categorised and compared for increasing levels of harm. An …

    whiterose Download PDF for Compartment Fire Toxicity: Measurements and Aspects of Modelling (opens in a new tab)

  10. Experimental Investigation of Lateral Torsional Buckling of Gerber Frames

    … buckling resistance of Gerber frames based on full scale tests and finite element analyses. Three experiments were undertaken to obtain elastic buckling loads and the buckling modes were recorded. Shell finite element solutions were conducted to predict the elastic lateral buckling resistance …

    ottawa-retro Repository record for Experimental Investigation of Lateral Torsional Buckling of Gerber Frames (opens in a new tab)

  11. Fire Performance of Hybrid Timber Connections

    … a glulam beam and a steel column by conducting full scale tests and finite element modeling. The experimental part of this research consisted of a series of full-scale tests conducted in compliance with CAN/ULC-S101. Three different types of connections were investigated, Concealed shear tabs, …

    carleton Repository record for Fire Performance of Hybrid Timber Connections (opens in a new tab)

  12. Geosynthetic-reinforced soil retaining walls subjected to surcharge loads

    … number of retaining structures have been successfully constructed using geosynthetic reinforcement layers. In many of these retaining structures, footings are located on the backfill and over the soil (e.g. footings on bridge abutments or roads located on top of the retaining structure). Despite …

    ghent Repository record for Geosynthetic-reinforced soil retaining walls subjected to surcharge loads (opens in a new tab)

  13. Rutting Performance of Airport Hot-Mix Asphalt Characterized by Laboratory Performance Testing, Full-Scale Accelerated Pavement Testing, and Finite Element Modeling

    … of results from four potential laboratory tests, (b) comparisons of laboratory tests results to full-scale accelerated pavement test results, and (c) analyses of results from finite element simulations. The laboratory study evaluated of the repeated load test, the static creep test, the …

    tamu Repository record for Rutting Performance of Airport Hot-Mix Asphalt Characterized by Laboratory Performance Testing, Full-Scale Accelerated Pavement Testing, and Finite Element Modeling (opens in a new tab)

  14. Plastic interaction relations for hollow structural steel sections.

    … an experimental program consisting of six full-scale tests on pipe sections under load combinations of shearing forces, bending moments, and twisting moments. The experimental results agree very well with the predicted failure loads based on recently developed interaction relations. The …

    ottawa-retro Repository record for Plastic interaction relations for hollow structural steel sections. (opens in a new tab)

  15. Alternative Dynamic Testing by Active Control

    … for experimental validation of designs with full-scale tests (e.g. shake table and pseudo dynamic testing) can be extremely expensive and the facilities necessary are not available at many universities. This thesis proposes an Alternative Dynamic Test which uses a properly scaled model test …

    maryland Repository record for Alternative Dynamic Testing by Active Control (opens in a new tab)

  16. The prediction of moment-rotation curves of extended endplate connections for use in semi-rigid analysis of steel frameworks

    … for these analyses is by conducting expensive full-scale testing of connection subassemblies. There is a need for methods of prediction for all types of steel framework connections. In this study a method of predicting the behaviour of extended endplate connections has been presented. …

    city-london Download PDF for The prediction of moment-rotation curves of extended endplate connections for use in semi-rigid analysis of steel frameworks (opens in a new tab)

  17. Uplift loaded standing seam roof systems

    … standing seam roof system. Four sets of full-scale tests were conducted and their results were analyzed along with previous results (Anderson 1991). It was found that by normalizing the data, a reduction factor could be established for each test set configuration. This reduction factor …

    vt Repository record for Uplift loaded standing seam roof systems (opens in a new tab)

  18. Influência da temperatura e da sequência de empilhamento de camadas na resistência à pressão externa de dutos de compósitos

    … is done safely. In this way, a series of small-scale characterization tests were conducted on typical composites for this application, and their results were used to calibrate some failure criteria from the literature. Then, these criteria were applied to numerical models representing pipes …

    brazil-uerj Repository record for Influência da temperatura e da sequência de empilhamento de camadas na resistência à pressão externa de dutos de compósitos (opens in a new tab)

  19. Behaviour of unstiffened column webs in bolted beam-to-column connections in building frames

    … column web failure moments based on a series of full scale tests (flush and extend end plates) carried out at the University of Abertay Dundee.<br/>Buckling of the column web was observed in a large number of the bolted beam-to-column connections tested.<br/>Three dimensional finite element …

    abertay Repository record for Behaviour of unstiffened column webs in bolted beam-to-column connections in building frames (opens in a new tab) Download PDF for Behaviour of unstiffened column webs in bolted beam-to-column connections in building frames (opens in a new tab)

Page 1 of 7