Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 64 for “"Fundus camera"”.
-
Novel Fundus Camera Design
A fundus camera a complex optical system that makes use of the principle of reflex free indirect ophthalmoscopy to image the retina. Despite being in existence as early as 1900's, little has changed in the design of a fundus camera and there is minimal information about the design principles …
-
Developing a Wi-Fi Controlled Portable and Low-Cost Telehealth Fundus Camera
… leading cause of blindness in adults. Access to fundus cameras is essential to detecting diabetic retinopathy at an early curable stage. Most commercially available specialized fundus cameras cost thousands of dollars and as a result, are inaccessible to patients in rural areas and third-world …
-
Ocular Distortion Measurement and Relationship with Refractive Error
… tested in a sample population. Using a modified fundus camera, a target is projected onto the retinal surface and imaged to a detector. A distortion criterion for a rotationally non-symmetric optical system is used to analyze the resulting distortion pattern. A simulated population of one …
-
Spectral reflectance of the normal and abnormal human fundus oculi
Studies of the fundus oculi with light of restricted spectrum are not new. The object of this investigation is to evaluate the usefulness of monochromatic light in differentiating between various structures, both normal and abnormal, in the human fundus oculi. Previous work is reviewed and the …
-
Portable Devices for Diagnosis of Glaucoma in Community Health Care Settings in Nigeria
… PEEK Acuity, iCare Tonometer, Remidio handheld fundus camera, and Eyecatcher Visual Field Analyser were evaluated against standard hospital equipment (LogMAR, Goldmann Applanation Tonometer, slit lamp, Humphrey Field Analyser) for diagnostic performance. • Phase II – Community Feasibility Study: …
-
Snapshot Imaging Polarimeters Using Spatial Modulation
… we incorporate a Savart Plate polarimter into a fundus camera to measure the human eye's retinal retardance, useful information for glaucoma diagnosis. Thirdly, a world-smallest imaging polarimeter is proposed and demonstrated, which may open many applications in security, remote sensing and …
-
Automated static perimetry and dimensional characteristics of the intra- and peri-papillary retinal features in myopia
… with peripapillary crescents and tigroid fundus changes only. The appearance of the optic nerve head and surrounding structures were used to classify subjects into groups for the analysis of field data. In addition, the dimensions of features of the optic nerve head and peripapillary …
-
Reflex Free Fundus Imaging of Wide Field of Views through Small Pupils using DMD Projector Illumination
Fundus cameras illuminate and view the retina through the eye pupil. Reflections and haze from the eye and the lenses in the common detection and illumination path obscure the image and limit the field of view and minimum pupil size. Pupil splitting was first demonstrated by Allvar Gullstrand in …
-
Design of ophthalmic equipment for low-income countries : a workflow perspective
… to design a tablet-computer operated, portable fundus camera for screening of preterm infants.;The results suggest that several mHealth design parameters have optimal values at odds with many of the piloted technologies that have failed to achieve adoption within the respective scenarios. It is …
-
Advancing Medical Diagnostics: A Comprehensive Study of Fundus Image Analysis Techniques
… has important clinical and research value. Fundus images, obtained by a fundus camera, are crucial for diagnosing fundus diseases such as diabetes, hypertension, macular degeneration, and fundus arteries. This dissertation focuses on fundus image acquisition, preprocessing, blood vessel …
-
Modeling, Pattern Analysis and Feature-Based Retrieval on Retinal Images
Inexpensive high quality fundus camera systems enable imaging of retina for vision related health management and diagnosis at large scale. A computer based analysis system can help establish the general baseline of normal conditions vs. anomalous ones, so that different classes of retinal …
-
Novel Stem Cell-based Retinal Transplant and Swine Model of Retina Degeneration: Enabling Technologies for Regenerative Therapies
… by indirect ophthalmoscope evaluation (i.e., fundus camera imaging, SD-OCT, ICGA, and FA). Results. We have established a novel 3DNR/RPE complex that recreates the cellular composition and organization of the native outer retina, including the physical and functional association between the …
-
Investigating retinal microvasculature and morphological health and its relation to brain health during and after COVID-19 recovery
… was conducted to determine the utility of fundus imaging as a non-invasive, inexpensive, accessible tool for measuring retinal microvascular health and its relationship to markers of neurovascular health in individuals with and without persistent COVID. It explores the relationships between …
-
A novel Automatic Optic Disc and Cup Image Segmentation System for Diagnosing Glaucoma using RIGA dataset
… the retina is a very important landmark of the fundus and is altered in optic nerve pathology especially glaucoma. Numerous imaging systems are available to capture the retinal fundus and from which some structural parameters can be inferred the retinal fundus camera is one of the most important …
-
Vergleich der Ergebnisse einer standardisierten augenärztlichen Untersuchung mit den Ergebnissen einer mobilen Kamera
… Untersuchung mit einer mobilen Kamera (Aurora-Funduskamera von Optomed) gestellt wurden. Die Sensitivität, Spezifität sowie der positive und negative Vorhersagewert und die Accuracy der Kamera verglichen mit dem Referenzstandard der binokularen Untersuchung in Mydriasis and der Spaltlampe mit …
-
Αγγειοειδείς ταινίες: επιπλοκές - θεραπεία
… ocular examination including contact lens fundus biomicroscopy, color or red-free fundus photography, and digital fluorescein angiography (FA) using the Topcon Imagenet 2000 Digital Imaging System with TRC-50IA fundus camera (Topcon Corporation, Paramus, New Jersey, USA). Fluorescein …
-
Characterising the role of Choroidal Inflammation in Retinal Diseases
… donor tissues for the study of the pathologies. Fundus camera and optical coherence tomography (OCT) imaging system were used to obtain images of the posterior segment in the ex vivo human eye. Typical ocular lesions were haemorrhages, drusen, and pigment deposits. The lesions were confirmed …
-
Solutions to the unseen domain problem for machine learning-based glaucoma detection from retinal fundus images
… detection and treatment of eye diseases. Retinal fundus images are helpful for glaucoma screening. However, the existing glaucoma identification systems trained using images from a specific camera fail to perform well with those captured from a new camera. This research aims to find solutions to …
Page 1 of 4