Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 6791 for “"GC"”.

  1. GC×GC-MS and parallel 2DLC-MS based untargeted metabolomics.

    … gas chromatography mass spectrometry (GC×GC-MS) has been used in different scientific fields, its use in untargeted metabolomics is limited due to several challenges, such as complicated data analysis and limited accuracy of metabolite identification. Two-dimensional liquid …

    louisville Repository record for GC×GC-MS and parallel 2DLC-MS based untargeted metabolomics. (opens in a new tab)

  2. Analysis of Biogenic Amines by GC/FID and GC/MS

    … are difficult to analyze by Gas Chromatography (GC) due to their lack of volatility and their interaction with the GC column, often leading to significant tailing and poor reproducibility. Biogenic amines need to be derivatized before both GC and HPLC analyses. The objective of this research was …

    vt Repository record for Analysis of Biogenic Amines by GC/FID and GC/MS (opens in a new tab)

  3. Application of GC×GC-MS in VOC analysis of fermented beverages

    GC×GC is an efficient tool for the analysis of volatile compound. However, improvements are still required on VOC extraction, GC×GC setup and data processing. Different sample preparation techniques and GC×GC setup were compared based on the literature study and experimental results. Each VOC …

    trento Repository record for Application of GC×GC-MS in VOC analysis of fermented beverages (opens in a new tab)

  4. Temperature Programming of the Second Dimension in Comprehensive Two-Dimensional Gas Chromatography (GC×GC)

    Comprehensive two-dimensional gas chromatography (GC×GC) is a mature separation technique that is now over three decades old. It separates all sample components using two GC columns with different selectivities, connected in series through a special interface called a modulator to provide two …

    waterloo Repository record for Temperature Programming of the Second Dimension in Comprehensive Two-Dimensional Gas Chromatography (GC×GC) (opens in a new tab)

  5. Development of a Single-Stage Modulator for Comprehensive Two-Dimensional Gas Chromatography (GC × GC)

    … (TAG) system. However, as conventional GC does not provide adequate separation power, the development of comprehensive two-dimensional gas chromatography (GC × GC) was required. GC × GC works more effectively by utilizing a modulator that periodically traps and focuses analytes from a …

    waterloo Repository record for Development of a Single-Stage Modulator for Comprehensive Two-Dimensional Gas Chromatography (GC × GC) (opens in a new tab)

  6. Chemometric Comparison Of GC-MS And GC-VUV For The Trace Analysis Of Methamphetamine

    … both on a gas chromatograph- mass spectrometer (GC-MS) and a gas chromatograph- vacuum ultraviolet spectrometer (GC-VUV). The raw GC-MS and GC-VUV data were separately normalized, and the dimensionality of the data was reduced through PCA, which uses orthogonal linear transformations of the data …

    iupui Repository record for Chemometric Comparison Of GC-MS And GC-VUV For The Trace Analysis Of Methamphetamine (opens in a new tab)

  7. Advanced Theoretical Modeling Approaches and Innovative Data Processing Workflows in GC×GC-ToF-MS

    … chromatography coupled with mass spectrometry (GC×GC-MS) is nowadays widely recognized as an indispensable analytical method across multiple research fields. The research presented in this thesis aims to comprehensively understand GC×GC-MS by addressing both method development and data …

    liege Repository record for Advanced Theoretical Modeling Approaches and Innovative Data Processing Workflows in GC×GC-ToF-MS (opens in a new tab) Restricted access

  8. Field Analysis of Total PCBs in Soils by Thermal Desorption/GC and Determination of the Individual PCB Congeners by GC X GC - TOF-MS

    … the time of investigation. Gas chromatography (GC), a widespread technique for the determination of organic pollutants in the environment, has also shown to be useful in environmental field analysis. Thermal desorption of solid environmental sample provides a technique for liberation of volatile …

    waterloo Repository record for Field Analysis of Total PCBs in Soils by Thermal Desorption/GC and Determination of the Individual PCB Congeners by GC X GC - TOF-MS (opens in a new tab)

  9. Μελέτη των πτητικών ενώσεων Ελληνικών οίνων με τεχνικές αέριας χρωματογραφίας, GC/MS και GC-FID

    Ο οίνος αποτελεί ένα αλκοολούχο ποτό ιδιαίτερου ενδιαφέροντος, πολύ δημοφιλές σε όλες τις χώρες του κόσμου. Καταναλώνεται παγκοσμίως σε μεγάλες ποσότητες και συνοδεύει ευρύ φάσμα ευρωπαϊκών και μεσογειακών γαστρονομικών απολαύσεων. Στην Ελλάδα η οινοπαραγωγή ανάγεται στην αρχαιότητα, έχει εξελιχθεί …

    athens Repository record for Μελέτη των πτητικών ενώσεων Ελληνικών οίνων με τεχνικές αέριας χρωματογραφίας, GC/MS και GC-FID (opens in a new tab)

  10. Fundamental studies of Rocket propellant fuel using GC × GC - TOFMS instrumentation with chemometric data analysis

    … studies of Rocket propellant fuel using GC &times GC &mdash TOFMS instrumentation with chemometric data analysis. Benjamin Kehimkar Chair of the Supervisory Committee: Professor Robert E. Synovec Department of Chemistry For most of the research presented herein, samples of complex …

    washington Repository record for Fundamental studies of Rocket propellant fuel using GC × GC - TOFMS instrumentation with chemometric data analysis (opens in a new tab)

  11. Breathomics for Clinical Pulmonology: Advancing a TD-GC×GC-MS Platform Toward Direct Clinical Implementation

    … gas chromatography mass spectrometry (TD-GC×GC-MS) platform. The three offline sampling devices in widest use were first compared within the peppermint benchmarking protocol. No device proved universally optimal. Tedlar® bags showed the lowest overall variability (mean pooled RSD 54%) but …

    liege Repository record for Breathomics for Clinical Pulmonology: Advancing a TD-GC×GC-MS Platform Toward Direct Clinical Implementation (opens in a new tab) Embargoed

  12. Βελτιστοποίηση και επικύρωση μεθόδου για τον έλεγχο ντοπιγκ απαγορευμένων ουσιών με gc/hrms και gc/ms

    … συζευγμένης με φασματομετρία μαζών (GC/MS και GC/HRMS) χρησιμοποιώντας τη σάρωση επιλεγμένων ιόντων ώστε να καταγράφεται ένα χαρακτηριστικό ιόν για κάθε έναν από τους αναλύτες. Οι παράμετροι αξιολόγησης που εξετάστηκαν είναι τα χρωματογραφικά χαρακτηριστικά, η ειδικότητα, έλεγχος …

    athens Repository record for Βελτιστοποίηση και επικύρωση μεθόδου για τον έλεγχο ντοπιγκ απαγορευμένων ουσιών με gc/hrms και gc/ms (opens in a new tab)

  13. Využití GC/MS při analýze léčiv

    … spektrometrickou detekcí Time-of-Flight (GC/TOF-MS).

    brno-tech Repository record for Využití GC/MS při analýze léčiv (opens in a new tab)

  14. Elucidating Regulatory Events Along GC-1

    Guanylyl Cyclase-1 (GC-1), or soluble guanylyl cyclase (sGC), is a heterodimeric heme-containing protein that responds to the binding of nitric oxide (NO) with enhanced cyclase activity, producing cyclic guanosine monophosphate (cGMP) and a signaling cascade. NO regulates numerous physiological …

    arizona-thes Repository record for Elucidating Regulatory Events Along GC-1 (opens in a new tab)

  15. Fast GC: Applications and Theoretical Studies

    … of fast temperature programming in the fast GC analyses of various sample types. These samples included polycyclic aromatic hydrocarbons (PAHs), hydrocarbons and food samples. Programming rates of up to 1200° C/min were used. These fast programming rates were obtained by using "flash"â ¢ …

    vt Repository record for Fast GC: Applications and Theoretical Studies (opens in a new tab)

  16. Development of a Cost-Effective and Consumable-Free Interface for Comprehensive Two-Dimensional Gas Chromatography (GC×GC)

    … limitation to conventional gas chromatography (GC) is limited peak capacity, making the analysis of complex mixtures a difficult or even impossible task. Comprehensive two-dimensional gas chromatography (GC×GC) significantly increases peak capacity and resolution, improves sensitivity and …

    waterloo Repository record for Development of a Cost-Effective and Consumable-Free Interface for Comprehensive Two-Dimensional Gas Chromatography (GC×GC) (opens in a new tab)

  17. The Role of Post-Translational Modifications and Allostery in the Receptor Guanylyl Cyclases GC-A and GC-B

    The receptor guanylyl cyclases (GC) GC-A and GC-B are complex transmembrane proteins with multiple functional domains and multiple post-translational modifications. GC-A and GC-B are activated by selective natriuretic peptide (NP) hormones binding to their glycosylated extracellular domains and …

    umn Repository record for The Role of Post-Translational Modifications and Allostery in the Receptor Guanylyl Cyclases GC-A and GC-B (opens in a new tab)

Page 1 of 340