Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 27 for “"GC-iRMS"”

  1. Development and Application of An Integrated GC-MS/MS and GC-IRMS Analytical Approach in Food Quality Evaluation

    … coupled with tandem mass spectrometry (GC-MS/MS) is widely used for the analysis of VOCs in plant extracts and essential oils. This highly sensitive and selective technique enables detailed compositional profiling of complex botanical matrices. Through chromatographic separation and mass …

    trento Repository record for Development and Application of An Integrated GC-MS/MS and GC-IRMS Analytical Approach in Food Quality Evaluation (opens in a new tab) Embargoed

  2. Biomarqueurs isotopomiques en 13C par RMN et GC-IRMS d’acides gras des produits laitiers : élucidation de voies métaboliques et applications alimentaires

    … Au cours de la thèse, une nouvelle méthode par GC-IRMS a permis de mesurer avec précision les rapports isotopiques du 13C dans les acides gras séparés et en particulier les acides gras à courte chaîne (C4 à C12), non observés jusqu’à présent. Une méthodologie utilisant la RMN 13C quantitative a …

    star-france Repository record for Biomarqueurs isotopomiques en 13C par RMN et GC-IRMS d’acides gras des produits laitiers : élucidation de voies métaboliques et applications alimentaires (opens in a new tab)

  3. Adaptación de la dilución isotópica en línea de carbono a equipos de GC-IRMS como sistema genérico de cuantificación de compuestos orgánicos sin la necesidad de patrones específicos

    … metodología se empleó un instrumento comercial GC-MS de tipo cuadrupolo, sobre el que se realizaron tres modificaciones: (i) una interfase de combustión para la conversión cuantitativa de los analitos a CO2, (ii) un sistema para la adición de un flujo constante de trazador, y (iii) una válvula …

    oviedo Repository record for Adaptación de la dilución isotópica en línea de carbono a equipos de GC-IRMS como sistema genérico de cuantificación de compuestos orgánicos sin la necesidad de patrones específicos (opens in a new tab)

  4. The development of an in-situ UV ablation GC-irms technique for the analysis of oxygen isotopes in metamorphic minerals, and its application to polymetamorphic schists from Western Massachusetts, U.S.A

    <p>This thesis describes an attempt to develop a pioneering method for the analysis of oxygen isotopes in metamorphic rocks. This technique is then applied to a suite of metapelites from Massachusetts, U.S.A. with the aim of investigating metamorphic history.</p> <p>The study of oxygen isotopes is …

    oxford Repository record for The development of an in-situ UV ablation GC-irms technique for the analysis of oxygen isotopes in metamorphic minerals, and its application to polymetamorphic schists from Western Massachusetts, U.S.A (opens in a new tab)

  5. Measurement of glutathione synthesis by isotope ratio mass spectrometry in systemic inflammation

    … using both gas chromatography-mass spectrometry (GC-MS) and gas chromatography-isotope ratio mass spectrometry (GC-IRMS) was developed. The derivatives of both compounds were measured in a single chromatographic analysis, and the method was compatible with both GC-MS and GC-IRMS, and capable of …

    ucl Repository record for Measurement of glutathione synthesis by isotope ratio mass spectrometry in systemic inflammation (opens in a new tab)

  6. Stable carbon isotope ratio of polycyclic aromatic hydrocarbons (PAHs) in the environment: validation of isolation and stable carbon isotope analysis methods

    … purities after purification were verified by GC/FID and full scan mass spectrometry. To better resolve peaks and provide more accurate stable carbon isotope measurements, various gas chromatographic conditions were evaluated. The precision of the method ranged between 0.08 and 0.43 . The …

    tamu Repository record for Stable carbon isotope ratio of polycyclic aromatic hydrocarbons (PAHs) in the environment: validation of isolation and stable carbon isotope analysis methods (opens in a new tab)

  7. Compound Specific Isotope Ratio Analysis in Vapour Intrusion Studies using Waterloo Membrane Sampler (WMS)

    … ratio mass spectrometry system (TD-GC-IRMS). The TD-GC-IRMS was employed to determine the stable carbon isotopic composition (δ13C) of three model analytes: hexane, benzene and trichloroethylene, which were contained in a standard gas mixture. In order to determine whether isotopic …

    waterloo Repository record for Compound Specific Isotope Ratio Analysis in Vapour Intrusion Studies using Waterloo Membrane Sampler (WMS) (opens in a new tab)

  8. Biosynthèse des unités isopréniques chez les végétaux

    … biosynthétique d’isoprénoïdes de végétaux par GC-iRMS, une intéressante alternative aux expériences de marquage. Nous avons comparé les signatures isotopiques δD et δ13C des lipides provenant de huit organismes phototrophes et formulé plusieurs hypothèses permettant d’expliquer les différences …

    star-france Repository record for Biosynthèse des unités isopréniques chez les végétaux (opens in a new tab) Restricted access

  9. Stable carbon isotope characterization of nonmethane hydrocarbons in Vancouver and Toronto airsheds

    … Chromotograph-Isotope Ratio Mass Spectrometry (GC-IRMS). In the Greater Toronto Area, the average isotope ratio of all ambient measurements of NMHC, including halogenate NMHC was found to be -25.7 + 3.4 %o. Traffics related source sites in the Greater Toronto Area have an average isotope ratio …

    uvic Repository record for Stable carbon isotope characterization of nonmethane hydrocarbons in Vancouver and Toronto airsheds (opens in a new tab)

  10. Ανάπτυξη μεθόδων για την ανάλυση εκρηκτικών υλών και παραγώγων αυτών

    … using Gas Chromatography–Mass Spectrometry (GC–MS). The development of this method offers a solution to the forensics laboratories regarding the persistent identification problem of this macromolecule. Moreover, in the second part of the thesis, a characteristic derivative of SCN- coming from …

    greece Repository record for Ανάπτυξη μεθόδων για την ανάλυση εκρηκτικών υλών και παραγώγων αυτών (opens in a new tab)

  11. Biological effect of temperature changes on microbial communities and groundwater contaminations

    … – isotope ratio mass spectrophotometer (GC–IRMS)) and molecular community profiling were used to quantify acetate and toluene mineralisation under sulfate-reducing conditions and to identify the key organisms involved. Degradation of trichloroethene (TCE) was monitored by gas …

    cau-kiel Repository record for Biological effect of temperature changes on microbial communities and groundwater contaminations (opens in a new tab)

  12. Dyzelino ir benzino iš Vilniaus degalinių anglies izotopinio santykio verčių matavimai bei frakcionacijos dydžio nustatymas /

    … isotope ratio (δ13C) was measured using EA – IRMS and GC – IRMS systems. The isotopic analysis of fuels revealed that δ(_^13)C values of gasoline and diesel are respectively -29,96±0,19‰ and -30,77±0,13‰. The negligeble variation of the results around the mean values indicate that all the …

    vilnius Repository record for Dyzelino ir benzino iš Vilniaus degalinių anglies izotopinio santykio verčių matavimai bei frakcionacijos dydžio nustatymas / (opens in a new tab)

  13. Development and Application of a GG-IRMS Reductive Pyrolysis Reactor Interface for the δ<sup>34</sup>S Determination of Sulfur in Individual Organic Compounds

    … exists for C,H,and N. To that end, a new GC-IRMS reductive pyrolysis reactor interface was developed for the σ34S determination of low-molecular weight organo-sulfur compounds. Modification to the existing GC-combustion-IRMS instrument consisted of changing the reactor catalyst, …

    odu Repository record for Development and Application of a GG-IRMS Reductive Pyrolysis Reactor Interface for the δ<sup>34</sup>S Determination of Sulfur in Individual Organic Compounds (opens in a new tab)

  14. Concentration and isotopic composition of marine nitrous oxide, in particular the oxygen-17 isotope excess

    … Chromatography-Isotope Ratio Mass Spectrometry (GC-IRMS) analytical system for δ(15N), δ(18O) and Δ(17O) of N2O. Δ(17O) values between 0.1 and 4.6 ‰ (relative to VSMOW) were observed during three field campaigns in the temperate, subtropical and tropical Atlantic Ocean, the Scotia Sea and the …

    east-anglia Repository record for Concentration and isotopic composition of marine nitrous oxide, in particular the oxygen-17 isotope excess (opens in a new tab)

  15. Compound-Specific Isotope Records of Dust Provenance and Hydroclimate in the North Pacific and Marginal Seas of East Asia: Integrating n-Alkane δ13C and δD with Standardized Analytical Frameworks

    … Normalization for CSIA), a MATLAB toolkit for GC-IRMS data processing with improved drift correction, scale normalization, and uncertainty propagation. SINC enhances data comparability and interpretability for robust paleoenvironmental reconstructions. These geochemical records provide new …

    lsu-thes Repository record for Compound-Specific Isotope Records of Dust Provenance and Hydroclimate in the North Pacific and Marginal Seas of East Asia: Integrating n-Alkane δ13C and δD with Standardized Analytical Frameworks (opens in a new tab)

  16. Chemical and Stable Isotopic Characterization of Geofluids from an Unconventional Natural Gas Field in New Brunswick, Canada

    … samples were determined by gas chromatography (GC) and gas-chromatography isotope-ratio-mass-spectroscopy (GC-IRMS), and compositions of the water samples were determined by inductively-coupled-plasma mass spectroscopy (ICP-MS), optical-emission spectroscopy (ICP-OES), and isotope-ratio mass …

    ottawa-retro Repository record for Chemical and Stable Isotopic Characterization of Geofluids from an Unconventional Natural Gas Field in New Brunswick, Canada (opens in a new tab)

  17. Using the 13C/12C Ratio of Bacteria-Specific Fatty Acids to Determine the Lability of Terrestrial and Marine Organic Matter in Coastal Sediments

    … coupled to an isotope ratio mass-spectrometer (GC-IRMS). Ubiquitous bacteria strains responsible for the degradation of OM were cultivated in marine broth enriched in 13C with 13C-sodium acetate to assess the relationship and isotopic fractionation between the 13C signature of the food source …

    concordia

  18. Stable isotope analysis: a new forensic science tool

    … technique isotope ratio mass spectrometry (IRMS) has increased the information obtainable regarding sample origin and history.<br/><br/>Investigations were carried out on white paint samples using Elemental Analysis Isotope Ratio Mass Spectrometry (EA-IRMS) to determine the discriminatory …

    qu-belfast Repository record for Stable isotope analysis: a new forensic science tool (opens in a new tab)

  19. Organic matter preservation in marine sediments : a bulk and molecular study

    … Further molecular, compound-specific isotopic (GC-IRMS) and spectroscopic (FTIR, solid-state HR-NMR) studies on the OSOM component will help verifying the hypothesis of the major role of oxygen exposure time in OM preservation.

    concordia

  20. Isotope Ratio Mass Spectrometry - A Rapidly Developing Tool for Forensic Samples

    … samples is described. A gas chromatograph (GC) was coupled to an isotope ratio mass spectrometer (IRMS) in parallel with a single quadrupole mass spectrometer (MS). The modification was achieved by using a low, dead volume x-connector to split the effluent coming from the column so that …

    ohiolink Repository record for Isotope Ratio Mass Spectrometry - A Rapidly Developing Tool for Forensic Samples (opens in a new tab)