Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 130 for “"GOx"”.

  1. Plume Contamination Measurements of an Additively-Printed GOX/ABS Hybrid Thruster

    … on optical surfaces of spacecraft by an ABS/GOX thruster. Plume contamination presents a significant operational hazard for spacecraft solar arrays and thermal control surfaces can lead to decreased power production and increased spacecraft temperatures. Historically, due to the lack of a …

    utahstate Repository record for Plume Contamination Measurements of an Additively-Printed GOX/ABS Hybrid Thruster (opens in a new tab)

  2. Axisymmetric Air Augmented Methanol/Gox Rocket Mixing Duct Experimental Thrust Study

    A hot-flow axisymmetric Air Augmented Rocket (AAR) test apparatus was constructed to test various mixing duct configurations at static conditions. Primary flow for the AAR was provided through a liquid methanol-gaseous oxygen bipropellant rocket. Experimental thrust measurements were recorded and …

    calpoly Repository record for Axisymmetric Air Augmented Methanol/Gox Rocket Mixing Duct Experimental Thrust Study (opens in a new tab)

  3. Throttleable GOX/ABS Launch Assist Hybrid Rocket Motor for Small Scale Air Launch Platform

    The ability for an aircraft-based launch platform to place an orbital payload onto a nominal launch trajectory at a higher energy state -- altitude, velocity, flight path angle, and azimuth --using highly-efficient air breathing propulsion instead of a much lower-efficiency rocket system, offers …

    utahstate Repository record for Throttleable GOX/ABS Launch Assist Hybrid Rocket Motor for Small Scale Air Launch Platform (opens in a new tab)

  4. The use of austenitic stainless steel versus monel (Ni-Cu) alloy in pressurized gaseous oxygen (GOX) life support systems.

    Gaseous oxygen (GOX) must be stored at pressures up to 24 MPa (3500 psi) to provide the flow rates required to support the metabolic needs of a diver. A review of the literature concerned with materials compatibility in pressurized oxygen systems was conducted, with emphasis on metallic structural …

    nps Repository record for The use of austenitic stainless steel versus monel (Ni-Cu) alloy in pressurized gaseous oxygen (GOX) life support systems. (opens in a new tab)

  5. Neorganinių druskų ir paviršiaus aktyviųjų medžiagų poveikis gliukozės oksidazės deagregacijai ir bioaktyvumo atstatymui /

    Glucose oxidase (GOx) is a widely used enzyme whose activity depends on the structural state of the protein and the accessibility of its active site to the substrate. Protein aggregation can reduce enzymatic activity, so it is important to assess whether the aggregated enzyme can be at least …

    vilnius Repository record for Neorganinių druskų ir paviršiaus aktyviųjų medžiagų poveikis gliukozės oksidazės deagregacijai ir bioaktyvumo atstatymui / (opens in a new tab)

  6. Enzyme-Initiated Admicellar Polymerization

    … we studied the use of glucose oxidase (GOx) in admicellar polymerization. In this method, GOx acts as the catalyst in the oxidation of ?-D-glucose, while consuming oxygen and generating hydrogen peroxide and D-glucono-?-lactone. There are many advantages of GOx to other deoxygenation …

    mississippi Repository record for Enzyme-Initiated Admicellar Polymerization (opens in a new tab)

  7. Gliukozės oksidazės spektroskopinių savybių ir aktyvumo tyrimai /

    … active part of the biosensor is glucose oxidase (GOx) enzyme immobilized on the surface of the electrode. During enzymatic reaction electrons are transferred from glucose to the surface of the electrode. But In order to create exact biosensor, we need to understand properties of this enzyme in …

    vilnius Repository record for Gliukozės oksidazės spektroskopinių savybių ir aktyvumo tyrimai / (opens in a new tab)

  8. Gliukozės oksidazės imobilizuotos į polipirolą fluorescencijos gesimas /

    … active part of the biosensor is glucose oxidase (GOx) enzyme immobilized on the surface of the electrode. The conducting polymers are used as a matrix for immobilization that facilitates electrons transfer from enzyme to electrically conductive surface of the electrode. When constructing …

    vilnius Repository record for Gliukozės oksidazės imobilizuotos į polipirolą fluorescencijos gesimas / (opens in a new tab)

  9. Enzyme-immobilized hydrogels to create hypoxia for in vitro cancer cell culture

    … of this thesis was to modify glucose oxidase (GOX) for copolymerization with poly(ethylene glycol)-diacrylate (PEGDA) to form GOX-immobilized PEG-based hydrogels. The effect of soluble GOX or acrylated GOX on sustaining hypoxia was evaluated under ambient air condition (i.e., with constant …

    iupui Repository record for Enzyme-immobilized hydrogels to create hypoxia for in vitro cancer cell culture (opens in a new tab)

  10. Attaching proteins on modified silicon surfaces

    … The immobilization of glucose oxidase (GOX) onto amino-terminated Si (111) has been investigated combined XPS and AFM studies. AFM images revealed that it is suitable for immobilizing GOX employing cross-linking reaction. GOX molecules form rings like clusters in the first monolayer at …

    nus Repository record for Attaching proteins on modified silicon surfaces (opens in a new tab) Download file for Attaching proteins on modified silicon surfaces (opens in a new tab)

  11. The Characterization and Optimization of an IrOx-based Glucose Biosensor

    … oxide (IrOx) nanoparticle (NP)/glucose oxidase (GOx) based glucose biosensor, with the goal of achieving an accurate and reproducible O2-independent glucose response. Two approaches were used for the fabrication of this IrOx-based glucose sensor. In the first, a sensing ink consisting of three …

    calgary Repository record for The Characterization and Optimization of an IrOx-based Glucose Biosensor (opens in a new tab)

  12. Über die Denaturierungstemperatur des Enzyms Glukoseoxidase als Mass seiner Funktionsstabilität sowie ihre nano-kalorimetrische Bestimmung

    … des Enzyms Glukoseoxidase (GOx) hat. <br>Ein Chip-Kalorimeter mit Widerstandsthermometern aus amorphem Germanium wurde entwickelt und seine Eignung zur Bestimmung der Tm von GOx demonstriert.

    freiburg-diss Repository record for Über die Denaturierungstemperatur des Enzyms Glukoseoxidase als Mass seiner Funktionsstabilität sowie ihre nano-kalorimetrische Bestimmung (opens in a new tab)

  13. Electrochemical immunosensors

    … applied for the detection of glucose oxidase (GOx). The sensing mechanism depends on the blocking of alumina pore channels when the antigen molecules bind to antibody molecules attached to the channel walls, impeding the diffusion of redox probe, ferrocenemethanol, towards the sensing platinum …

    nus Repository record for Electrochemical immunosensors (opens in a new tab) Download file for Electrochemical immunosensors (opens in a new tab)

  14. Enzymatic and non-enzymatic bioanodes: novel materials for glucose oxidase and polyviologen biosensors and biofuel cells

    … the interaction of iodide and glucose oxidase (GOx) was carried out, showing that the iodide acts as a direct mediator with GOx in enzymatic glucose biosensors. This direct mediation may be happening in parallel with the known electron transport chain through hydrogen peroxide. The aqueous …

    oklahoma-thes Repository record for Enzymatic and non-enzymatic bioanodes: novel materials for glucose oxidase and polyviologen biosensors and biofuel cells (opens in a new tab) Restricted access

  15. Adsorption-Induced Changes in Enzyme Bioactivity Correlated with Adsorbed Protein Orientation and Conformation

    … xylanase (XYL; 21.3 kDa), and glucose oxidase (GOx; 160 kDa)] on OH-, CH3-, NH2-, and COOH-terminated alkanethiol self-assembled monolayer (SAM) surfaces. The bioactivities of the small proteins, TRP, HEWL, and XYL, had pronounced variations between the different SAM surfaces despite their …

    clemson Repository record for Adsorption-Induced Changes in Enzyme Bioactivity Correlated with Adsorbed Protein Orientation and Conformation (opens in a new tab)

  16. Fermentinio gliukozės biojutiklio aptikimo elementų tyrimas /

    … (GluOx_B), both using glucose oxidase (GOx) as the biological recognition element. The GluOx_A biosensor incorporated GOx, horseradish peroxidase (HRP) modified with ferrocene, while the GluOx_B biosensor used only GOx and relied on oxygen reduction at the electrode surface. Analytical …

    vilnius Repository record for Fermentinio gliukozės biojutiklio aptikimo elementų tyrimas / (opens in a new tab)

  17. Avaliação de enzimas microbianas para tratamento e adequação de farinhas de trigo em substituição ao uso de oxidantes químicos : efeitos sobre as propriedades reológicas de dois perfis de farinha

    … (XYL-F) e bacteriana (XYL-B), glucose oxidase (GOX), lacase (LAC), lipase (LIP) e transglutaminase (TG) foram testadas em dois tipos de farinha: uma farinha forte padrão (farinha A) e uma farinha fraca comum (farinha B). Inicialmente, as enzimas foram adicionadas individualmente na farinha onde, …

    brazil-ufrgs Repository record for Avaliação de enzimas microbianas para tratamento e adequação de farinhas de trigo em substituição ao uso de oxidantes químicos : efeitos sobre as propriedades reológicas de dois perfis de farinha (opens in a new tab)

  18. Influence of pharmaceutical materials on the sensitivity of prussian blue-based sensors /

    … CV on FTO. It was followed by the dispersion of GOX on the glass/FTO/PB. After the dispersion of enzyme, it was cross linked with 25% glutaraldehyde solution and glass/FTO/PB/GOX biosensor was constructed. In this research project four substances along with glucose were examined to see their …

    vilnius Repository record for Influence of pharmaceutical materials on the sensitivity of prussian blue-based sensors / (opens in a new tab)

  19. Gliukozės oksidazės ir mioglobino biokonjugacija elektrochemiškai aktyviomis grupėmis ir taikymas bioelektronikoje /

    … bioconjugation of two proteins, glucose oxidase (GOx) and myoglobin (Myo), with different electrochemically active groups to enhance their self-assembly. Myo, a small haem-containing protein, is capable of direct electrode transfer between the protein and the electrode surface. GOx, a reliable, …

    vilnius Repository record for Gliukozės oksidazės ir mioglobino biokonjugacija elektrochemiškai aktyviomis grupėmis ir taikymas bioelektronikoje / (opens in a new tab)

  20. Electrochemical Characterization of Photocurable and Layer-By-Layer Assembled Ferrocene-Modified Linear Poly(ethylenimine) Bioelectrodes

    … crosslinked in the presence of glucose oxidase (GOX) using both photogenerated radicals and nitrenes. Biosensor efficiency was found to be a function of both polymer connectivity and enzyme stability. Fc-C3-LPAEI/GOX bioanodes were capable of generating 44.9 ± 1.3 µAcm-2 after five hours …

    oklahoma-thes Repository record for Electrochemical Characterization of Photocurable and Layer-By-Layer Assembled Ferrocene-Modified Linear Poly(ethylenimine) Bioelectrodes (opens in a new tab)

Page 1 of 7