OPTIMIZING RF AND GRADIENT COILS IN MRI
In this dissertation, several topics on gradient and RF coils in MRI system are studied. Chapter 1 provides an introduction to basics of MRI. Chapter 2 and Chapter 3 focus on methods of eddy current and heat calculation induced by a gradient coil system. A strip model is studied in detail, and …
-
NEW DIRECTIONS IN THE DESIGN OF MRI GRADIENT COILS
In this dissertation new designs for gradient coils are presented. The principal work is on better shielding for fringe field reduction. Fringe fields from gradient coils produce eddy currents in surrounding metal structures. Such eddy currents can degrade image quality and lead to acoustic noise. …
-
Novel geometry gradient coils for MRI designed by genetic algorithm
This thesis concerns the design of gradient coils for magnetic resonance imaging systems. The method of design by genetic algorithm optimisation is applied to novel gradient geometries both by use of conventional computer facilities, and, by parallelisation of the design algorithm, on a …
-
On the employment of matrix gradient coils for novel spatial encoding and magnetic field shimming in magnetic resonance imaging
… Therefore in the recent past so-called matrix gradient coils, which consist of a large number of small coils, were introduced. The current in each such coil element can be adjusted individually, and the final field shape is given by the superposition of the fields of all coil elements. Such an …
-
Magnetic field issues in magnetic resonance imaging
… over a prescribed imaging volume. In the gradient coil, the entire design for the axial elliptical coil, and the mathematical foundation for the transverse elliptical coil have been presented. Also, the design of a self-shielded cylindrical gradient coil with a restricted length has been …
-
Gradient and rf coil issues in magnetic resonance imaging
Techniques are presented for new analysis of coils in magnetic resonance imaging that should lead to faster and more accurate pictures of humans. Insertable planar, cylindrical or elliptical gradient coils offer the potential for significant performance increases in magnetic resonance imaging. …
-
Improvements in Diffusion Weighted Imaging Through a Composite Body and Insert Gradient Coil System
… brain damage to potential prediction of stroke. Gradient coil and signal-to- noise ratio (SNR) constraints limit spatial resolution, accuracy, and scan time in DMRI. Achieving high b-values (measures of a scan's sensitivity to diffusion) often require scans with long diffusion gradient pulses, …
-
Spin-lattice relaxation in normal alkanes at elevated pressures
… range of 10 to 250 C. Since the magnetic field gradient coils are inside the pressure vessel, the diffusion measurements may be performed with either pulsed or constant gradients. Spin-lattice relaxation times of octane, decane, dodecane, and hexadecane were measured at temperatures between 10 …
-
An investigation into a flux-pumped high-temperature superconducting MRI system
… thesis focuses on the design of an HTS magnet, gradient coils, and a cryostat for a prototype of a fully HTS MRI instrument. In addition to the design of the magnet, this work also focuses on the thermal analysis of the cryostat. The in-house design and fabrication of gradient coils for the MRI …
-
The role of magnetic field gradients in nuclear magnetic resonance
A high resolution NMR probe was modified with gradient coils (31 mm diameter) for the measurement of translational diffusion and for microscopic imaging, and a larger set of gradient coils (15 cm diameter) was constructed for surface coil diffusion measurements. The magnitudes of the gradients …
-
Alternative winding patterns for twisted solenoid coils with improved characteristics for TRASE MRI
… rely on strong static magnetic fields and gradient coils, resulting in high system complexity, power consumption, acoustic noise, and limited accessibility. The development of low-field MRI systems has the potential to alleviate several of these challenges and motivate alternative spatial …
-
Enhancements to Uniformity of Magnetic Fields at the SNS nEDM Experiment
… restore the MSE field uniformity and cos theta coils designed to test the magnetic cloak in the first part. The second part of this thesis discusses a magnetic coil system designed for the wall depolarization measurement required in Phase 2 of Helium-3 system development. The magnetic coil …
-
Pulsed Field Magnetometry for High-Speed Characterisation of Rare Earth Magnets
… A method for the design of position insensitive gradient coils is presented and compared to a conventional design. By using an inverse Biot-Savat simulation, the coupling from each turn of the pickup coil to the point of interest is calculated and optimum winding positions calculated for …
-
The Development Of Radiofrequency Imaging Techniques And Compact Nmr Systems To Improve Access To Medical Technology
… demonstrate how simple radiofrequency coils and adiabatic pulses can compensate for large magnetic imperfections often found in Halbach magnets. To demonstrate its clinical utility, an R1 relaxometry study was performed on 19F oxygen-probes that were implanted in tissue-engineered …
-
Innovative Robotics for Liquid Environs: MRI Gauss Guns and Drift Nodes
… prior propulsion techniques have been limited to gradient-based pulling through fluid-filled body lumens using the weaker magnetic gradient coils. One mechanism to generate additional force to pierce tissue is an MRI Gauss gun, a device that stores magnetic potential energy in an internal …
-
Measurement of the magnetic field of an RF-encoding birdcage-coil design for magnetic resonance imaging
… currently depends on the use of magnetic field gradient coils to visualize tissue. However, there is an alternate method, which can only use RF to encode the image. The idea behind RF encoding is that it uses spatial phase variation in the RF transmission to encode spatial information in the MRI …
-
Cheaper, Quieter, and More Accessible MRI: Compact High-Speed Switching Power Conversion and New System Architectures
… power transistors enable compact, efficient gradient power amplifiers (GPAs).The prototype design achieves more than 10-fold cost reduction (from >$5,000 to <$300) and order-of-magnitude size reduction compared to existing solutions, while maintaining performance requirements for medical …
-
Development of a desktop high-resolution MRI for microflow visualization
… MRI instrument, consisting of a magnet, gradient coils, gradient amplifiers, and radio frequency (RF) electronics, is presented. To reduce the size and cost of this MRI instrument, a permanent magnetic configuration with a magnetic flux density of 0.6 T is designed with off-the-shelf …