Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 19 of 19 for “"Gage length"”.
-
Design and validation of an apparatus for high temperature fatigue testing in an inert environment.
… by other studies. This research used uniform gage length instead of the standard hourglass specimens used by others. The uniform gage length samples have a lower fatigue life at the lower strain range than published data. The results from uniform gage length samples are believed to be a better …
-
An analysis of the methodologies utilized in determining the transfer length of prestressed concrete members
… methods that are used to determine transfer length. The goal of this study was to quantitatively define some of the many variables that affect transfer length measurement. The variables that were investigated in this study are gage length, gage spacing, strain gage sensitivity, strand …
-
Effective Properties of Randomly Oriented Kenaf Short Fiber Reinforced Epoxy Composite
… and its Young's modulus with varying gage length (10, 15, 20, and 25.4 mm) were investigated. The variation in tensile strength of kenaf fibers was analyzed using the Weibull probability distribution function. It was observed that the Young's modulus of kenaf fiber increased with …
-
Critical Material Parameters for Modeling Devices Made from an Epoxy-Based Shape Memory Polymer
… by rising stress to failure. The standard 10:1 gage width/gage length ratio seemed to over constrain the material. The strain to failure was small, and insufficient for extracting hyperelastic parameters. Using narrower gage width specimens, or perhaps a new specimen design, would benefit …
-
Elevated temperature mechanical properties and corrosion characteristics evaluation of alloy Ht-9
… secondary cracks were observed along the gage length of the SCC test specimens, evaluated by optical microscopy.
-
Development and testing of a Long Gage Strain (LGS) sensor for concrete structure instrumentation
… beam are also instrumented with commercial short gage length strain gages in order to compare the strain outputs of the strain gages to that of the proposed strain sensor. Results prove the accuracy, and reliability of the proposed strain sensor.
-
Full field strain measurement in welds
… of an inch within the three-inch gage length. Furthermore, the strain measured near the edge of the specimen using the mapping technique matched to within .01 % the strain measured by an extensometer attached to the test specimen
-
Bond and strain behavior of horizontal reinforcement in masonry mortar joints
… the mortar. All of these factors determine the length over which the wire may be stressed and strained. This length, labeled "effective gage length" in this paper, provides a convenient means by which the behavior of wire joint reinforcement embedded in mortar may be described and evaluated as a …
-
High-finesse/small gap extrinsic Fabry-Perot interferometer and applications
… output pattern, due to minute changes in cavity length of a small-gap/high-finesse cavity. The direction and magnitude of the shift of a high-finesse peak is directly proportional to that of the applied perturbation. The basic features and principle of operation are studied in detail, and …
-
Scale effects in buckling, postbuckling and crippling of graphite-epoxy Z-section stiffeners
… axial stiffnesses than predicted based on the gage length properties alone. This phenomenon required a post-test adjustment to the data in order to permit comparisons of the experimental and finite element predictions of the response of the gage length on an equivalent basis. Once corrected, …
-
AN APPARATUS FOR TENSILE CHARACTERIZATION OF THERMOPLASTICS AT INTERMEDIATE STRAIN RATES
… in efficient stress transfer throughout its gage length and a smoother transition to dynamic equilibrium. Two in-line load cells were used on both ends of the sample to record load data and ensure symmetric load application. Digital image correlation along with high-speed camera was used for …
-
The mechanical properties of reinforcing steel bars at low temperature.
… load cells. The strains were measured with a 2" gage length extensometer, and the fracture strain was measured with calipers. The results of the tension tests showed that the yield and fracture stresses increase with decreasing temperature. The magnitude of the fracture strain does not change …
-
High-Strain Rate Tensile Characterization Of Graphite Platelet Reinforced Vinyl Ester Based Nanocomposites Using Split-Hopkinson Pressure Bar
… Uniform stress distribution within the specimen gage length has been verified using high-speed digital photography. The on-specimen strain gage installation is substituted by a non-contact Laser Occlusion Expansion Gage (LOEG) technique for infinitesimal dynamic tensile strain measurements. Due …
-
Experimental Studies of Reinforcing Steel and Shape Memory Alloys in Mechanically Spliced Connections for Seismic Application
… CAM bars can be only manufactured in limited lengths, making it necessary to splice several bars in series in order to reinforce the entire column plastic hinge.This study focused on experimental studies of the performance of large diameter CAM bars in a multi-splice connection, evaluating …
-
Effects of specimen geometry on tensile ductility, The
… mm thick and uncoated. Specimen geometries had gage lengths ranging from 10 to 80 mm and gage widths from 2.4 to 25 mm. All specimens were tested in room temperature air using a constant crosshead velocity determined for each specimen geometry to produce an engineering strain rate of 0.001 s^-1. …
-
Tensile Material Properties of Human Costal Cartilage Perichondrium
… samples and ~1 mm for one-layered samples. The gage length of the completed coupons was marked with a black ink dot pattern to facilitate strain calculations via video tracking. The coupons were loaded axially in tension to failure at either a slow (0.005 s⁻¹) or fast (0.5 s⁻¹) target loading …
-
Material Properties of the Grade 300 and Grade 270 Prestressing Strands and their Impact on the Design of Bridges
… to be done to include stress-corrosion, transfer length, development length, and flexural strength, the completed testing indicates that less strand will be required using Grade 300 strand versus Grade 270 strand to achieve a set span length and transverse girder spacing. In addition, with the …
-
Effects of Sex, Strain Rate, and Age on the Tensile and Compressive Material Properties of Human Rib Cortical Bone
… was used to measure displacement within the gage length of the tension coupons and a deflectometer was used to measure displacement of the compression samples. Tension data were obtained from fifty-eight (n = 58) coupons at 0.005 strain/s and fifty-eight (n = 58) coupons at 0.5 strain/s, with …
-
Complete stress-strain characteristics of high performance concrete
High performance concrete (HPQ has recently become a widely used concrete construction material for modem buildings, bridges, and pavements, etc. To produce such a better quality of concrete, chemical and mineral admixtures such as fly ash, slag cement, and silica fume, ground granulated blast …