Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 35 for “"Gamma Imaging"”
-
Positron enhanced prompt gamma imaging
… area but instead to healthy tissue. Prompt Gamma Imaging (PGI) is a technique that has been developed to reconstruct the dose deposition, using a Compton Camera (CC). PGI uses the prompt ys produced by inelastic scatters between the proton beam and nuclei within the target. These y rays are …
-
Uranium Holdup Mass Quantification by Hybrid Gamma Imaging
… as 50%. The research presented here is exploring gamma-ray imaging as a more accurate method of quantifying deposits. A PHDs Germanium Gamma Imager (GeGI) is used with a coded aperture mask to simultaneously collect coded-aperture and Compton images that make use of the entire gamma-ray emission …
-
Towards the application of prompt-gamma imaging in online adaptive proton therapy
… Verifikationsmethode, wobei sich die Prompt-Gamma-Bildgebung (engl. prompt-gamma imaging, PGI) als besonders vielversprechend erwiesen hat. Diese Dissertation hatte zum Ziel, PGI für die Anwendung in der OAPT weiterzuentwickeln. Der PGI-Workflow wurde wesentlich optimiert und erfolgreich für …
-
Design study of a Compton camera for prompts-gamma imaging during ion beam therapy
… est de détecter avec une caméra Compton le gamma prompt émis lors des fragmentations nucléaires pendant l'irradiation du patient. Dans un premier temps, la géométrie de deux types de caméra Compton (double diffusion puis simple diffusion) a été optimisée par simulation Monte Carlo. Cette …
-
A new treatment planning concept accounting for prompt gamma imaging for proton range verification
… oder durch anatomische Veränderungen. Prompt-Gamma-Bildgebung (PG) eröffnet die Möglichkeit, die Protonenreichweite in vivo zu beobachten, indem Prompt-Gammas detektiert werden, die durch Kernrelaxation innerhalb des Strahlengangs emittiert werden. Studien haben gezeigt, dass die Genauigkeit …
-
Automated evaluation of prompt gamma imaging data for treatment verification in adaptive proton therapy
… investigated the automatic evaluation of prompt gamma imaging (PGI) range verification data using artificial intelligence (AI). For this purpose, AI-based approaches of varying complexity were developed to detect and classify treatment deviations based on realistically simulated PGI data and then …
-
Automatic classification of treatment-deviation sources in proton therapy using prompt-gamma-imaging information
Prompt-gamma imaging (PGI) was proposed in the 2000s as a promising in vivo range-verification method to maintain the physical advantage of proton beams by reducing unwanted range-uncertainties. Recently, PGI with a slit camera has been successfully implemented in clinical application. Despite its …
-
Development of a portable gamma imaging system for absorbed radiation dose control in molecular radiotherapy
… diagnostique (Flux 2011, Konijnenberg 2011). Les gamma-caméras conventionnelles ne sont ainsi pas adaptées à la détection de fortes activités de rayonnements gamma d'énergies inférieures à 100 keV (²²³ Ra) ou supérieures à 300 keV (¹³¹I, ⁹⁰Y). D’autre part, les fortes activités des traceurs …
-
Studies and optimization of ionization signal measurement for the 3-gamma imaging XEMIS2 liquid xenon Compton camera
… pour la première fois de réaliser l’imagerie 3-gamma sur des petits animaux avec une très faible activité injectée. Le principe de cette nouvelle modalité est de détecter simultanément trois gammas en s'appuyant sur un télescope Compton au xénon liquide simple phase et un émetteur spécifique …
-
Implementation and characterization of the data acquisition system of a Compton camera for prompt gamma imaging in protontherapy
… la délivrance de dose en imageant l’émission des gamma prompts issus des collisions inélastiques entre les particules du faisceau et les noyaux cibles. Ceci requiert de détecter les rayons gamma en utilisant une collimation soit mécanique soit électronique résultant de leurs interactions Compton …
-
Development of a Gamma-Ray Detector based on Silicon Photomultipliers for Prompt Gamma Imaging and High-Energy Spectroscopy
… positron emission tomography (PET) and prompt gamma imaging (PGI) are the most promising methods for in vivo range verification. PET and PGI are indirect approaches to measure protons penetration depth inside patients because they aim to detect secondary particles resulting from the interaction …
-
Development of the XEMIS2 liquid xenon Compton camera for 3-gamma imaging : studies and optimization of scintillation light measurements
… au xénon liquide, conçue pour une imagerie 3-gamma des petits animaux à faible activité. L'objectif principal de XEMIS2 est la localisation en 3 dimensions d'un radiopharmaceutique marqué avec un radionucléide spécifique, tel que le Scandium-44, et la réduction de l'activité administrée tout …
-
Reconstruction of a Radioactive Source Distribution using a Tomographic Spatial-unfolding Method with Compton Gamma Imager Measurements
… materials can be detected through their gamma-ray emissions. There may arise circumstances in which the measurement of these gamma rays must be made from behind a pre-established perimeter, however. To address this, Natural Resources Canada (NRCan) and the National Research Council Canada …
-
Development and Design of a Near-Field High-Energy Gamma Camera for Use with Neutron Stimulated Emission Computed Tomography
A new gamma imaging method, Neutron Stimulated Emission Computed Tomography (NSECT), is being developed to non-invasively and non-destructively measure and image elemental concentrations in vivo. In NSECT a beam of fast neutrons (3 - 5 MeV) bombards a target, inelastically scattering with target …
-
The conceptualization and parameterization of a gaseous detector rasterizing pinhole gamma camera
… of a gaseous detector rasterizing pinhole gamma camera. In this thesis, there is a literature review that describes the historical development of gamma imaging, a technical background that aims to give the reader the prerequisite background knowledge, a methodology, and, a result and …
-
Demonstration of a Cruciform Gamma-Ray Direction-Finder with both Self-Shielding and Compton Imaging Modes
… a Cruciform device that provides both Compton gamma imaging and simple direction-finding based on self-shielding. The Compton imaging and self-shielding modes perform well for detecting a single medium-energy source at multiple azimuthal angles. The performance degrades, however, for both modes …
-
Evaluierung eines Detektionssystems für prompte Gammastrahlung zur Behandlungskontrolle bei klinischen Protonentherapiebestrahlungen
… auf Grundlage von Prompt-Gamma-Imaging (PGI) zur Behandlungskontrolle untersucht. Dafür wurden Messungen mit einem PGI-System während Prostata- und Kopf-Hals-Tumor-Bestrahlungen durchgeführt und retrospektiv ausgewertet. Einerseits konnte dabei mittels PGI die Genauigkeit …
-
Ανάπτυξη συστήματος συλλογής δεδομένων βασισμένο σε προγραμματιζόμενα ηλεκτρονικά (FPGAs) για εφαρμογή σε συστήματα μοριακής απεικόνισης
Recent advances in molecular imaging lead to the early diagnosis and treatment of several diseases. Moreover, molecular imaging techniques are increasingly being used as valuable tools in the drug development process. Conventional clinical imaging techniques provide structural (X-rays, CT, …
-
Experience using a small field of view gamma camera for intraoperative sentinel lymph node procedures
… or the use of a radiotracer with intraoperative gamma counting. The most complex procedures involve the use of blue dye, the use of a radiotracer with preoperative gamma imaging and preoperative gamma counting, intraoperative gamma counting, or some combination of these techniques. The ideal …
Page 1 of 2