Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 87 for “"Gamma camera"”.

  1. Minicomputer Enhancement of Gamma Camera Images

    A prefatory note, in common usage, seems to be an insurance policy drawn against bad reviews, a last ditch attempt to persuade the potential reader to inquire further. That notwithstanding, no such attempt will be made by this writer. Rather, let this brief advertisement remain a simple invitation …

    marquette Repository record for Minicomputer Enhancement of Gamma Camera Images (opens in a new tab)

  2. New to ols For Monitoring Gamma Camera Uniformity

    … performance characteristic of all modern gamma camera systems, and ensuring a stable, uniform detector response is critical for maintaining clinical images that are free of artifact. For these reasons, the assessment of detector uniformity is one of the most common activities associated …

    uthsc Repository record for New to ols For Monitoring Gamma Camera Uniformity (opens in a new tab)

  3. Development of a Silicon Photomultiplier Based Gamma Camera

    … developing a SPECT/MR system is that traditional gamma cameras with photomultiplier tubes are not compatible within magnetic fields. New development in solid state detectors has led to the silicon photomultiplier (SiPM), which is insensitive to magnetic fields.</p> <p>We have developed a small …

    mcmaster Repository record for Development of a Silicon Photomultiplier Based Gamma Camera (opens in a new tab)

  4. DESIGN AND CONSTRUCTION OF A MODULAR GAMMA CAMERA (NUCLEAR)

    The Anger camera has been used for the last quarter century in many areas of science to image gamma radiation. Some typical applications include medicine, where functionality of organs are studied in vivo, and industrial inspection of fuel rods for nuclear reactors. The standard Anger geometry …

    arizona-thes Repository record for DESIGN AND CONSTRUCTION OF A MODULAR GAMMA CAMERA (NUCLEAR) (opens in a new tab)

  5. The conceptualization and parameterization of a gaseous detector rasterizing pinhole gamma camera

    … of a gaseous detector rasterizing pinhole gamma camera. In this thesis, there is a literature review that describes the historical development of gamma imaging, a technical background that aims to give the reader the prerequisite background knowledge, a methodology, and, a result and …

    uoit Repository record for The conceptualization and parameterization of a gaseous detector rasterizing pinhole gamma camera (opens in a new tab)

  6. Applications of Multi-Pinhole Gamma Camera Collimation to Tomography and Image Enhancement

    Recently, multi-pinhole gamma camera collimation has been introduced in the field of emission tomography. This collimation process simultaneously produces several images covering a limited angular range, which may then be recombined to obtain tomographic slices of the object imaged. This study has …

    uiuc Repository record for Applications of Multi-Pinhole Gamma Camera Collimation to Tomography and Image Enhancement (opens in a new tab)

  7. Development and Evaluation of an EMCCD Based Gamma Camera for Preclinical SPECT Imaging

    Pinhole collimation is extremely well suited for imaging radiopharmaceuticals in murine models of human disease. With pinhole collimation, SPECT systems are able to achieve sub-millimeter spatial resolutions. Data from such detailed images are extremely useful for preclinical studies in biomedical …

    utswmed Repository record for Development and Evaluation of an EMCCD Based Gamma Camera for Preclinical SPECT Imaging (opens in a new tab)

  8. Development of a Cadmium Zinc Telluride Based Gamma Camera for Simultaneous SPECT/MR Imaging

    … led to the requirement for development of new gamma camera designs using modern solid state detectors. We have developed the hardware and software for a gamma camera design using cadmium zinc telluride detector technology. The camera will be used in a SPECT system being made up of multiple …

    mcmaster Repository record for Development of a Cadmium Zinc Telluride Based Gamma Camera for Simultaneous SPECT/MR Imaging (opens in a new tab)

  9. Experience using a small field of view gamma camera for intraoperative sentinel lymph node procedures

    … or the use of a radiotracer with intraoperative gamma counting. The most complex procedures involve the use of blue dye, the use of a radiotracer with preoperative gamma imaging and preoperative gamma counting, intraoperative gamma counting, or some combination of these techniques. The ideal …

    gatech Repository record for Experience using a small field of view gamma camera for intraoperative sentinel lymph node procedures (opens in a new tab)

  10. Optical modeling, design optimization, and performance analysis of a gamma camera for detection of breast cancer

    … and analyze the performance of the UA modular gamma camera. Initially we provide a brief background on nuclear medical imaging with scintillation cameras. The key hardware components of a camera are introduced, and some of the fundamental physics involved in the detection of gamma rays is …

    arizona-thes Repository record for Optical modeling, design optimization, and performance analysis of a gamma camera for detection of breast cancer (opens in a new tab)

  11. Computational patient models for simulation of dynamic gamma-camera imaging : Application to renography and peptide receptor radionuclide therapy

    Many nuclear medicine investigations rely on gamma-camera imaging to study and quantify the distribution of radiopharmaceuticals or radionuclides in the patient as a function of time. This is typically used for diagnostic studies of physiological functions or for calculation of absorbed doses …

    lund Repository record for Computational patient models for simulation of dynamic gamma-camera imaging : Application to renography and peptide receptor radionuclide therapy (opens in a new tab) Download PDF for Computational patient models for simulation of dynamic gamma-camera imaging : Application to renography and peptide receptor radionuclide therapy (opens in a new tab)

  12. An MCNP Feasibility Study for a Switchable Radioactive Gamma Source for SPECT Gamma Camera Calibration or Blood Irradiation

    Gamma radiation sources are used for a multitude of applications, including nuclear medicine applications. The current study investigated the feasibility of a switchable radioactive gamma source for two applications: as a calibration source for SPECT gamma cameras; and as a blood irradiator. The …

    carleton Repository record for An MCNP Feasibility Study for a Switchable Radioactive Gamma Source for SPECT Gamma Camera Calibration or Blood Irradiation (opens in a new tab)

  13. Development and Design of a Near-Field High-Energy Gamma Camera for Use with Neutron Stimulated Emission Computed Tomography

    A new gamma imaging method, Neutron Stimulated Emission Computed Tomography (NSECT), is being developed to non-invasively and non-destructively measure and image elemental concentrations in vivo. In NSECT a beam of fast neutrons (3 - 5 MeV) bombards a target, inelastically scattering with target …

    duke Repository record for Development and Design of a Near-Field High-Energy Gamma Camera for Use with Neutron Stimulated Emission Computed Tomography (opens in a new tab)

  14. Development of the MRC-SPECT-II system: a MR-compatible small-animal SPECT system based on semiconductor imaging spectrometers and a Synthetic Compound-Eye gamma camera design

    … innovative geometry named Synthetic Compound-Eye gamma camera, bioinspired to compound eyes often found as vision system in small invertebrates. Preliminary studies demonstrate that the proposed system offers an unprecedented spectroscopic performance (1.71 ± 0.28 keV at 122 keV) in a broad energy …

    uiuc Repository record for Development of the MRC-SPECT-II system: a MR-compatible small-animal SPECT system based on semiconductor imaging spectrometers and a Synthetic Compound-Eye gamma camera design (opens in a new tab)

  15. Ανάπτυξη τομοσπινθηρογραφικού συστήματος υψηλής ευαισθησίας και διακριτικής ικανότητας

    … planar images are taken with the use of a gamma Camera, the physical operating principle of which remains unchanged for almost half a century. This PhD thesis had as main objective the development of a modern small field gamma Camera system with high sensitivity and resolution, based on …

    greece Repository record for Ανάπτυξη τομοσπινθηρογραφικού συστήματος υψηλής ευαισθησίας και διακριτικής ικανότητας (opens in a new tab)

Page 1 of 5