Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 49 for “"Gamma index"”

  1. Validation of radiation treatment planning with a pseudo-CT derived from MR images

    … and monitor units. Dose point calculation and gamma index was used to access the dose accuracy. The point dose calculation agreement and the percentage of points passing the gamma index are excellent for the pseudo-CT and bulk methods with very minimal difference compared to the reference CT. …

    missouri Repository record for Validation of radiation treatment planning with a pseudo-CT derived from MR images (opens in a new tab)

  2. Mitigating anatomical changes in head and neck radiotherapy

    … model, whose average anatomical uncertainty and gamma index are 4.47±1.23 mm and 93.87±0.83% at week 6, respectively, the refined individual model reduces anatomical uncertainty to 1.89±1.23 mm and improves the gamma index to 96.16±1.84% at week 6. In Chapter 6, a proposed flexible strategy …

    ucl Repository record for Mitigating anatomical changes in head and neck radiotherapy (opens in a new tab)

  3. New approaches to improving the accuracy and outcome of Intensity Modulated Radiotherapy

    … differ. A new method of calculating the popular Gamma index is proposed, along with a new Kappa index which can highlight areas of dose mismatch more readily than the Gamma index. Using a specially developed dose calculation system, systematic errors found with the IMRT treatment machines at …

    the-open-u Repository record for New approaches to improving the accuracy and outcome of Intensity Modulated Radiotherapy (opens in a new tab)

  4. Development of Monte Carlo Treatment Planning and Dosimetry System for Small Animal Irradiator

    … and compared with MC simulations. The standard gamma index method with AAPM TG 53 recommendations are used to benchmark the measurements (radio chromic film) against planar dose (Monte Carlo simulation) along with isodose lines and profiles in both homogeneous and heterogeneous mediums. The …

    utswmed Repository record for Development of Monte Carlo Treatment Planning and Dosimetry System for Small Animal Irradiator (opens in a new tab)

  5. Quality Assurance of Advanced Treatment Modalities Using Presage® Dosimeters

    … with 2D measurements within ±5%/3mm using a gamma index analysis. The PRESAGE® dosimeter will detect dose discrepancies not detected with 2D measurements resulting in a 5% change in the normal tissue complication probability (NTCP). An optical CT scanner was tested for reproducibility and …

    uthsc Repository record for Quality Assurance of Advanced Treatment Modalities Using Presage® Dosimeters (opens in a new tab)

  6. Evaluation of Intensity Modulated Radiation Therapy (Imrt) Delivery Error Due to Imrt Treatment Plan Complexity and Improperly Matched Dosimetry Data

    … 4 mm distance-to-agreement (DTA). Additionally, gamma index analysis was performed for all deliveries using a ±7%/4mm and ±5%/3mm criteria. Increasing the treatment plan complexity by varying the MU, number of segments, or varying the MCS resulted in no clear trend toward an increase in …

    uthsc Repository record for Evaluation of Intensity Modulated Radiation Therapy (Imrt) Delivery Error Due to Imrt Treatment Plan Complexity and Improperly Matched Dosimetry Data (opens in a new tab)

  7. Development of a Monte Carlo Simulation Model for Varian ProBeam Compact Single-Room Proton Therapy System using GEANT4

    … Integrated Depth-Dose curves using a 2%/2mm gamma index test with 100% of points passing. The beam spot standard deviation sizes (s!) were compared using percent deviation. All simulated s! matched the experimental s! within 2.5%, except 70 and 80 MeV. The model can be used to develop a more …

    fau Repository record for Development of a Monte Carlo Simulation Model for Varian ProBeam Compact Single-Room Proton Therapy System using GEANT4 (opens in a new tab)

  8. Σχεδιασμός πλάνων θεραπείας με τεχνικές 3D-CRT και VMAT και μελέτη επιβεβαίωσης των πλάνων με δυο ανεξάρτητες δοσιμετρικές μεθόδους

    … των δυο κατανομών έγινε η χρήση της μεθόδου Gamma- Index. Με κριτήρια αποδοχής 3mm και 3%, οι ποσοστιαίες διαφορές μεταξύ των δύο κατανομών βρέθηκαν μικρότερες από 7% για το Delta4 ενώ για τα ομοιώματα δοσιμετρίας γέλης πολυμερισμού, με κριτήρια αποδοχής 2mm και 3%, οι ποσοστιαίες διαφορές …

    athens Repository record for Σχεδιασμός πλάνων θεραπείας με τεχνικές 3D-CRT και VMAT και μελέτη επιβεβαίωσης των πλάνων με δυο ανεξάρτητες δοσιμετρικές μεθόδους (opens in a new tab)

  9. Transit dosimetry based on water equivalent path length measured with an amorphous silicon electronic portal imaging device

    … with calculated doses from TPS at the exit. The gamma index at 3% dose difference (DD) and 3mm distance to agreement (DTA) resulted in an average of 97% acceptance for the square fields of 5, 10, 15 and 20 cm thickness solid water homogeneous phantoms. More than 90% of all points passed the gamma …

    glasgow Repository record for Transit dosimetry based on water equivalent path length measured with an amorphous silicon electronic portal imaging device (opens in a new tab)

  10. Human Footpaths in the Outer Suburbs of Ottawa: Distribution, Network Connectivity, and Walkability

    … is measured using the link-node ratio, the gamma index, and the alpha index, as well a node betweenness centrality. Walkability is measured in ArcGIS through an origin-destination cost matrix. The results show that the distribution of footpaths cannot be explained by the selected variables. …

    ottawa-retro Repository record for Human Footpaths in the Outer Suburbs of Ottawa: Distribution, Network Connectivity, and Walkability (opens in a new tab)

  11. Implementación de un protocolo de control de calidad para el paciente específico de radioterapia de intensidad modulada (IMRT) usando la película Kodak EDR-2

    … punto con coincidencia de dosis (DTA), función Gamma e índice Gamma, este último para la valoración cuantitativa de las distribuciones de dosis. A partir de los resultados se halló el grado de coincidencia entre las distribuciones y basados en los criterios de tolerancia fijados en el 3% para la …

    un-colombia Repository record for Implementación de un protocolo de control de calidad para el paciente específico de radioterapia de intensidad modulada (IMRT) usando la película Kodak EDR-2 (opens in a new tab)

  12. Development of end-to-end tests for online adaptive magnetic resonance-guided radiotherapy

    … pelvis phantom. These tests resulted in Gamma-index passing rates (3 %⁄ 3 mm) of 93.1 % (i) and 98.9 % (ii) for the PG-filled targets and demonstrated the feasibility of online adapted MRgRT in presence of inter-fractional anatomical changes.

    heid-diss Repository record for Development of end-to-end tests for online adaptive magnetic resonance-guided radiotherapy (opens in a new tab)

  13. Eine neue dreidimensionale Online-Dosisverifikationsmethodik in der intensitätsmodulierten Radiotherapie zur Steigerung der Patientensicherheit und Optimierung des Therapieverlaufs

    … Verifikationsmethodik erfüllten alle Pläne das Gamma-Index Kriterium ((98,1±1,6) % für γ(2%,2mm)). Gegenüber der Dosisberechnung in 3D stimmte die auf Transmissionsmessungen basierende Dosis-rekonstruktion mit einem mittleren Gamma-Index von 0,29 ± 0,07 im Vergleich zur Solldosisvertei-lung gut …

    heid-diss Repository record for Eine neue dreidimensionale Online-Dosisverifikationsmethodik in der intensitätsmodulierten Radiotherapie zur Steigerung der Patientensicherheit und Optimierung des Therapieverlaufs (opens in a new tab)

  14. Μελέτη και ανάπτυξη μεθόδων δοσιμετρικής επαλήθευσης πλάνων θεραπείας σε σύγχρονες τεχνικές ακτινοθεραπείας

    … way. The ISD method was compared to the gamma index using intentionally erroneous VMAT and IMRT plans. Results revealed that the ISD method is sensitive to all errors induced in the plans. Discrepancies are presented per isodose, enabling the evaluation of the plan in two regions, which …

    greece Repository record for Μελέτη και ανάπτυξη μεθόδων δοσιμετρικής επαλήθευσης πλάνων θεραπείας σε σύγχρονες τεχνικές ακτινοθεραπείας (opens in a new tab)

  15. Implementación de un sistema de radiografía computarizada para verificación de tratamientos de radioterapia de intensidad modulada

    … herramienta de análisis de acuerdo el índice gamma y el índice chi, aplicados sobre tres planes dosimétricos: uno de cabeza y cuello, otro de cérvix uterino y otro de próstata. Se concluye que el sistema de radiografía computarizada es una herramienta viable para fines de dosimetría y control …

    un-colombia Repository record for Implementación de un sistema de radiografía computarizada para verificación de tratamientos de radioterapia de intensidad modulada (opens in a new tab)

  16. Avaliação do movimento respiratório em radioterapia utilizando simulação Monte Carlo

    … the results of the dose profiles using the gamma index with criteria of 3% / 3mm.The experimental measurements were performed using radiochromic films with the phantom static, in motion and with the phantom in motion and the triggering of the beam. For the simulation with Monte Carlo method, …

    brazil-uerj Repository record for Avaliação do movimento respiratório em radioterapia utilizando simulação Monte Carlo (opens in a new tab)

  17. Influence on different Monte-Carlo variances at the dose calculation and the impact to the commissioning

    … using OmniPro I’mRT software, which employs the gamma evaluation criteria for comparing two dose distributions. Results: Calculation time increased with increase in field size and with reduction in the calculation variance. The calculated dose distribution also concords more with the measured at …

    heid-thes Repository record for Influence on different Monte-Carlo variances at the dose calculation and the impact to the commissioning (opens in a new tab)

  18. On the Development of Computational Methods to Help in Performing Medical Physics Tasks Leveragin the Portal Dosimetry Application

    … images and reduce the QA time when performing gamma analysis at varying test criteria and evaluating the results of the Winston-Lutz test. The application leverages the Eclipse Scripting API (ESAPI) within the Eclipse Treatment planning system of Varian Medical Systems. The Portal Dosimetry …

    unlv Repository record for On the Development of Computational Methods to Help in Performing Medical Physics Tasks Leveragin the Portal Dosimetry Application (opens in a new tab)

Page 1 of 3