Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 27 for “"Gamma source"”.
-
Passive Gamma Source Imaging Using Compressed Sensing Principles
A design concept for imaging radiation sources using compressed sensing (CS) principles was developed in this research. A proof-of-concept system model was designed using Monte Carlo N-Particle (MCNP) simulations. The resulting conceptual system comprised a collimator made of 11×11 polyvinyl …
-
Gamma Source Localization Using True-Range Multilateration Methods to Compare NaI and CZT Detector Types
… various methods and approaches to localize a gamma source using experimental measurements with NaI and CZT detectors within a glovebox environment. Gamma Detector Response and Analysis Software was used to simulate spectra from the environment and perform the same gamma source localization as …
-
An MCNP Feasibility Study for a Switchable Radioactive Gamma Source for SPECT Gamma Camera Calibration or Blood Irradiation
Gamma radiation sources are used for a multitude of applications, including nuclear medicine applications. The current study investigated the feasibility of a switchable radioactive gamma source for two applications: as a calibration source for SPECT gamma cameras; and as a blood irradiator. The …
-
Radioactive Source Localization Using True-Range Multilateration Methods
… methods and approaches used to localize a gamma source and a neutron source using true-range multilateration. The developed algorithm is based on the inverse-square law relationship between the source intensity measured by a detector and the distance the source is from that detector. This …
-
Development of a Novel Fuel Burnup Methodology and Algorithm in RAPID and its Benchmarking and Automation
… concentrations and intrinsic neutron and gamma source strengths as a function of irradiation and cooling time. Detailed, full-core 3D burnup calculations are critical for nuclear fuel management studies, including core design and spent fuel storage safety and safeguards analysis. For core …
-
Charged Pion Photoproduction Cross Section and Beam Asymmetry Measurement on HD
The charged pion production reactions d(gamma,pi<sup>+</sup>n), d(gamma,pi<sup>-</sup>p), HD(gamma,pi<sup>+</sup>n)X were studied using linearly polarized gamma-rays with energies in the range from 260 MeV to 370 MeV at the Laser Electron Gamma Source (LEGS). A solid HD target was used in this …
-
Modeling the Impact of Container Material and Geometry on the Uniformity of Dose in Irradiation Calibration
In order to calibrate radiation sources in instruments used by the Optically Stimulated Luminescence Laboratory at ECU, samples are sent in containers to an external gamma source to be irradiated with a known radiation dose. The type of material used for the container can have an effect on the …
-
Photon flux monitor for a mono-energetic gamma ray source
… for use at the Duke University High Intensity Gamma Source, where the photon beam produced is essentially mono-energetic but it is not tagged. Direct counting of the number of photons using a high-efficiency detector is not possible because of the high photon fluxes expected. Therefore, a …
-
Photodisintegration of the Deuteron at 18 MeV using Linearly Polarized Photons
… in October 2010 using the High Intensity Gamma Source at the Duke Free-Electron Laser Laboratory located at Duke University in Durham, North Carolina. The ejectile neutrons from the photodisintegration reaction were measured using the Blowfish detector array: a spherical array of 88 BC-505 …
-
Electron Recoils In the PICO Direct Dark Matter Detection Experiment
… keV. At this threshold, a 141 Bq Cf-252 neutron source and a 33 MBq Co-60 gamma source can be used to calibrate the nuclear and electron recoil response of PICO-40L. Existing sources have sufficient strengths to calibrate PICO-500 to the statistical accuracy required, provided that the …
-
An experimental study of the relative response of plastic scintillators to photons and beta particles within the context of tritium monitoring
… have been carried out using four different gamma sources with different energies ranging from 6keV to 1.332MeV and a Ni-63 beta source of maximum energy of 66keV. A simulation was also carried out in MCNP4a to verify the number of H-3 beta particles with max energy 18.6keV that would reach …
-
Characterization of Radiation Fields and Dose Assessment From Fuels Manufacturing For Advanced Fuel Cycles
… (RepU). Of particular concern is the increase in gamma source term from the daughter products in RepU and the mixed neutron and gamma fields introduced by MA recycle. In the interest of keeping the glovebox worker's radiation dose as low as reasonable achievable (ALARA), dose rates were calculated …
-
Synthesis and characterization of cerium-doped lanthanum halide colloidal nanocrystals
… (variation in emission light yield to absorbed gamma energy) for 662 keV gamma rays, 25 ns short decay time, and a density of 5.3 g/cm3 with 22 mm attenuation length for 511 keV gamma rays. However, the crystals are hygroscopic and hence have to be protected from external environment both during …
-
Characterization of Czochralski silicon detectors
… high-energy electrons) and tested with a 60Co gamma source and with high-energy muon and pion beams. The electrical characterizations show that, for proton irradiation, the MCZ silicon is significantly radiation harder than traditionally used detector materials. In gamma irradiation, MCZ …
-
The design, fabrication, and characterization of polymer-carbon nanotube composites
… and initiated via thermal energy, UV light, and gamma radiation. Composite films with increased dielectric constants and unique optical transparency were produced. Samples were characterized using differential scanning calorimetry, dielectric analysis, and dynamic mechanical analysis. Refractive …
-
Gamma-ray Imaging Diagnostic for Inertial Confinement Fusion
… 12 of the plastic outer shell producing 4.44 MeV gammas from 12C(n,n’γ)12C reactions. This dissertation examines and produces a prototype system to image these 4.44 MeV gammas. This is a valuable diagnostic system that can characterize the symmetry of the ablated surface, which gives information …
-
Examination of secondary electrons generated by encapsulated gamma sources to improve contact dosimetry estimates
… generation on the surface of encapsulated gamma sources can play a large role in the dose measured near the surface of the encapsulation. The National Council on Radiation Protection and Measurements (NCRP) Report - 40 contains contact dose rate conversion factors for encapsulated gamma …
-
Radiation damage effects on the structure and properties of radioactive waste glasses
… disposal fission products will me the main source or radiation and they decay by beta-gamma emission. We studied different borosilicate glasses used in different countries to immobilise HLW, such as Indian glass (NaBaBSi), UK glasses (LiNaBSi), also called MW- Mixture Windscale, UK-CaZn a …
-
Radiochemical Transformation of High Pressure Methane under Gamma, Electron, and Neutron Irradiation
… and noble gas mixtures were investigated using gamma, electron beam, and neutron irradiation sources. The gamma source used was the La-140 source from the Nuclear Science Center (NSC) at an activity of 400 Ci. The electron source was a 10 MeV, 15 kW, linear accelerator at the National Center for …
-
Development of a Multi-layer Silicon Beta-ray Spectrometer for Beta Spectrometry and Dosimetry at CANDU Power Plants
… effect for workers exposed to a mixed beta-gamma radiation field observed at Canada Deuterium Uranium (CANDU) power plants. Accurate beta dosimetry to the lens of the eyes in a mixed field remains a challenge due to limitations in existing beta spectrometers. In this dissertation, a compact …
Page 1 of 2