Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 45 for “"Gamma-ray detection"”.

  1. The efficiency of scintillation counters for gamma ray detection

    … of NaI(T1) scintillation counters for the detection of gamma rays is discussed and experimentally determined. Experimental efficiencies, based upon the number of counts above a bias equal to one-half the gamma ray energy and a solid angle defined to the crystal effective centre, for a …

    ubc Repository record for The efficiency of scintillation counters for gamma ray detection (opens in a new tab) Download PDF for The efficiency of scintillation counters for gamma ray detection (opens in a new tab)

  2. Barium Based Halide Scintillator Ceramics For Gamma Ray Detection

    … on a class of materials attractive for use as gamma-ray scintillators. These barium based halides can potentially be utilized in applications ranging from ionizing radiation detection in the field to high-energy physics experimentation. Barium bromide iodide and barium chloride single crystals …

    ucf Repository record for Barium Based Halide Scintillator Ceramics For Gamma Ray Detection (opens in a new tab)

  3. Safeguards assessment of gamma-ray detection for process monitoring at natural uranium conversion facilities

    … as a key measurement point (KMP), where gamma-ray spectroscopy was selected as the process-monitoring tool. The Uranyl Nitrate Calibration Loop Equipment (UNCLE) facility at Oak Ridge National Laboratory was employed to simulate the full-scale operating conditions of a purified …

    gatech Repository record for Safeguards assessment of gamma-ray detection for process monitoring at natural uranium conversion facilities (opens in a new tab)

  4. The Development of Cesium Calcium Bromo-Iodide scintillator for X-ray and Gamma ray detection

    … crystals with bromine content x > 0.6. Powder X-ray diffraction data coupled with differential scanning calorimetry and radioluminescence measurements were used to investigate structural modifications, melting point dependence and spectral emission dependence on the bromine/iodine ratio. Partial …

    ut-knoxville Repository record for The Development of Cesium Calcium Bromo-Iodide scintillator for X-ray and Gamma ray detection (opens in a new tab)

  5. Critical assessment of the MEDUSA gamma ray detection system for radon flux measurement on a tailings dam

    … the investigation of a new- technique based on gamma ray spectrometry to quantitatively assess the radon flux from the mine tailings dam. The system is called Multi Element Detector for Underwater Sediment Activity (MEDUSA). Initially, this technique was uniquely designed to measure the …

    nwu-za Repository record for Critical assessment of the MEDUSA gamma ray detection system for radon flux measurement on a tailings dam (opens in a new tab)

  6. New algorithm for neural network data discrimination applied to Markarian 421 high energy gamma rays

    … The algorithm is applied to cosmic high energy gamma ray detection and is further used for determining the spectral index of the Markarian 421 source.

    concordia Download PDF for New algorithm for neural network data discrimination applied to Markarian 421 high energy gamma rays (opens in a new tab)

  7. Resolution and line shape in scintillation counters

    … crystals of similar sizes. It is shown that for gamma-ray detection an important contribution to the line width originates with variations in the light collection efficiency from different regions of the scintillators.

    ubc Repository record for Resolution and line shape in scintillation counters (opens in a new tab) Download PDF for Resolution and line shape in scintillation counters (opens in a new tab)

  8. Estimation methods for semiconductor gamma-ray detectors

    Gamma-ray detectors based on high-density semiconductors, such as cadmium zinc telluride, are being developed for applications in nuclear medicine, astronomy and the monitoring of nuclear weapons material. In contrast to the more commonly used scintillators, which convert gamma-ray energy into …

    arizona-thes Repository record for Estimation methods for semiconductor gamma-ray detectors (opens in a new tab)

  9. Development of a Real-Time Detection Strategy for Material Accountancy and Process Monitoring During Nuclear Fuel Reprocessing Using the Urex+3A Method

    … a safeguards strategy based on qualitative gamma ray and neutron measurements is proposed. The gamma ray detection equipment used in the safeguard strategy could also be used to improve the real-time process monitoring in a yet-to-be built facility. A facility that had real-time gamma …

    tamu Repository record for Development of a Real-Time Detection Strategy for Material Accountancy and Process Monitoring During Nuclear Fuel Reprocessing Using the Urex+3A Method (opens in a new tab)

  10. Performance of HAGRID array in beta delayed neutron emission measurements

    … by the emission of a neutron. The Versatile Array of Neutron Detectors at Low Energy (VANDLE) is a proven detection system for measuring the energies of delayed neutrons. VANDLE has been upgraded to include high-efficiency scintillators for gamma-ray detection. This increases the sensitivity …

    ut-knoxville Repository record for Performance of HAGRID array in beta delayed neutron emission measurements (opens in a new tab)

  11. Thermal Characteristics of Lithium Indium Diselenide and Lithium Indium Gallium Diselenide Neutron Detection Crystals

    … weapons, medicine, and science. Neutron and gamma ray detection are the primary methods of detecting SNM. Increased movement and availability of SNM have increased the demand for radiation detection systems beyond the capacity of traditional neutron detection technologies (<sup>3</sup>He) …

    ut-knoxville Repository record for Thermal Characteristics of Lithium Indium Diselenide and Lithium Indium Gallium Diselenide Neutron Detection Crystals (opens in a new tab)

  12. The measurement of neutron activation cross sections in the energy range 3.5 Mev to 6.0 Mev

    … Permissible in conventional gas targets. The gamma-ray activities induced in the irradiated samples were determined using a 7.62 em x 7.62 em Nai(TI) detector. The gamma-ray detection efficiencies were corrected for sample self­ scattering and self-absorption using the Monte Carlo method. A …

    aston Download PDF for The measurement of neutron activation cross sections in the energy range 3.5 Mev to 6.0 Mev (opens in a new tab)

  13. Analytical Separation of Zirconium-95 and Niobium-95 from Uranium Irradiated by Thermal Neutrons

    … and because of the high level of penetrating gamma radiation emitted by radioactive zirconium and its daughter niobium. In this thesis, after discussing the origin of the problem, methods For the separation of Fission products have been reviewed. An investigation was conducted into the ability …

    aston Download PDF for Analytical Separation of Zirconium-95 and Niobium-95 from Uranium Irradiated by Thermal Neutrons (opens in a new tab)

  14. An Analysis of a Spreader Bar Crane Mounted Gamma-Ray Radiation Detection System

    … of entry. The current layered approach for the detection only scans 5% of cargo bound for the United States. This is inadequate to protect our country. This research involved the building of a gamma-ray radiation detection system used for cargo scanning. The system was mounted on a spreader bar …

    tamu Repository record for An Analysis of a Spreader Bar Crane Mounted Gamma-Ray Radiation Detection System (opens in a new tab)

  15. A comparison of the use of sodium iodide and lanthanum bromide scintillation crystals for airborne surveys

    … major releases or lost sources. Two radiological detection systems are used by the ASPECT team for gamma-ray detection and characterization: lanthanum bromide [LaBr3(Ce)] and sodium iodide [NaI(Tl)] scintillation systems. An aerial survey of a uranium mine in the western United States was …

    colostate Repository record for A comparison of the use of sodium iodide and lanthanum bromide scintillation crystals for airborne surveys (opens in a new tab)

  16. Spectroscopy of neutron unbound states in 24O and 23N

    … separation energy. However, due to the lack of $\gamma$-ray detection, a definitive statement on the structure of $^{23}$N could not be made. Shell model calculations with the WBP and WBT interactions lead to several interpretations of the spectrum. Both a single state at 2.9 MeV in $^{23}$N, or …

    msu Repository record for Spectroscopy of neutron unbound states in 24O and 23N (opens in a new tab)

  17. Neutron-rich chromium and manganese isotopes and the role of the neutron 0g2089/₂ and 1d2085/₂ orbitals in the region below 20762078Ni

    … from inelastic proton scattering measurements.&gamma-ray spectroscopy was performed on <super>63</super>Mn and a new transition was added to the level scheme. Excited-state lifetimeswere determined for levels in <super>62</super>Cr and <super>63</super>Mn using simulationsof the &gamma-ray …

    msu Repository record for Neutron-rich chromium and manganese isotopes and the role of the neutron 0g2089/₂ and 1d2085/₂ orbitals in the region below 20762078Ni (opens in a new tab)

Page 1 of 3