Results 1 to 6 of 6 for “"Gap Probe"”

  1. Enhancing the Capabilities of the CANDU Gap Probe

    … annulus space between the tubes, known as the gap, ensures that hydride blisters do not form on the outer diameter of the PT, as these can lead to potential cracking. Consequently, accurate measurements are required to ensure that contact between PT and CT is not imminent. The PT-CT gap is …

    queens Repository record for Enhancing the Capabilities of the CANDU Gap Probe (opens in a new tab)

  2. Comprehensive Characterization of Measurement Data Gathered by the Pressure Tube to Calandria Tube Gap Probe

    … pressure tube (PT) to calandria tube (CT) gap in CANDU fuel channels, a critical inspection activity required to ensure fitness for service of fuel channels. In this thesis, a comprehensive characterization of eddy current gap data is laid out, in order to extract further information on …

    queens Repository record for Comprehensive Characterization of Measurement Data Gathered by the Pressure Tube to Calandria Tube Gap Probe (opens in a new tab)

  3. Generating and Simulating CANDU® Fuel Channel Eddy Current Data to Demonstrate Multi-Parameter Extraction Capabilities

    An eddy current probe known as the gap probe is used in CANDU® (CANadian Deuterium Uranium) nuclear reactors to verify that Pressure Tube to Calandria Tube (PT-CT) gap in Fuel Channels is larger than the minimum requirement. Contact between the two tubes can severely reduce the structural integrity …

    queens Repository record for Generating and Simulating CANDU® Fuel Channel Eddy Current Data to Demonstrate Multi-Parameter Extraction Capabilities (opens in a new tab)

  4. Time Domain Reflectometry Measurement of Water Content and Electrical Conductivity Using a Polyolefin Coated TDR Probe

    … was to evaluate the use of a three-rod TDR probe with a polyolefin coating on the center-conducting rod (CCRC probe) to simultaneously measure θv and EC in saline conditions where standard, non-coated TDR probes (NC probe) are ineffective. The application of a 0.00053 m thick polyolefin …

    waterloo Repository record for Time Domain Reflectometry Measurement of Water Content and Electrical Conductivity Using a Polyolefin Coated TDR Probe (opens in a new tab)

  5. Conditional artificial dielectric waveguide

    … of light with a photon energy above the band-gap of the semiconductor ( pump light ) induces electric and magnetic dipoles which affect the propagation of light with a photon energy below the band-gap ( probe light ) in a slab waveguide.</p><p>The polymeric films have been prepared using …

    njit Repository record for Conditional artificial dielectric waveguide (opens in a new tab)

  6. Comprehensive Modelling for Eddy Current Based Pressure Tube to Calandria Tube Gap Measurements

    … tube (PT) and calandria tube (CT), known as gap, in the CANada Uranium Deuterium (CANDU®) nuclear reactor fuel channels is monitored using a drive-receive eddy current probe. Gap measurement accuracy is crucial to ensure contact does not occur between the PT and CT, as contact can lead to …

    queens Repository record for Comprehensive Modelling for Eddy Current Based Pressure Tube to Calandria Tube Gap Measurements (opens in a new tab)