Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 12 of 12 for “"Gas gain"”.

  1. Gas gain studies for MicroMegas detectors and development of the high voltage control system for the detectors of the ATLAS new small wheel upgrade

    … Small Wheel (NSW) wird mit zwei verschiedenen Gasdetektortypen bestückt: MicroMegas (MM) und small-strip Thin Gap Chambers. Es wird ein konstantes Antwortverhalten der MM im Betrieb des NSW gefordert, jedoch kann der Arbeitspunkt der MM durch die Gasdichte und -zusammensetzung sowie die …

    freiburg-diss Repository record for Gas gain studies for MicroMegas detectors and development of the high voltage control system for the detectors of the ATLAS new small wheel upgrade (opens in a new tab)

  2. Theoretical performance analysis of a novel hemispherical tissue equivalent proportional counter for neutron monitoring and dosimetry

    … solve the Townsend equation and calculate radial gas gain distributions for each counter. Through this it was found that the hemispherical counter exhibits completely uniform gas gain for electrons approaching the anode from all directions and its avalanche region occupies only 0.0004% of the …

    uoit Repository record for Theoretical performance analysis of a novel hemispherical tissue equivalent proportional counter for neutron monitoring and dosimetry (opens in a new tab)

  3. Simulation, design and construction of a gas electron multiplier for particle tracking

    … is a technique which uses a tissue equivalent gas to simulate microscopic tissue sites of the order of cellular dimensions and the principles of gas ionization devices to measure deposited energy. The Gas Electron Multiplier (GEM) has been used since 1997 for tracking particles and for the …

    uoit Repository record for Simulation, design and construction of a gas electron multiplier for particle tracking (opens in a new tab)

  4. Design, construction and implementation of spherical tissue equivalent proportional counter

    … rings is low density polyethylene, and the gas inside the detector is propane. The detector, along with the charge sensitive preamplifier, is encased in a stainless steel vacuum chamber. The gas gain was found to be 497.5 at 782 volts and the response to neutrons as a function of angle was …

    tamu Repository record for Design, construction and implementation of spherical tissue equivalent proportional counter (opens in a new tab)

  5. Development of TACTIC: a novel detector for nuclear astrophysics

    … beams and a flexible choice of target gas enable these detectors to make direct measurements of a variety of nuclear reactions. This thesis focuses on the development and commissioning of TACTIC, a cylindrical active-target TPC. The design of TACTIC is suitable for the cross section …

    whiterose Download PDF for Development of TACTIC: a novel detector for nuclear astrophysics (opens in a new tab)

  6. Optically-Pumped CW Mid-Infrared NH₃ Lasers

    … as the dominant mechanism responsible for the gain. The two-photon process results from the coherent interaction of two laser fields with a three-level system and can create gain in the absence of a population inversion. This property was essential to the successful operation of the first …

    mcmaster Repository record for Optically-Pumped CW Mid-Infrared NH₃ Lasers (opens in a new tab)

  7. The Study of Electronegative Gases for Time Projection Chambers

    … and performance of negative ion drift and gas gain in gas-filled radiation detectors with electronegative fill gases. Negative ions drift with slow drift velocity and the lowest possible (thermal limit) diffusion, which leads to relaxed requirements for readout electronics without …

    temple Repository record for The Study of Electronegative Gases for Time Projection Chambers (opens in a new tab)

  8. Towards CYGNUS-UK: Developments in Negative Ion Charge Amplification and Readout Technologies for Directional Dark Matter Detection

    … Projection Chambers (TPCs), using liquid and gaseous xenon, currently lead the direct search for rare WIMP-nucleon scattering events. The sensitivity of these experiments has improved by several orders of magnitude since their inception and are now faced with a new irreducible background of …

    whiterose Download PDF for Towards CYGNUS-UK: Developments in Negative Ion Charge Amplification and Readout Technologies for Directional Dark Matter Detection (opens in a new tab)