HYPERFINE STRUCTURE AND CENTRIFUGAL DISTORTION IN MICROWAVE SPECTRA.
… of iodine in the C-I bond was derived. A gaussmeter specifically built for the determination of magnetic field in an Electron Paramagnetic Resonance experiment was described. A schematic diagram as well as a discussion of hardware was included.
-
Design and Devlopment of a Biostretch Apparatus for Tissue Engineering
… field is modeled by COMSOL, and verified by a Gaussmeter. In addition, one side effect of using electromagnets, that of a temperature increase, is also investigated. The biomedical experiment results show that neither a weak low frequency magnetic field (0.1T, 1Hz) nor an increase of 1℃ in …
-
Novel coil designs for different neurological disorders in transcranial magnetic stimulation
… with the help of an axial Hall probe and a gaussmeter. Furthermore, seven different coils for small animals were presented in this dissertation. These coils had varying electric field with the Slinky coil having the minimum area of stimulation and lowest electric field below 10 mm of the …
-
Low-dosage magnetic field effects on embryonic bone growth.
… in the center of the field was measured with a gaussmeter. Each chick embryo in its magnetic field was isolated from the others by being encased in a steel box. Intramembranous and endochondral ossification were studied. Fluorescent dyes were micropipetted into the amniotic cavity of the chick …
-
Magnetic Field Design, Optimization, Physical Assembly, and Characterization for a High-Power ECR Thruster
… Magnetic characterization was performed using a gaussmeter probe at a fixed solenoid current of 8.5 A. The measured centerline axial field reached 877.4 gauss at the upstream measurement location, satisfying the 875 gauss ECR target. A two-component B(r,z) field map confirmed that the measured …
-
DEVELOPING A HALBACH ARRAY FOR TARGETED DRUG DELIVERY TO BRAIN TUMOURS
… the actual assembled one was 1.1T assessed using Gaussmeter. The concentration of trapped SPIONs in the phantom flow model was different depending on the initial concentration of SPIONs and the location of the tumours within the head phantom. As expected, the further away the tumour was from the …
-
Sound Transmission Analysis of Circular Sandwich Panels Fully and Partially Treated with MR Fluid Core Layer
… with the measured magnetic flux density using Gaussmeter. The results from the magneto-static analysis is used to derive approximate polynomial functions to evaluate the magnetic flux density as a function of the plate’s radius and applied current. In the second part, the sound transmission …
-
Aplikace pro mapování magnetického pole přístrojem F.W.BELL 9950
Cílem tohoto projektu je seznámit čtenáře s možnostmi ovládání měřicího přístroje F.W. Bell 9950 pomocí počítače. V práci je rozebrána problematika měření magnetické indukce a bude představen samotný měřicí přístroj i jeho schopnosti komunikace s PC. Další část práce se již zabývá popisem ovládání …
-
Návrh gaussmetru s tříosou měřicí sondou
Práce se zabývá návrhem gaussmetru s tříosou měřicí sondou pro mapování magnetického pole a následnou rekonstrukci obrazu za pomoci magnetické impedanční tomografie. Komerčně dostupné gaussmetry mají pro tyto účely malou šířku pásma a není možné s nimi měřit v silně zarušených prostředích, protože …