Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 503 for “"Geiger"”
-
The geiger counter
Experimental work was done to determine a satisfactory method of making counters to be used in future research work, to develop a means of testing them, and to find a counter circuit which could be used in connection with this work and for demonstration work.
-
The neutron sensitivities of Geiger-Müller counters
… to neutrons. The latter instrument is often a Geiger-Müller (G-M) counter. Although its neutron sensitivity (kᵤ) is low, it must be measured for accurate dose determinations. Previous u measurements of the neutron sensitivities of such counters have not always been in good agreement. In the …
-
A geiger counter detector for gas chromatography
Electronic Thesis or Dissertation
-
Characteristics of a spherical Geiger-Muller tube.
<p>http://www.worldcat.org/oclc/1041807379</p>
-
Detekce ionizujícího záření pomocí Geiger-Müllerova detektoru
… principy, konkrétně pak měření pomocí Geiger Mullerových detektorů. Druhá část práce obsahuje návrh obvodu zapojení s Geiger Mullerovou trubicí a obvodů zpracovávajícími získaný signál z detektoru. Dále jsou zde vyhodnoceny výsledky experimentálně získané na zařízení zkonstruovaném dle …
-
A transister quenching circuit for Geiger counter tubes
… to a basic problem inherent in the operation of Geiger-Mueller counting tubes, that is, reduction of the insensitive time, or “dead time”, following the discharge. Many researchers, using various quenching gases for internal quenching and various vacuum tube circuits for external quenching, have …
-
The sensitive surface of Geiger Muller counter tubes
[No abstract available]
-
Calibration of a Liquid Scintillator with Geiger-Mueller Counters
… in the density determinations and, since the Geiger tube threshold is much lower, to calibrate the liquid scintillator so that it is capable to determining the absolute particle density with greater accuracy.
-
Characterisation and Simulation of Linear and Geiger Mode Avalanche Photodiodes
Al0.85Ga0.15As0.56Sb0.44 is a wide bandgap material latticed matched to InP. Narrow devices from the literature show a very low excess noise factor, suggesting a wide disparity between the impact ionisation coefficients. In this work, a 600 nm pin is experimentally characterised for …
-
Experiments on the Life of Self-Quenching Geiger Mueller Counters
Because of the several superior properties of counters containing organic vapor as a quenching agent, it is desirable to extend the life of such counters. It is, therefore, of interest to determine the relative importance of factors which limit their useful life. It is also worthwhile to further …
-
A Study of the Response of the Geiger Counter Detector
Electronic Thesis or Dissertation
-
Beta dose rate evaluations with a Geiger-Mueller pancake detector
… dermis from external beta (β) emitters with a Geiger-Mueller (GM) pancake detector have been investigated through experimental evaluation. First, dose rates were measured for two separate groups of sources by use of an extrapolation chamber on the first group and by use of the computer code …
-
An Experimental Investigation of the Dead Time of Geiger-Mueller Counters
… and precise experiments are being performed with Geiger Counters, especially in cosmic ray research, the resolving power of these instruments assumes an ever increasing importance. With the present perfection of electronic circuitry, this resolving time has become largely a function of the dead …
-
Der „Discursus medicus et politicus“ von Tobias Geiger (1656). Edition und Kommentar
Der „Discursus medicus et politicus“ von Tobias Geiger ist eine Handschrift aus dem Jahr 1656. Als eine Art Lebensbericht stellt das Werk ein Plädoyer für die Chirurgie als wichtigen Bestandteil der Medizin dar. Tobias Geiger skizziert nicht nur einen „rechten medicus“ in „tempore pacis, belli et …
-
Feasibility of Geiger-mode avalanche photodiodes in CMOS standard technologies for tracker detectors
… This thesis presents the development of a GAPD (Geiger-mode Avalanche PhotoDiode) pixel detector aimed mostly at particle tracking at future linear colliders. GAPDs offer outstanding qualities to meet the challenging requirements of ILC and CLIC, such as an extraordinary high sensitivity, …
Page 1 of 26