Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"Geiger counter"”.

  1. The geiger counter

    … to determine a satisfactory method of making counters to be used in future research work, to develop a means of testing them, and to find a counter circuit which could be used in connection with this work and for demonstration work.

    vt Repository record for The geiger counter (opens in a new tab)

  2. Geiger Counter Characteristics

    uiuc Repository record for Geiger Counter Characteristics (opens in a new tab)

  3. A geiger counter detector for gas chromatography

    Electronic Thesis or Dissertation

    alabama Repository record for A geiger counter detector for gas chromatography (opens in a new tab)

  4. A transister quenching circuit for Geiger counter tubes

    … to a basic problem inherent in the operation of Geiger-Mueller counting tubes, that is, reduction of the insensitive time, or “dead time”, following the discharge. Many researchers, using various quenching gases for internal quenching and various vacuum tube circuits for external quenching, have …

    unm Repository record for A transister quenching circuit for Geiger counter tubes (opens in a new tab)

  5. A Study of the Response of the Geiger Counter Detector

    Electronic Thesis or Dissertation

    alabama Repository record for A Study of the Response of the Geiger Counter Detector (opens in a new tab)

  6. Electron emission from aluminum as a result of plastic strain

    Aluminum was strained in tension under a Geiger counter. Electron emission associated with plastic deformation and subsequent delayed emission was observed. The specimens were illuminated during both the growth and decay cycles. The emission rate, dN/dt, increased with time, to measured from the …

    rice Repository record for Electron emission from aluminum as a result of plastic strain (opens in a new tab)

  7. The study of beta-gamma decay schemes using proportional counters

    … a source of beta-particles placed outside a Geiger counter, but show marked disagreement with those which made use of a source inside a Geiger counter. Chapter 8 describes a series of experiments aimed at explaining this disagreement between the two types of Geiger counter measurement. This …

    glasgow Download PDF for The study of beta-gamma decay schemes using proportional counters (opens in a new tab)

  8. An Experimental Investigation of the Dead Time of Geiger-Mueller Counters

    … and precise experiments are being performed with Geiger Counters, especially in cosmic ray research, the resolving power of these instruments assumes an ever increasing importance. With the present perfection of electronic circuitry, this resolving time has become largely a function of the dead …

    unm Repository record for An Experimental Investigation of the Dead Time of Geiger-Mueller Counters (opens in a new tab)

  9. The primary specific ionization in gases of positrons and electrons II

    … utilizing the dependency of the efficiency of a Geiger counter upon the primary ionization of a counted particle, the mimimum primary specific ionization of electrons in several gases has been determined. The values obtained are: (1) Gas (2) ion pairs/centimeter/atmosphere Helium 5.47 ± 0.09 Neon …

    ubc Repository record for The primary specific ionization in gases of positrons and electrons II (opens in a new tab) Download PDF for The primary specific ionization in gases of positrons and electrons II (opens in a new tab)

  10. The Correlation Between Electrical Pulses and Light Flashes in a Proportional Counter.

    A proportional counter is a device used to measure the energy spectra of charged particles and photons. The charged particle ionizes the gas molecules along its path. In the presence of a strong electric field, the electrons and ions are swept toward the collecting electrodes. The electric field …

    uab Repository record for The Correlation Between Electrical Pulses and Light Flashes in a Proportional Counter. (opens in a new tab)

  11. Studies on the crystallinity of wood cellulose fibres by X-ray methods.

    … of the X-ray diffraction pattern. In method B a Geiger-counter X-ray spectrometer was used and the crystallinity ratio of holocellulose was evaluated from the (101 +101¯) combination peak. It was found that the apparent crystallinity of wood pulp and holocellulose prepared from normal western …

    ubc Repository record for Studies on the crystallinity of wood cellulose fibres by X-ray methods. (opens in a new tab) Download PDF for Studies on the crystallinity of wood cellulose fibres by X-ray methods. (opens in a new tab)

  12. Towards Quantum Computing for Audio and Music Expression

    … culminated with one of the demonstrations - "Geiger-Counter Effect" (GCE) - being integrated into two artistic processes, which explored the juxtaposition of quantum measurements with early analog music aesthetics. The first became an acousmatic study, "Rasgar, Saber", whereas the second …

    plymouth Repository record for Towards Quantum Computing for Audio and Music Expression (opens in a new tab)

  13. The Crystal Structure of Some Organic Acids

    … carried out with both visually estimated and Geiger-counter measured intensities and the results obtained with each are compared. 11-amino-undecanoic acid hydrobromide is monoclinic, space group A2/a, with eight molecules per unit cell. The atomic coordinates have been derived from a study of …

    glasgow Download PDF for The Crystal Structure of Some Organic Acids (opens in a new tab)

  14. Radiochemical studies of neutron induced fission in heavy nuclides

    … out using an end-window gas-flow β-proportional counter for solid, and a gas Geiger-counter for gaseous samples.

    kent Download PDF for Radiochemical studies of neutron induced fission in heavy nuclides (opens in a new tab)

  15. An investigation of the deformation textures of cobalt

    … using a modification of the Schulz-Decker Geiger counter technique. Pole figures of the (1011), (0001) and (1010) planes were constructed. Also, a study of the microhardness of cobalt was made. Microhardness tests were performed on various cobalt structures, in both the cold rolled and …

    must-thes Repository record for An investigation of the deformation textures of cobalt (opens in a new tab)

  16. First multi-year muography of Etna Volcano

    … the same site. He took this measurement with a Geiger counter and, therefore, he wasn't able to image the density structure. A milestone in the development of muography - or muon radiography - is the famous experiment of L. Alvarez in 1970. He attempted to use spark chambers with digital readout …

    catania Repository record for First multi-year muography of Etna Volcano (opens in a new tab)

  17. Carbon Isotope Effects in the Decarboxylation of Oxaloacetic Acid

    … were analysed by counting measured volumes in a Geiger counter, using a simple standard technique, being derived in a manner similar to that used for k12/k13. The results of the work showed the presence of definite isotope effects. Under the reaction conditions the most important species in the …

    glasgow Download PDF for Carbon Isotope Effects in the Decarboxylation of Oxaloacetic Acid (opens in a new tab)

  18. The primary specific ionization of gases of positrons and electrons

    … in various gases which are used for filling counters and ionization chambers including hydrogen, helium, neon, xenon, methane, chlorine and other quenching vapors such as methyl chloride which may become of practical concern for counters designed to operate over a wide temperature range. …

    ubc Repository record for The primary specific ionization of gases of positrons and electrons (opens in a new tab) Download PDF for The primary specific ionization of gases of positrons and electrons (opens in a new tab)

  19. Secondary emission by positrons

    … particles was counted with a thin windowed Geiger counter. Chapter III describes the electron multiplier and the associated electronics, and discusses briefly some measurements on its performance. In Chapter IV a preliminary experiment on secondary emission without using the spectrometer is …

    glasgow Download PDF for Secondary emission by positrons (opens in a new tab)

Page 1 of 2